This master thesis gives an account for various aeration schemes that are utilized in conventional activated sludge treatment process in a wastewater treatment plant. By altering between different aeration schemes, the project aimed at reducing energy consumption along with maintaining the treatment performance at the plant. A series of experiments on the treatment performance over several different aeration schemes thus has been conducted on site at Solviken in Mora, Sweden. The project is basically a case study where no parameters were manually controlled except for the aeration schemes at the plant. Energy consumption reduction is logically relative to the ratio between aeration and non-aeration intervals. Several criteria were tested in regards to the treatment performance, including pH value, organic matters, phosphorus substances and microorganisms. The study has come up with a superior aeration scheme for the plant, as well as indicated processes that can be improved at the plant.
Identifer | oai:union.ndltd.org:UPSALLA1/oai:DiVA.org:kth-190742 |
Date | January 2016 |
Creators | Li, Wen |
Publisher | KTH, Mark- och vattenteknik |
Source Sets | DiVA Archive at Upsalla University |
Language | English |
Detected Language | English |
Type | Student thesis, info:eu-repo/semantics/bachelorThesis, text |
Format | application/pdf |
Rights | info:eu-repo/semantics/openAccess |
Relation | TRITA-LWR Degree Project, 1651-064X ; 2016:15 |
Page generated in 0.0014 seconds