Orientador: Flavio Vasconcelos da Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-07T21:48:37Z (GMT). No. of bitstreams: 1
Santos_ReginaLuciadeAndradedos_M.pdf: 2611251 bytes, checksum: 3243445f76398670aa1390de96139a08 (MD5)
Previous issue date: 2006 / Resumo: Com o advento do sistema digital em rede (fieldbus) e a ampla divulgação das vantagens da utilização desta nova tecnologia aliada ao uso de instrumentos inteligentes, tornou-se inquestionável a melhora no desempenho e confiabilidade dos dados obtidos através deste sistema para o controle em novas plantas industriais ou em sistemas destinados à pesquisa tecnológica. Estratégias de controle clássicas, tais como o controle PID (proporcional ¿ integral ¿ derivativo), são largamente utilizadas no setor industrial devido à sua robustez e facilidade de implementação, embora limitações possam ser observadas quanto à adequação destes controladores às não-linearidades presentes nos sistemas reais. A utilização dos controladores adaptativos (baseados em parâmetros variáveis) permite tais adequações respeitando a dinâmica dos sistemas. Nas últimas décadas tem-se notado um significante aumento na aplicação da teoria de controladores avançados, entretanto, a sua utilização no setor produtivo ainda é incipiente. Apresenta-se, neste trabalho, uma automação híbrida alternativa para monitoramento, em tempo real, das variáveis de processo de um sistema para precipitação da enzima bromelina com supervisão, em tempo real, das condições do processo sob diferentes perturbações na carga, usando estratégia SISO em arquitetura de rede Fieldbus. Além disso, por se tratar de um bioprocesso, em batelada, as não linearidades e o aspecto essencialmente transiente da operação evidenciam a inevitável prioridade na aplicação dos controladores avançados, uma vez que os controladores convencionais possuem ação limitada neste tipo de sistema, garantindo a qualidade final da enzima obtida. Através dos resultados obtidos pôde-se comprovar a que ambos os controladores PID convencional e adaptativo tiveram um bom desempenho na manutenção da temperatura, porém houve um melhor desempenho com o PID adaptativo como foi observado pelos parâmetros de desempenho ITAE, overshoot e tempo de subida / Abstract: Fieldbus technology and intelligent sensors/actuators are increasingly being used in automated systems, opening up new possibilities for distributed control structures, mainly in new plants and research applications where is very important to have a flexible automation structure to different plant conditions with huge flow of information. Significant improvements have been seen in advanced controllers over the last years. However, linear PID controller is still applied extensively in industrial practice. The reason lies in its robustness and well-Known control design and implementation, although assumptions, simplifications, or lumping parameters are often made to build a mathematical model that may be far from the real situation. The behavior of most physical systems, especially bath systems, is nonlinear. Linear control may be effective for local operation, but is inadequate for controlling operations over a broad range. Adaptive controllers are nonlinear systems, which are commonly based on linear control theory. Despite many publications in the last decades illustrating advantages of adaptive controllers, this Kind of control is still not so common in industrial practice. One of reasons for the low incidence of application is relative difficulty to implement this controller. In this study, a comparative experimental design and tuning of conventional PID and adaptive PID controllers was developed for a pilot plant batch to precipitate of enzyme bromelain, using SISO strategy in fieldbus network architecture. The system was applied to the on line control of temperature of the extraction tank, involving a performance control analysis, under different load disturbances. From the results of this work, both controllers were considered suitable to control the temperature of the fedbatch tank. Nevertheless, the closed loop performance was improved under adaptive PID controller: the performance index ITAE, the overshoot and the rise time decreased. / Mestrado / Sistemas de Processos Quimicos e Informatica / Mestre em Engenharia Química
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/266163 |
Date | 10 November 2006 |
Creators | Santos, Regina Lucia de Andrade dos |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Silva, Flávio Vasconcelos da, 1971-, Fileti, Ana Maria Frattini, Bertevello, Luiz Carlos, Umezu, Claudio Kiyoshi |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Química, Programa de Pós-Graduação em Engenharia Química |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 86f. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0031 seconds