Return to search

Estudo quimico, macroscopico e da resistencia a flexão de placas e parafusos de titanio usados na fixação interna rigida

Orientador: Renato Mazzonetto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-24T19:18:54Z (GMT). No. of bitstreams: 1
Trivellato_AlexandreElias_M.pdf: 5510556 bytes, checksum: a3be169b860e19d10716d10b33ad4a34 (MD5)
Previous issue date: 1999 / Resumo: O objetivo deste estudo foi comparar quatro sistemas de placas e parafusos de 2,0 mm utilizados em fixação interna rígida, sendo duas marcas nacionais (Engimplan e Bucomax) e duas importadas (Synthes e W. Lorenz). Foram realizadas as seguintes análises: composição química, através de espectrometria por dispersão de energia (EDS) e espectrometria de emissão atômica (AES), macroscópico através de medidas padronizadas e de resistência à flexão. Os resultados obtidos permitem concluir que as marcas nacionais apresentaram um comportamento inferior, em relação a padronização das dimensões das placas e parafusos avaliados, influenciando nos resultados dos testes de flexão, onde estas se comportaram da mesma maneira. Entretanto, a marca comercial W. Lorenz utiliza liga de titânio-6alumínio-4vanádio para a confecção dos parafusos, fato responsável pelo melhor resultado no teste de flexão, que qualquer outra marca. Os demais parafusos e placas apresentaram, se constituídos de titânio comercialmente puro, de acordo com a EDS 'e posteriormente confirmados pela AES / Abstract: The aim of this study was to compare four 2.0 mm systems of plates and screws of used for internal rigid fixation. From them, two were Brazilian (Engimplan and Bucomax), one made in Switzerland (Synthes), and the fourth one was made in the Germany (W. Lorenz). The following analysis were done in both plates and screws: chemical analysis using Energy Dispersive Spectroscopy (EDS) and Atomical Emission Spectroscopy (AES), measurement of dimensions and bending resistance. The present results allow to conclude that both Brazilian systems evaluated showed a lower behavior in evaluation to the dimensions. The bending assay showed that Brazilian systems were similar. However, in the trademark W. Lorenz the screws are made from titanium-6aluminum-4vanadium alloy, what can be the reason for a better performance in the bending assay compared to the other three systems. The remaining plates and screws are made from titanium commercially pures as confirmed by EDS and AES / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288692
Date25 January 1999
CreatorsTrivellato, Alexandre Elias
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Mazzonetto, Renato, 1968-2011, Salata, Luiz Antonio, Passeri, Luis Augusto
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format92p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds