Return to search

Influência da proximidade entre o mini-implante e as raízes dentárias sobre o grau de estabilidade / Influence of miniscrew dental root proximity on the stability degree

O objetivo deste trabalho foi avaliar a influencia da proximidade entre miniimplantes autoperfurantes e as raizes dentarias sobre a estabilidade destes dispositivos de ancoragem. A amostra consistiu de 40 mini-implantes inseridos entre as raizes do primeiro molar e segundo pre-molar superiores de 21 pacientes, como recurso de ancoragem para retracao anterior. A largura do septo no local de insercao (LSI) e a menor distancia da cabeca do mini-implante a raiz dentaria (MDR) foram mensuradas nas 40 radiografias pos-cirurgicas. Sob este aspecto, os miniimplantes foram divididos em duas categorias de grupos: de acordo com a largura do septo no local de insercao, grupos G1L (LSI3mm) e G2L (LSI>3mm), e de acordo com a proximidade do mini-implante a raiz adjacente, grupos G1P (MDR0mm) e G2P (MDR>0mm). A estabilidade dos mini-implantes foi avaliada mensalmente pela quantificacao do grau de mobilidade, e a partir desta variavel foi calculada a proporcao de sucesso. Tambem foi avaliada a influencia das seguintes variaveis sobre o grau de estabilidade: caracteristica do tecido mole no local de insercao, o grau de sensibilidade, a quantidade de placa, a altura de insercao e o periodo de observacao. As duas categorias de grupos foram comparadas quanto ao grau de mobilidade e proporcao de sucesso por meio do teste de Mann-Whitney e do teste Exato de Fisher, respectivamente. Adicionalmente, avaliou-se a influencia das demais variaveis sobre a estabilidade deste sistema de ancoragem atraves do teste t e do teste do Qui-quadrado. Os resultados obtidos demonstraram que não houve diferenca estatisticamente significante para o grau de mobilidade e proporção de sucesso entre os mini-implantes inseridos em septos do grupo G1L e G2L. A proximidade entre os mini-implantes avaliados e as raizes dentarias adjacentes (grupos G1P e G2P) tambem nao influenciou na estabilidade e proporcao de sucesso deste sistema de ancoragem. A proporcao de sucesso total encontrada foi de 90% e nenhuma variavel demonstrou estar relacionada ao insucesso dos miniimplantes. No entanto, observou-se maior sensibilidade nos pacientes cujos miniimplantes apresentavam mobilidade, e que a falha destes dispositivos de ancoragem ocorria logo apos sua insercao. / The purpose of this study was to evaluate the influence of the proximity between self-drilling miniscrews and dental roots on the stability degree. The sample consisted of 40 miniscrews inserted in the interradicular septum between maxillary second premolars and first molars to provide skeletal anchorage for anterior retraction. The forty post-surgical radiographs were used to measure the septum width in the insertion site (SWI) and the smallest distance between miniscrew head and dental root (SDR). In this regard, the miniscrews were divided in two categories of groups: according to the septum width in the insertion site, groups G1W (SWI 3mm) and G2W (SWI>3 mm), and according to the miniscrew dental root proximity, groups G1P (SDR0mm) and G2P (SDR>0mm). The mobility degree (MD) was monthly quantified to determine miniscrew stability, and the success rate of these devices was calculated. This study also evaluated the influence of following variables on the stability degree: soft tissue characteristics in the insertion site (attached gingiva, mucogingival junction and alveolar mucosa), sensitivity degree during miniscrew load, plaque amount around miniscrew, insertion height, and total evaluation period. All the groups were compared regarding mobility degree and success rate using t test and Fisher exact test, respectively. The results showed no significant difference in mobility degree and success rate between groups G1W and G2W. The miniscrew dental root proximity did not influence the stability and success rate of this anchorage system when G1P and G2P were compared. The total success rate found was 90% and no variable was associated with the miniscrew failure. Nevertheless, the results showed that greater patient sensitivity degree was associated to the miniscrews mobility and the failure of these anchorage devices happened in a short time after their insertion.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-29052009-111711
Date12 March 2009
CreatorsMariana Pracucio Gigliotti
ContributorsGuilherme dos Reis Pereira Janson, Arnaldo Pinzan, Fabrício Pinelli Valarelli
PublisherUniversidade de São Paulo, Odontologia (Ortodontia e Odontologia em Saúde Coletiva), USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0016 seconds