Return to search

Prepara??o e caracteriza??o de sistemas de libera??o controlada de sinvastatina a partir de poli (3-hidroxibutirato)

Disponibiliza??o em conte?do parcial do trabalho, conforme Termo de Autoriza??o. / Submitted by Jos? Henrique Henrique (jose.neves@ufvjm.edu.br) on 2017-02-14T19:00:46Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
lays_fernanda_nunes_dourado_parcial.pdf: 389665 bytes, checksum: 2289d8ac4ca389d5cdaf516878ddae78 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2017-03-06T12:24:50Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
lays_fernanda_nunes_dourado_parcial.pdf: 389665 bytes, checksum: 2289d8ac4ca389d5cdaf516878ddae78 (MD5) / Made available in DSpace on 2017-03-06T12:24:50Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
lays_fernanda_nunes_dourado_parcial.pdf: 389665 bytes, checksum: 2289d8ac4ca389d5cdaf516878ddae78 (MD5)
Previous issue date: 2016 / Na ind?stria farmac?utica, os pol?meros s?o capazes de desempenhar a fun??o de matriz para libera??o controlada de f?rmacos. Isto tem como vantagem a minimiza??o dos efeitos adversos dos medicamentos e a otimiza??o do tratamento. Entre os pol?meros utilizados para tal finalidade, tem-se o poli(3-hidroxibutirato) (PHB) conhecido por sua origem natural, um material que se degrada a produtos n?o t?xicos para o organismo, o que garante o seu emprego como biomaterial. Quando utilizado em associa??o a outros pol?meros, s?o denominados Blendas, essas misturas modificam as caracter?sticas f?sico-qu?micas dos pol?meros para serem empregados em finalidades diversas. Desta forma este trabalho teve como objetivo o desenvolvimento de uma matriz polim?rica capaz de ser utilizada para libera??o controlada de f?rmacos. Para tal, foram produzidas duas membranas diferentes uma de PHB e outra de Blenda Poli (3-hidroxibutirato)/Polipropilenoglicol, PHB/PPG (90:10), com concentra??es diferentes de f?rmaco, contendo 5% e 25% em massa. O f?rmaco modelo foi a Sinvastatina. Estes dispositivos foram produzidos por dissolu??o seguida de evapora??o do solvente, formando filmes de 0,5 mm de di?metro que foram analisados quanto a sua degrada??o in vitro e in vivo, em implantes subcut?neos. Os materiais foram analisados utilizando espectroscopia na regi?o do infravermelho, termogravimetria, microscopia eletr?nica de varredura e por testes histol?gicos. Os filmes ? base de PHB, apresentaram degrada??o in vitro e in vivo mais lenta quando comparados ?s blendas, no entanto em ambos os casos, os materiais que continham maior percentual de Sinvastatina apresentaram maior degrada??o e libera??o do f?rmaco. As l?minas histol?gicas revelam a presen?a do tecido em torno dos dispositivos e aus?ncia de inflama??o o que comprova a biocompatibilidade dos materiais estudados. / Disserta??o (Mestrado) ? Programa de P?s-gradua??o em Ci?ncias Farmac?uticas, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2016. / In the pharmaceutical industry, the polymers are able to drive the controlled release of drugs. Its brings the advantage of minimizing adverse effects of medicines and optimization of treatment. Among the polymers used for this purpose the poly (3-hydroxybutyrate) has known for their natural origin, its degradation to non-toxic effects to the life tissue which ensures their use as subcutaneous implants. A blend is a mixture of different polymers, these mixtures are able to modify the physicochemical characteristics of the polymers for several uses. This study aimed to develop a polymer matrix can be used as a way for controlled release of drugs. For this purpose, two different membranes were produced, the PHB and a Poly(3-hydroxybutyrate)/Polypropylene glycol blends, PHB/PPG (90:10), with different concentrations of drug with 5% and another 25%. The simvastatin was chosen as a model. These devices were manufactured by casting to form films of 0.5 mm diameter that were analyzed for in vitro and in vivo degradation tests using subcutaneous implants. The materials were analyzed using infrared spectroscopy, thermogravimetric analysis, scanning electron microscopy and histological tests. The films based on PHB presented a slower degradation in vitro and in vivo degradation tests when compared to the blends, however in both cases those materials containing a higher percentage of simvastatin has shown the higher degradation and release of the drug. The histological sections showed a tissue colonization and absence of inflammation which demonstrates the biocompatibility of the implants.

Identiferoai:union.ndltd.org:IBICT/oai:acervo.ufvjm.edu.br/jspui:1/1184
Date15 July 2016
CreatorsDourado, Lays Fernanda Nunes
ContributorsRoa, Juan Pedro Bretas, Carvalho J?nior, ?lvaro Dutra de, Patr?cio, Patr?cia Santiago de Oliveira, Oliveira, Eduardo de Jesus, Carvalho J?nior, ?lvaro Dutra de, Universidade Federal dos Vales do Jequitinhonha e Mucuri (UFVJM), Roa, Juan Pedro Bretas
PublisherUFVJM
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFVJM, instname:Universidade Federal dos Vales do Jequitinhonha e Mucuri, instacron:UFVJM
RightsA concess?o da licen?a deste item refere-se ao ? termo de autoriza??o impresso assinado pelo autor, assim como na licen?a Creative Commons, com as seguintes condi??es: Na qualidade de titular dos direitos de autor da publica??o, autorizo a Universidade Federal dos Vales do Jequitinhonha e Mucuri e o IBICT a disponibilizar por meio de seus reposit?rios, sem ressarcimento dos direitos autorais, de acordo com a Lei n? 9610/98, o texto integral da obra disponibilizada, conforme permiss?es assinaladas, para fins de leitura, impress?o e/ou download, a t?tulo de divulga??o da produ??o cient?fica brasileira, e preserva??o, a partir desta data., info:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds