Return to search

Estudo experimental comparativo de implantes arteriais : politetrafluoretileno expandido (PTFE) versus polidimetilsiloxano com reforço de tecido de poliéster / Experimental comparative study of arterial implants - expanded polytetrafluoroethylene (PTFE) versus dimethylpolysiloxane reinforced with polyester fabric

INTRODUÇÃO: Os enxertos vasculares sintéticos disponíveis atualmente apresentam baixos índices de patência, quando utilizados na revascularização de vasos de pequeno calibre, e possuem resultados inferiores quando comparados ao uso de veias autólogas em derivações infrageniculares. Nova prótese de pequeno calibre confeccionada em silicone (polidimetilsiloxano, PDMS) com reforço de tecido de poliéster foi desenvolvida e comparada à prótese de PTFE. OBJETIVOS: Analisar, em modelo experimental em coelhos, o tubo de PDMS como material para prótese vascular e compará-lo a prótese de PTFE. MÉTODOS: Quarenta coelhos foram submetidos a interposição na aorta infrarrenal de próteses de 4mm de diâmetro, sendo 20 animais com PDMS e 20 com PTFE (grupo controle). Foi medido o tempo de clampeamento e realizada arteriografia retrógrada da aorta para avaliar a patência das próteses. Para avaliar a endotelização das próteses foi realizada microscopia eletrônica de maneira amostral pareada. RESULTADOS: Vinte e cinco animais (62,5%) não apresentaram intercorrências pós-operatórias; oito (20%) morreram precocemente e sete (17,5%) ficaram paraplégicos no pós-operatório imediato (e foram sacrificados), sendo que esses animais não foram incluídos nas análises de patência. Não foi observada diferença entre os grupos quanto à evolução com complicações pós-operatórias (p=0,526) e quanto ao tempo de clampeamento da aorta (p=0,299). A patência em 30 dias foi de 100% para as duas próteses. Aos 60 dias, a taxa de patência do PDMS foi de 92,3% (± 7,4), e de 73,8% (±13,1) em 90 dias; as próteses de PTFE tiveram taxas de patência de 87,5% (± 11,7) aos 60 e 90 dias. Não foi observada diferença significativa entre as taxas de patência dos grupos (p=0,62). Não houve diferença siginificativa entre os grupos quanto ao grau de estenose das próteses patentes (p=0,650) à avaliação angiográfica. A microscopia eletrônica mostrou crescimento endotelial limitado às regiões próximas às anastomoses nos dois tipos de próteses. CONCLUSÃO: O PDMS mostrou-se passível de utilização como prótese vascular, com resultados comparáveis aos do PTFE no modelo utilizado / INTRODUCTION: Synthetic vascular grafts currently available have suboptimal patency rates in small-diameter vessels and inferior outcomes in below-the-knee arterial bypass procedures when compared to the use of autologous vein. A new small vessel prosthesis made of silicone (polydimethylsiloxane, PDMS) and reinforced with polyester fabric was developed and compared to the standard PTFE prosthesis. OBJECTIVES: On a rabbit experimental model, we compared the outcomes of new PDMS vascular prostheses with PTFE vascular prostheses. METHODS: Forty rabbits underwent infra-renal aorta replacement with 4 mm diameter prostheses, twenty animals with PDMS and twenty animals with PTFE (control group). Aortic clamping time was measured and retrograde aortic angiography was performed to assess patency. Histological graft samples were examined by electron microscopy to evaluate prostheses endothelialization. RESULTS: Twenty-five (62,5%) animals had good surgical outcome; eight animals (20%) expired and seven animals (17.5%) became paraplegic (and subsequently sacrificed) during early follow up and were not included in anastomosis patency analysis. Postoperative complications (death, paraplegia) rates (p=0,526) and aortic clamping times (p=0,299) were comparable in both groups. Patency rates in 30 days were 100% for both grafts. At 60 days, patency rate for PDMS was 92,3% (±7,4), and 73,8% (±13,1) at 90 days. PTFE grafts had patency rates of 87,5% (±11,7) at 60 and 90 days. No statistically significant difference was found in between groups for patency rates (p=0,62). No statistically significant difference for stenosis was found on angiographical analysis in between groups (p=0,650). Electron microscopy revealed limited anastomotic endothelial ingrowth in both prostheses used. CONCLUSION: In this experimental model, PDMS and PTFE vascular prostheses had comparable outcomes and PDMS prosthesis could be used as a vacular graft

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-05082014-152556
Date30 May 2014
CreatorsFernanda Appolonio
ContributorsNelson de Luccia, Esdras Marques Lins, Marcelo Fernando Matielo, Erasmo Simao da Silva, Antonio Eduardo Zerati
PublisherUniversidade de São Paulo, Medicina (Clínica Cirúrgica), USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds