Return to search

Análise por impedância eletroquímica \"on-line\" de conjuntos eletrodo/membrana (MEA) de células a combustível a membrana polimérica (PEMFC) / Analysis for impedance electrochemistry \"on-line\" of membrane/electrode assemble (MEA) of protons exchange membrane fuel cells (PEMFC)

Este trabalho apresenta resultados de estudos e caracterizações de Conjuntos Eletrodo/Membrana (MEAs) de Células a Combustível a Membrana Polimérica (PEMFC). Algumas condições de operação de células e diferentes processos de produção de MEA foram investigados. A técnica de Espectroscopia de Impedância Eletroquímica (EIE) (em situ - 0 a 16 A) foi usada \"on-line\" como uma ferramenta de diagnóstico, relativa ao desempenho de célula. As medidas de EIE foram feitas através do Sistema de EIE para células a combustível FC350 (GAMRY), junto a um PC4 Potentiostato/Galvanostato e conectado à carga dinâmica (TDI) para experimentos de EIE \"on-line\" (100 mHz - 10 kHz, dU = 5 mV). MEAs com 25 cm2 de área ativa, usando eletrocatalisadores PtM/C 20 % (M = Ru, Sn ou Ni) fabricados usando o Método de Redução por Álcool (MRA). A tinta catalítica foi diretamente aplicada no Tecido de Carbono (GDL) e este prensado na membrana de Nafion® (105). MEAs usando eletrocatalisadores Pt/C e PtRu/C 20 % da E-TEK foram fabricados para comparação. Todos os cátodos foram confeccionados com Pt/C 20% da E-TEK. Foram fixadas as concentrações de metal nobre em 0,4 mg Pt.cm-2 no anodo e 0,6 mg Pt.cm-2 no catodo (E-TEK). Diagramas de Nyquist dos MEAs com Pt/C e PtRu/C da E-TEK ou PtM/C MRA apresentaram as mesmas resistências de ôhmicas para os MEAs. Este fato pode ser explicado por supressão de aglomerados durante o processo de preparação do MEA ou pela homogeneidade do eletrocatalisador ancorado ao carbono. Também pôde ser observado, a baixas densidades atuais que há uma diferença de desempenho significante entre o eletrocatalisadores da ETEK e os preparados pelo MRA. Os resultados das curvas de polarização confirmaram que PtM/C MRA apresentara um aumento de atividade para as células alimentadas com metanol e etanol. A técnica de EIE se mostrou eficiente para a avaliação do método de preparação dos MEAs e do desempenho da célula, os resultados de EIE mostraram uma coerência na escolha do modelo do circuito elétrico para os MEAs utilizando hidrogênio, metanol e etanol. Esta coerência indica que outras resistências não consideradas no modelo não são relevantes na resistência total dos MEAs. / This work reports results of studies and characterization on Membrane Electrode Assemblies (MEAs) for Proton Exchange Membrane Fuel Cell (PEMFC). Some cell operation conditions and different processes of MEA production were investigated. The Electrochemical Impedance Spectroscopy Technique (EIS) (in situ - 0 to 16 A) was used \"on-line\" as a tool for diagnosis, concerning the cell performance. The EIS measurements were carried out with a FC350 Fuel Cell EIS System (GAMRY), coupled to a PC4 Potentiostat/Galvanostat and connected to the electronic load (TDI) for \"on-line\" EIS experiments (100 mHz - 10 kHz, dU = 5 mV). MEAs with 25 cm2 surface area, using PtM/C 20% (M = Ru, Sn or Ni) electrocatalysts were manufactured using the Alcohol Reduction Process (ARP). The catalytic ink was applied directly into the Carbon Cloth (GDL) and pressed in the NafionR membrane (105). MEAs using Pt/C and PtRu/C 20% from E-TEK electrocatalysts were manufactured by comparison. All the cathodes were sprayed with Pt/C 20% from E-TEK. The noble metal concentrations used were set to 0.4 mg Pt.cm-2 at the anode and 0.6 mg Pt.cm-2 at the cathode (E-TEK). Nyquist diagrams of the MEAs with Pt/C and PtRu/C from E-TEK or PtM/C (M = Ru, Sn or Ni) ARP showed essentially the same ohmic resistances for the MEAs. This fact can be explained by suppression of agglomerates during the MEA preparation process or by the homogeneity of the anchored electrocatalysts at the carbon surface. It could also be observed, at low current densities, that there was a significant performance difference between the electrocatalysts from E-TEK and those prepared with the Alcohol Reduction Process. The polarization curves results confirmed that the PtM/C (M = Ru, Sn or Ni) ARP showed an activity increase for the methanol and ethanol fed cells. The technique of EIE was shown efficient for the evaluation of the method preparation of MEAs and the acting of the cell, the results of EIE showed coherence in the choice of the model the electric circuit for MEAs using hydrogen, methanol and ethanol. This coherence indicates that other resistances no considered in the model are not relevant in the total resistance of MEAs.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-16052012-093213
Date15 August 2007
CreatorsAntonio Rodolfo dos Santos
ContributorsMarcelo Linardi, Silvia Maria Leite Agostinho, Hercilio Gomes de Melo, Almir Oliveira Neto, Estevam Vitorio Spinacé
PublisherUniversidade de São Paulo, Tecnologia Nuclear, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0027 seconds