In modern heat transfer, shape and geometric optimisation are new considerations in the evaluation of thermal performance. In this research, we employed constructal theory and design to present three-dimensional theoretical and numerical solutions of conjugate forced convection heat transfer in heat generating devices with cooling channels of different cross-sectional shapes. In recent times, geometric configurations of cooling channel have been found to play an important role in thermal performance. Therefore, an efficient ways of optimally designing these cooling channels shapes is required. Experimentation has been extensively used in the past to understand the behaviour of heat removals from devices. In this research, the shapes of the cooling channels and the configurations of heat-generating devices were analytically and numerically studied to minimise thermal resistance and thus illustrate cooling performance under various design conditions. The cooling channels of five different cross-sectional shapes were studied: Circular, square, rectangular, isosceles right triangular and equilateral triangular. They were uniformly packed and arranged to form larger constructs. The theoretical analysis is presented and developed using the intersection of asymptotes method. This proves the existence of an optimal geometry of parallel channels of different cross-sectional shapes that penetrate and cool a volume with uniformly distributed internal heat generation and heat flux, thus minimising the global thermal resistance. A three-dimensional finite volume-based numerical model was used to analyse the heat transfer characteristics of the cross-sectional shapes of various cooling channels. The numerical computational fluid dynamics (CFD) package recently provided a more cost-effective and less time-consuming means of achieving the same objective. However, in order to achieve optimal design solutions using CFD, the thermal designers have to be well experienced and carry out a number of trial-and-error simulations. Unfortunately, this can not always guarantee an accurate optimal design solution. In this thesis a mathematical optimisation algorithm (a leapfrog optimisation program and DYNAMIC-Q algorithm) coupled with numerical CFD was employed and incorporated into the finite volume solver, –FLUENT, and grid (geometry and mesh) generation package, – GAMBIT to search and identify the optimal design variables at which the system would perform optimally for greater efficiency and better accuracy. The algorithm was also specifically designed to handle constraint problems where the objective and constraint functions were expensive to evaluate. The automated process was applied to different design cases of cooling channels shapes. These cooling channels were embedded in a highly conductive solid and the peak temperature was minimised. The trend and performance of all the cooling channel shapes cases studied were compared analytically and numerically. It was concluded that an optimal design can be achieved with a combination of CFD and mathematical optimisation. Furthermore, a geometric optimisation of cooling channels in the forced convection of a vascularised material (with a localised self-cooling property subjected to a heat flux) was also considered. A square configuration was studied with different porosities. Analytical and numerical solutions were provided. This gradient-based optimisation algorithm coupled with CFD was used to determine numerically the optimal geometry that gave the lowest thermal resistance. This optimiser adequately handled the numerical objective function obtained from numerical simulations of the fluid flow and heat transfer. The numerical results obtained were in good agreement with results obtained in the approximate solutions based on scale analyses at optimal geometry dimensions. The approximate dimensionless global thermal resistance predicted the trend obtained in the numerical results. This shows that there were unique optimal design variables (geometries) for a given applied dimensionless pressure number for fixed porosity. The results also showed that the material property had a significant influence on the performance of the cooling channel. Therefore, when designing the cooling structure of vascularised material, the internal and external geometries of the structure, material properties and pump power requirements would be very important parameters to be considered in achieving efficient and optimal designs for the best performance. Finally, this research investigated a three-dimensional geometric optimisation of conjugate cooling channels in forced convection with an internal heat generation within the solid for an array of cooling channels. Three different flow orientations based on constructal theory were studied numerically- firstly, an array of channels with parallel flow; secondly, an array of channels in which flow of every second row was in a counter direction and finally, an array of channels in which the flow direction in every channel was opposite to that of previous channel. The geometric configurations and flow orientations were optimised in such a way that the peak temperature was minimised subject to the constraint of fixed global volume of solid material. The optimisation algorithm coupled with CFD was also used to determine numerically the optimal geometry that gave the lowest thermal resistance. The use of the optimisation algorithm coupled with the computational fluid dynamics package; render the numerical results more robust with respect to the selection of optimal structure geometries, internal configurations of the flow channels and dimensionless pressure difference. / Thesis (PhD(Eng))--University of Pretoria, 2012. / Mechanical and Aeronautical Engineering / unrestricted
Identifer | oai:union.ndltd.org:netd.ac.za/oai:union.ndltd.org:up/oai:repository.up.ac.za:2263/25484 |
Date | 12 June 2013 |
Creators | Olakoyejo, O.T. (Olabode Thomas) |
Contributors | Meyer, Josua P., Bello-Ochende, Tunde, olakoyejo@yahoo.com |
Publisher | University of Pretoria |
Source Sets | South African National ETD Portal |
Detected Language | English |
Type | Thesis |
Rights | © 2012 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. |
Page generated in 0.0028 seconds