• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 58
  • 38
  • 9
  • 6
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 132
  • 21
  • 19
  • 18
  • 17
  • 14
  • 14
  • 14
  • 13
  • 11
  • 10
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Preparation, characterisation and properties of siloxane copolymers and dispersions / by Michael Shields.

Shields, Michael January 2003 (has links)
"October 2003" / Bibliography: leaves 184-187. / xiv, 192, [7] leaves : ill., photos ; 30 cm. / Title page, contents and abstract only. The complete thesis in print form is available from the University Library. / Thesis (Ph.D.)--University of Adelaide, School of Chemistry and Physics, Discipline of Chemistry, 2004
2

Preparation, characterisation and properties of siloxane copolymers and dispersions /

Shields, Michael January 2003 (has links) (PDF)
Thesis (Ph.D.) -- University of Adelaide, School of Chemistry and Physics, Discipline of Chemistry, 2004. / "October 2003" Bibliography: leaves 184-187.
3

Electron deficient polyarylenesiloxanes /

Braho, Dianne L. January 1996 (has links)
Thesis (M.S.)--Youngstown State University, 1996. / Includes bibliographical references (leaves 76-78).
4

The synthesis and chemistry of the products of addition to silicon-silicon double-bonded compounds

De Young, Douglas Jay. January 1984 (has links)
Thesis (Ph. D.)--University of Wisconsin--Madison, 1984. / Typescript. Vita. eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
5

Estudo dos ganglios linfaticos e reação tissular local em animais submetidos a implante subcutaneo de silicona gel, elastomero liso e texturizado

Hora, Evania Curvelo 30 March 2001 (has links)
Orientador : Cassio Menezes Raposo do Amaral / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-07-27T23:03:31Z (GMT). No. of bitstreams: 1 Hora_EvaniaCurvelo_M.pdf: 19504853 bytes, checksum: 4f1cbb13310e410abbabd3323a88a3fb (MD5) Previous issue date: 2001 / Resumo: As siliconas são biomateriais empregados na confecção de implantes utilizados em diversas especialidades médicas; são polímeros que se apresentam em três formas básicas: líquida, gel e elastômero e diferem entre si pelo comprimento e grau de reticulação das cadeias de polidimetilsiloxane. Seu uso é controverso, pois está relacionado a diversas reações orgânicas, dentre elas a linfadenopatia e formação de contratura capsular. O estudo foi realizado com a finalidade de se detectar alterações histológicas dos gânglios linfáticos axilares e inguinais sugestivas de reação aos implantes de silicona gel, elastômero liso e texturizado por meio da medida da área dos gânglios por morfometria computadorizada, e microscopia óptica comum e também comparar a reação tissular local aos mesmos implantes pela quantificação das fibras colágenas presentes na cápsula formada ao redor dos implantes. Para isso foram utilizados 63 ratos wistar divididos em quatro grupos: 15 para o gel, 15 para o elastômero liso, 15 para o texturizado, 15 para o grupo controle e 3 para o controle sanitário. As siliconas foram implantadas subcutaneamente no dorso e abdome dos animais e os periodos de observação foram 30, 90 e 180 dias. Foram adotados coloração HE para os gânglios linfáticos e Sirius Red para a cápsula. A análise estatística aplicada foi o modelo fatorial de análise de variância. Não se encontraram alterações histológicas nos gânglios linfáticos dos animais em estudo quando comparados ao grupo controle. Nem foram observadas diferenças estatisticamente significantes na análise quantitativa das fibras colágenas presentes nas cápsulas ao redor dos implantes de gel, elastômero liso e texturizado. Diferenças estatisticamente significantes na quantidade de fibras colágenas com relação ao período de observação foram notadas, apresentando-se de forma decrescente em 30, 90 e 180 dias; e quanto à localização, mostraram-se maiores no dorso do que no abdome, porém essa diferença estreitou-se ao longo do período de observação, permanecendo insignificante no período de 180 dias. Tais conclusões contradizem alguns estudos clínicos e confirmam outros, demonstrando a natureza controversa do assunto e estimulando novas pesquisas em busca de um consenso mundial sobre o emprego dos compostos de silicona / Abstract: Silicones are a biomaterial used in the production of implants and applied in several medical fields; it consists of polymers presenting three basic types: liquid, gel and elastomers which differ among themselves in length and degree of polydymethilsiloxane chain reticulation. Its use is controversial since it is related to several organic reactions such as lymphadenopathy and formation of capsular contracture. The objective of this study is to detect histological alterations of the lymphatic axillary and inguinal ganglions suggestive of reaction to gel silicon implants, smooth and texturized elastomers, measuring the ganglions area through a computerized morphometry and common optical microscopy and also to compare local tissular reaction to the same implants by collagen fiber quantification present in the capsule formed around the implants. Sixty-three wistar rats were used and divided into four groups: 15 for gel, 15 for smooth elastomers, 15 for texturized, 15 for control group and 3 for sanitary controI. Silicones were subcutaneously implanted into the dorsum and abdomen of the animaIs and the observation periods were 30, 90 and 180 days. HE coloration was used for the lymphatic ganglions and Sirius Red for the capsule. Statistical analysis applied was the factorial model of the variance analysis. No histological alterations in the lymphatic ganglions of the studied animaIs were found when comparing to that of the control group. AIso, no statistical significant differences were observed in the quantitative analysis of the collagen fibers in the capsules around the gel implant, smooth and texturized elastomers. Statistically significant differences regarding number of collagenous fibers in relation to the observation period were observed and presented in a decreased order of 30, 90 and 180 days; regarding localization, those in the dorsum were greater than those in the abdomen, but this difference was reduced in the observation period and not being significant in the period of 180 days. These conc1usions are not in accordance with some c1inical studies and, though, they are in agreement with others, showing the controversial nature of this subject, favoring new researches aiming the international consensus on the use of silicone compounds / Mestrado / Mestre em Cirurgia Medica
6

