Deep foundations, including driven piles, are used to support vertical loads of structures and applied lateral forces. Many pile supported structures, including bridges, are subjected to large lateral loads in the form of wind, wave, seismic, and traffic impact loads. In many practical situations, structures subjected to lateral loading are located near or in excavated and fill slopes or embankments. Full-scale research to examine the effects of soil slope on lateral pile capacity is limited. The purpose of this study is to examine the effects on lateral capacity of piles located in or near cohesionless soil slopes.
A full-scale lateral load testing program was undertaken on pipe piles in a cohesionless soil at Oregon State University. Five piles were tested near a 2H:1V test slope and located between 0D to 8D behind the slope crest, where D is the pile diameter. Two vertical baseline piles and three battered piles were also tested in level ground conditions. The cohesionless backfill soil was a well-graded material with a fines content of less than 10% and a relative compaction of 95%, meeting the Caltrans specification for structural backfill.
Data collected from the instrumented piles was used to back calculate p-y curves, load-displacement curves, reduction factors, and load resistance ratios for each pile. The effects of slope on lateral pile capacity are insignificant at displacements of less than 2.0 inches for piles located 2D and further from the crest. For pile located at 4D or greater from the slope crest, the effect of slope is insignificant on p-y curves. A simplified p-multiplier design procedure derived from back-calculated p-y curves is proposed to account for the effects of soil slope.
Comparisons of the full-scale results were made using proposed recommendations from the available literature. Lateral resistance ratios obtained by computer, centrifuge, and small scale-models tend to be conservative and overestimate the effects of slope on lateral capacities. Standard cohesionless p-y curve methods slightly over predict the soil resistance at very low displacements but significantly under predict the ultimate soil resistance. Available reduction factors from the literature, or p-multipliers, are slightly conservative and compare well with the back-calculated p-y curves from this study. / Graduation date: 2012
Identifer | oai:union.ndltd.org:ORGSU/oai:ir.library.oregonstate.edu:1957/28476 |
Date | 12 March 2012 |
Creators | Barker, Paul D. (Paul David) |
Contributors | Ashford, Scott A. |
Source Sets | Oregon State University |
Language | en_US |
Detected Language | English |
Type | Thesis/Dissertation |
Page generated in 0.0017 seconds