Return to search

Efeitos de diferentes freqüências e amplitudes de vibração unilateral do tendão calcâneo na orientação postural e no reflexo H em humanos / Effects of Achilles tendon vibration of different frequencies and amplitudes on postural orientation and H reflex in humans

Uma vibração aplicada a um tendão muscular aumenta a freqüência de disparos de aferentes, como os de fusos neuromusculares Ia e II, cujas terminações afetam circuitos da medula espinhal e com isto podem influenciar o controle motor. O objetivo deste estudo foi analisar o efeito de vibrações a duas freqüências (15 e 80Hz) e amplitudes de 1 e 2,5mm aplicadas ao tendão calcâneo direito sobre o sistema de controle postural e sobre a circuitaria neural associada a reflexos monosinápticos da perna. A hipótese era de que a vibração de alta freqüência ativasse preferencialmente os aferentes de fuso neuromuscular de tipo Ia enquanto a vibração a 15 Hz ativasse preferencialmente os aferentes de tipo II. Isto significaria que a vibração a 80 Hz teria forte efeito sobre o reflexo H, enquanto a vibração a 15 Hz teria um efeito significativo sobre a postura. Participaram deste estudo 14 sujeitos sãos. Na postura ereta quieta, foi realizada a aquisição do reflexo H enquanto o tendão calcâneo era vibrado. Após um intervalo de descanso, foi realizada a aquisição do Centro de Pressão (COP) tanto na direção Ântero-Posterior (AP) quanto na Médio-Lateral (ML) em paralelo à aquisição bilateral do EMG dos músculos (SO, TA, GL e GM) nas três condições (antes, durante e após a vibração do tendão calcâneo). Para os estímulos de 1 e 2,5mm realizados a 80 Hz as diferenças foram significativas em relação a todas as variáveis quando comparadas nas três condições, com exceção apenas do DP do TA e GM e, do valor médio do COP ML a 1mm. Em relação à freqüência de 15 Hz, notou-se que não houve diferenças significativas tanto no COP AP e ML quanto no DP do EMG dos músculos da perna esquerda entre as três condições. Quanto aos dados referentes ao DP dos músculos analisados na perna direita, os resultados mostraram que não houve efeitos significativos tanto ao utilizar 15Hz como 80Hz em todas as três condições. Em geral, estes dados mostraram que durante um estímulo vibratório mais forte o COP deslocouse mais para a direção posterior e lateral esquerda do sujeito. E, após interromper o estímulo, em alguns casos o COP ainda mostrava uma alteração prolongada. Em relação à amplitude média do reflexo H, para as amplitudes de vibração de 1 e 2,5 mm a 15 e 80 Hz, as análises apontaram que durante a vibração houve uma forte redução na amplitude do reflexo, sendo que em alguns casos ainda permaneceram reduzidas na condição pós-vibratória. Os resultados mostram que a vibração aplicada ao tendão calcâneo pode ser um forte estímulo à medula e capaz de alterar o controle postural, dependendo de suas características, uma vez que, com parâmetros apropriados, induziu alterações imediatas nos resultados do reflexo H, do COP e do EMG (p.e.). Porém, as alterações a vibrações aplicadas de modo a ativar seletivamente as fibras aferentes do grupo Ia e II mostraram efeitos diferenciais. Vibrações a 80Hz de frequência e a 1 e 2,5mm foram as que mais causaram alterações. A significativa ação sobre o reflexo H é compatível com o aumento da frequência de disparos dos aferentes Ia. Entretanto a forte ação sobre o COP dessas vibrações a 80 Hz sugere que os aferentes Ia podem ter uma importância maior do que a literatura recente tem preconizado, pelo menos para correções a perturbações posturais, uma vez que pode-se supor que a 80 Hz e 1 mm de amplitude os aferentes tipo II são pouco ativados. Por outro lado, a vibração a 15 Hz teve um efeito signficativo sobre o reflexo H mas sem afetar o COP, o que sugere que esta frequência consegue ativar a via Ia, causando depressão homossináptica e/ou inibição pré-sináptica dos aferentes Ia, mas sem chegar a influir no COP de forma significativa. Os resultados são interessantes do ponto de vista de aplicações em potencial para áreas como fisioterapia e reabilitação de pessoas com alterações posturais na clínica. Adicionalmente, abrem