Return to search

Desenvolvimento de sistema microfluídico baseado em gradiente de concentração difusivo para bioprocessos = Development of microfluidic system based on diffusive concentration gradient for bioprocess / Development of microfluidic system based on diffusive concentration gradient for bioprocess

Orientadores: Lucimara Gaziola de La Torre, Reinaldo Gaspar Bastos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-25T04:50:36Z (GMT). No. of bitstreams: 1
Oliveira_AlineFurtado_M.pdf: 2165174 bytes, checksum: d3aa7acdee3edc7f222daf3f7a82f910 (MD5)
Previous issue date: 2014 / Resumo: A microfluídica é uma ciência que opera em pequenos volumes de fluídos dentro de canais em dimensões de micrômetros (10-6 m). Estes sistemas permitem controlar moléculas no espaço e no tempo, gerando resultados rápidos e confiáveis num sistema precisamente controlado e capaz de mimetizar ambientes celulares. Os dispositivos microfluídicos apresentam uma diversidade de geometrias aplicáveis para diversas áreas de pesquisas, sendo que a capacidade de formar gradientes permite avaliar as condições e o desempenho celular microbiano. Assim, este trabalho teve como objetivo desenvolver dispositivos microfluídicos capazes de formar gradiente de concentração difusivo e investigar sua aplicabilidade em bioprocessos. Diante disso, foram propostos três modelos de dispositivos usando materiais biocompatíveis: (i) dispositivo em base de vidro, denominado de Vidro-vidro; (ii) em base de vidro e poli dimetilsiloxano (PDMS), chamado de Vidro-PDMS e (iii) vidro e PDMS modificado quimicamente para tornar a superfície hidrofílica, Vidro-mPDMS. Os três dispositivos foram avaliados quanto à capacidade de formação de gradiente de concentração difusivo, os quais apresentaram um perfil linear. Além disso, validou-se o estudo do comportamento de Saccharomyces cerevisiae ATCC 7754 num gradiente de concentração de glicose de 0 a 40 g/L de glicose, sendo usado o dispositivo vidro-vidro. Foi observado que houve crescimento de células ao longo das câmaras microfluídicas, e isso possibilitou na determinação de parâmetros cinéticos, os quais não apresentaram diferença estatisticamente significativa com o cultivo em batelada convencional. As condições da microfluídica possibilitaram também a determinação da cinética de Monod, usando menores intervalos de gradiente. Portanto, este dispositivo microfluídico mostrou-se uma ferramenta com potencial para investigar comportamento celular frente à diferença de concentração e contribuirá para a otimização de bioprocessos através da determinação de parâmetros cinéticos / Abstract: Microfluidic is a science that operates in small amounts of fluids inside channels in dimensions of micrometers (10-6 m). These systems allow the precise control of molecules in space and time, generating fast and reliable results and it can also be used to mimics environment cellular . Microfluidic devices can be produced in diversity of geometries, it can be applied in several scientific areas and especially the formation of concentration gradients can be used to evaluate conditions and performance of microbial cell. Therefore, this work had the objective to develop microfluidic devices that are able to generate diffusive concentration gradients and investigate their applicability in bioprocesses. In this context, we propose three models of microfluidics devices using biocompatible materials: (i) Glass-based device, named glass-glass; (ii) glass and poli dimetilsiloxane (PDMS) based device, Glass-PDMS and (iii) glass and chemically modified PDMS (hydrophilic surface), Glass-mPDMS. The three devices were evaluated by their capacity of generating difusive concentration gradient, demonstrating linear concentration profile. Furthermore, the behavior of Saccharomyces cerevisiae ATCC 7754 inside of glucose concentration gradient ranging from 0 to 40 g/L were validated, using the glass-glass device . It was observed that cell growth along the microfluidic chambers, having determined the kinetic parameters, which was considered statistically similar to conventional batch cultivation. Conditions of microfluidics also allowed determination of the Monod kinetic, using smaller intervals gradient Therefore, the use of concentration gradient in microfluidic device is a potential tool for investigate of microbial cell behavior against the concentration difference and it can contribute to the optimization of bioprocesses through the determination of kinetic parameters / Mestrado / Desenvolvimento de Processos Biotecnologicos / Mestra em Engenharia Química

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/266097
Date25 August 2018
CreatorsOliveira, Aline Furtado, 1989-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Bastos, Reinaldo Gaspar, Torre, Lucimara Gaziola de la, 1971-, Cunha, Rosiane Lopes da, Lancellotti, Marcelo
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Química, Programa de Pós-Graduação em Engenharia Química
Source SetsIBICT Brazilian ETDs
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format97 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0211 seconds