Introduction
76Br is of interest for in vivo PET imaging applications. Its relatively long half-life (16.1 h) allows use not only on small molecules but also proteins which have slow excretion as carrier molecules. Irradiation using a low energy proton beam (~ 20 MeV) on an enriched Cu276Se target, followed by dry distillation with thermal chromatography, is one of the best methods to obtain sufficient amounts of 76Br for clinical applications1,2. However, the thermal chromatography is plagued by poor reproducibility and appears unsuitable for automation of its production, leading us to remove the thermal chroma-tography from the dry distillation. In this investigation we employed H2O solution to collect 76Br and optimized the distillation condition using a small amount of 77Br (57.0 h). We also produced large amount of 76Br under the optimized conditions to evaluate the dry distillation method.
Material and Methods
Target preparation and dry distillation were conducted based on the methods described in previous reports1,2. To produce 77Br, Cu2natSe target was irradiated with 20 MeV proton beams (5 µA) accelerated by AVF cyclotron in the Japan Atomic Energy Agency. The following two systems were used in the dry distillation optimization studies; (1) an initial system was composed of two furnaces, a main and an auxiliary furnace. Temperature of each furnace was set at 1050 °C (main) and 200 °C (auxiliary) respectively; (2) the second system was made of one large furnace composed of heating and cooling area. Temperature of the heating area was varied from 1050 to 1120 °C. In both systems PTFE tubing, leading to a H2O solution (15 mL), was inserted into the apparatus. The irradiated target was heated under streaming Ar gas (30 mL/min.). An enriched Cu276Se target (76Se enrichment: 99.67%) was used for 76Br production. Radioactivity was measured on a high-purity germanium (HPGe) detector coupled to a multichannel analyzer. TLC analyses were conducted on Al2O3 plates (Merck) using 7:1 acetone:H2O as the eluting solvent.
Results and Conclusion
Low efficiency (33 %) of 77Br recovery was ob-served in the initial system. Distribution of radioactivity inside the apparatus showed that 35 % was trapped in the PTFE tube and the quartz tube. The recovery yield was increased up to 54 % when the auxiliary furnace was turned off, indicating that the temperature gradient inside the quartz tube is suitable to carry 77Br effectively to the H2O trap. We initially used a quartz boat to place the irradiated target in the furnace, but found that using a reusable tungsten backing was better. However, we found that recovery yield was dramatically reduced to 18 %. The studies where the temperature was varied showed that releasing efficiency was increased up to 100 % at the temperature of 1120 °C. Good recovery yield (~ 77 %) was achieved after optimizing the temperature gradient (FIG. 1b). Using the optimized setup, 76Br production runs (n = 6) have been conducted, allowing us to recover up to 39.8 MBq/µAh (EOB) of 76Br. High specific activity (~4400 GBq/µmol) was obtained in the final solution. TLC analysis showed that chemical form obtained was bromide. We concluded that the dry distillation using H2O trap is capable of providing enough high purity 76Br for clinical applications.
Identifer | oai:union.ndltd.org:DRESDEN/oai:qucosa.de:bsz:d120-qucosa-164264 |
Date | 19 May 2015 |
Creators | Watanabe, Sh., Watanabe, Sa., Ohshima, Y., Sugo, Y., Sasaki, I., Hanaoka, H., Ishioka, N. S. |
Contributors | Japan Atomic Energy Agency, Takasaki, Gunma, Japan, Medical Radioisotope Application Group, Helmholtz-Zentrum Dresden - Rossendorf,, Chiba University Graduate School of Pharmaceutical, Chiba, Japan , |
Publisher | Helmholtz-Zentrum Dresden - Rossendorf |
Source Sets | Hochschulschriftenserver (HSSS) der SLUB Dresden |
Language | English |
Detected Language | English |
Type | doc-type:conferenceObject |
Format | application/pdf |
Source | WTTC15 |
Page generated in 0.0023 seconds