Since uncertainty exists inevitably in control systems, it is questionable whether the controller, designed to compensate a nominal plant well, still guarantees the criteria of robust stability and robust H¡Û performance for the perturbed plant. In this thesis, controller parameters tuning based on the sensitivity concept of structured singular value, called £g-sensitivity, will be adopted to do the parameter adjustment so that, when the influence of uncertainty is considered, the robust stability and robust performance properties of the nominal closed-loop system will be preserved. In view of the time consuming effect of numerical computation and the misjudgment due to discontinuity problem involved in the £g-sensitivity analysis, this thesis proposes the sensitivity concept of skewed structured singular value, called £h-sensitivity, to remedy these drawbacks. Finally, the feasibility of the £h-sensitivity based controller parameters tuning technique is verified by the simulation results of two examples.
Identifer | oai:union.ndltd.org:NSYSU/oai:NSYSU:etd-0816101-210353 |
Date | 16 August 2001 |
Creators | Lien, I-Sheng |
Contributors | Chih-Chiang Cheng, Li Lee, Cheng-Chih Kao |
Publisher | NSYSU |
Source Sets | NSYSU Electronic Thesis and Dissertation Archive |
Language | Cholon |
Detected Language | English |
Type | text |
Format | application/pdf |
Source | http://etd.lib.nsysu.edu.tw/ETD-db/ETD-search/view_etd?URN=etd-0816101-210353 |
Rights | unrestricted, Copyright information available at source archive |
Page generated in 0.0019 seconds