novas questões quanto às interpretações fisiológicas de vibrações a diferentes freqüências sobre o tendão calcâneo. / A vibration applied to a muscle tendon increases the firing frequency of afferents of types Ia and II innervating muscle spindles, and hence affects the spinal cord circuits and this can affect motor control. The aim of this study was to analyze the effect of vibrations of two frequencies (15 and 80Hz) and two amplitudes (1 and 2.5 mm) applied to the right Achilles tendon on the standing posture and on the H reflex. The hypothesis was that the high frequency vibration activates preferentially the Ia axons while the 15 Hz vibration activates preferentially the type II axons and hence the 80 Hz vibration would have a strong effect on the H reflex and the 15 Hz vibration would have a strong effect on posture. Fourteen subjects participated in this study. Their H reflex was acquired in the upright position while their Achilles tendon was vibrated. After an interval of rest, the center of pressure (COP) signal was acquired for both the antero-posterior (AP) and the medio-lateral (ML) directions in parallel with the acquisition of bilateral electromyograms (EMG) (SO, TA, and GL GM) in the three conditions (before, during and after the vibration of the Achilles tendon). For 1 and 2.5 mm vibrations at 80 Hz the differences were significant for all variables compared in the three conditions, except for the standard deviation (SD) of the TA and GM EMGs and the average value of COP ML for 1mm vibration. For the 15 Hz vibration, there were no significant differences in both the AP and ML COP and SD of the EMG of the left leg in the three conditions. The results for the EMG SD of the right leg showed no significant effects when using both 15Hz and 80Hz in all three conditions. These data showed that during a stronger vibratory stimulus the COP shifted more to the posterior direction and the left side of the subject. And, after stopping the stimulus, in some cases, the COP had not returned to the initial position. In relation to the mean H reflex amplitude for 1 and 2.5 mm vibrations at 15 and 80 Hz, the analysis showed that during vibration there was a stronger reduction in the amplitude of the H reflex, and in some cases the amplitude remained reduced in the post-vibratory period. The results showed that the vibration applied to the Achilles tendon can be a powerful stimulus to the spinal cord and capable of altering the postural control. The effects depended on the vibration features, since, with appropriate parameters, it led to immediate changes in the results of the H reflex, the COP and left leg EMG. However, 80 Hz vibration (1 and 2.5 mm) was the one that caused the largest changes both on COP and H reflex amplitude. The significant action on the H reflex is consistent with the increased frequency of firing of Ia afferent. However the strong action on the COP of vibrations at 80 Hz suggests that the Ia afferents may have a greater importance than what the recent literature has suggested, at least for postural corrections to disturbances, since it can be assumed that the type II afferents are little activated at 80 Hz and 1 mm amplitude. Furthermore, vibration at 15 Hz had a significant effect on the H reflex without affecting the COP, suggesting that vibrations at this frequency can activate Ia afferents, causing homosynaptic depression and / or presynaptic inhibition of Ia afferents, but without influencing the COP significantly. The results are interesting from the standpoint of potential applications to areas such as physical therapy and rehabilitation of patients in the clinic. Additionally, they raise new questions about the physiological mechanisms behind vibratory stimuli applied at different frequencies on the Achilles tendon.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-16042010-104819
Date30 March 2010
CreatorsSabrina Tiago Pedão
ContributorsAndre Fabio Kohn, Gilberto Mastrocola Manzano, Eugênia Casella Tavares de Mattos
PublisherUniversidade de São Paulo, Neurociências e Comportamento, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0029 seconds