Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-04T17:53:19Z
No. of bitstreams: 1
leonardocoelhopertence.pdf: 1941969 bytes, checksum: f7f3753c2825d1dfd1c727018b9807ec (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T16:21:57Z (GMT) No. of bitstreams: 1
leonardocoelhopertence.pdf: 1941969 bytes, checksum: f7f3753c2825d1dfd1c727018b9807ec (MD5) / Made available in DSpace on 2016-07-13T16:21:58Z (GMT). No. of bitstreams: 1
leonardocoelhopertence.pdf: 1941969 bytes, checksum: f7f3753c2825d1dfd1c727018b9807ec (MD5)
Previous issue date: 2012-06-15 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo foi investigar os efeitos da aplicação contrapesos no VO2, FC e PE durante a pedalada unilateral. Participaram do estudo 11 ciclistas (31 ± 8 anos, 176 ± 8 cm, 70,6 ± 10,8 Kg, 22,7 ± 2,1 Kg.m2, e 64 ± 9 ml.kg-1.min-1). Os ciclistas compareceram ao laboratório em 7 dias diferentes. No primeiro dia, foram submetidos à avaliação antropométrica, a um teste de pedalada bilateral (PB) em carga constante nas potências de 60 e 100 W e cadências de 60, 75 e 90 rpm, seguido por um teste de PB incremental. Do segundo ao sétimo dia, foram realizados os testes de pedalada unilateral (PU) com o membro inferior dominante utilizando os contrapesos de 2,5 kg ou 5,0 kg ou sem contrapeso nas potências de 60 e 100 W. O VO2, FC e PE foram medidos em todos os testes de PB e PU. Os dados foram apresentados por média ± desvio padrão. Foi utilizada ANOVA para medidas repetidas e posteriormente a plotagem de Bland-Altman para verificar a concordância entre a PU e a PB. Na potência de 60 W, a PU pode ser executada sem a necessidade de aplicação de contrapesos. Na potência de 100 W, durante a PU, tanto o contrapeso de 2,5 quanto o de 5,0 Kg equipararam o VO2 com o da PB, independentemente da cadência utilizada. Para a frequência cardíaca e percepção do esforço, o uso de contrapesos na potência de 60 W mostrou-se efetivo em reproduzir a PB. Entretanto, na potência de 100 W, a aplicação de contrapesos tanto para a frequência cardíaca quanto para a percepção do esforço, não foi um método eficaz para tornar a PU similar a PB. / The aim of this study was to investigate the effects of applying counterweight on VO2, HR and RPE during single-leg cycling. The study included 11 cyclists (31 ± 8 years, 176 ± 8 cm, 70.6 ± 10.8 kg, BMI 22.7 ± 2.1 and 64 ± 9ml.kg-1.min-1). The experimental design was divided into 7 different days. On the first day, the volunteers were submitted to anthropometric evaluation, a double-leg test of cadences in powers of 60 and 100 W and cadences of 60, 75 and 90 rpm followed by a double-leg incremental test. From the second to the seventh day, were performed single-leg tests with dominant leg using the counterweight 2.5 kg or 5kg or noncounterweight and in the 60 W and 100 W powers. The VO2, HR and RPE values were measured in all tests. The data were presented by mean ± standard deviation. We used, ANOVA for repeated measures and subsequently the Bland-Altman plot to assess the agreement between single-leg and double-leg cycling. The PU60 was not different from PB60 from the point of view of oxygen uptake. At 100 W workload, both the counterweights 2.5 Kg and 5,0 Kg matched the oxygen uptake, enabling single-leg cycling to be performed with the same metabolic cost of double-leg cycling. However, at 100 W workload, the counterweight apparatus was not effective to make similar single-leg and double-leg cycling based on HR and RPE comparisons.
Identifer | oai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/1983 |
Date | 15 June 2012 |
Creators | Pertence, Leonardo Coelho |
Contributors | Lima, Jorge Roberto Perrout de, Vianna, Jeferson Macedo, Guglielmo, Luiz Guilherme Antonacci |
Publisher | Universidade Federal de Juiz de Fora, Programa de Pós-graduação em Educação Física, UFJF, Brasil, Faculdade de Educação Física |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0034 seconds