This paper deals with CUSUM tests for monitoring
of intensity parameter of a Poisson process if this
process can be observed in a restricted manner only at pregiven
equidistant time points. In this case the process can
be monitored by means of a CUSUM test for the parameter
of a corresponding Poisson distribution.
For rational reference parameter values the computation
of average run length is reduced to that of solving of a
system of simultaneous linear equations. The performance
of obtained CUSUM tests is discussed by means of corresponding
examples.