Complicações abdominais do cateter distal no tratamento da hidrocefalia com migração, perfuração e/ou extrusão : uma hipotese inflamatoria

Aquino, Humberto Belem de 13 July 2004 (has links)
Orientador: Edmur Franco Carelli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-04T01:09:06Z (GMT). No. of bitstreams: 1 Aquino_HumbertoBelemde_M.pdf: 4567742 bytes, checksum: 52332c2843c17c9e3a50d8797393b838 (MD5) Previous issue date: 2004 / Resumo: A hidrocefalia é uma desordem bem documentada na literatura neurocirúrgica, cujo tratamento, ainda se faz através do desvio do líquido cefalorraquidiano (LCR) para um local extracerebral, através de um sistema de tubos de silicone. A cavidade peritoneal é o local mais usado em todo o mundo, para a absorção do LCR, que se acumula dentro do sistema ventricular, que apesar de não ser a forma ideal, ajuda a melhorar o prognóstico. Muitas complicações desta forma de tratamento são bem descritas na literatura, no entanto, as complicações abdominais decorrentes da migração com perfuração e/ou extrusão do cateter distal não são adequadamente estudadas, motivo este do não entendimento destas complicações. Excluindo as complicações mecânicas ou funcionais, e as complicações infecciosas, as complicações abdominais relacionadas com a migração, perfuração e/ou extrusão do cateter distal, junto com a mal absorção do LCR dentro da cavidade peritoneal e a formação do pseudocisto cisto peritoneal podem ser agrupadas, e assim chamadas de ¿Complicações abdominais não-funcionais do cateter distal¿ do tratamento da hidrocefalia, onde uma característica importante entre estas complicações, é a permanência do sistema de derivação ventrículo-peritoneal funcionando. Não está claro, no entanto, de como estas complicações ocorrem, e para isto, este estudo se preocupou em avaliar o relacionamento entre o material de silicone dos sistemas de derivação ventricular usados pra desviar o LCR, os elementos do LCR, principalmente a glicose, proteína e leucócitos, assim como a forte reatividade da cavidade peritoneal. Para a busca de informações que apóiam uma ¿hipótese inflamatória crônica¿ como responsável por desencadear as complicações abdominais, quatro etapas foram desenvolvidas como método para a obtenção dos objetivos, como: a avaliação do número de casos submetidos a DVP no Hospital Municipal Dr.José de Carvalho Florence, de São José dos Campos, São Paulo, Brasil, e do número de complicações abdominais não-funcionais relacionadas com a migração, perfuração e/ou extrusão, a meta-análise da literatura mundial referentes as complicações observadas, e estudadas entre os anos de 1966-2003, da aplicação de um protocolo em cada trabalho estudado na meta-análise, e pelo estudo histológico do peritônio de dois casos (ascite liquórica e pseudocisto peritoneal), e da parede do pseudocisto, que reforçaram a hipótese sugerida no estudo / Abstract: Hidrocephalus is a well documented disorder at the neurosurgery literature and it is still made through the shunt of the cerebrospinal fluid (CSF) to a cerebrodistal local (site), through a silicon tube system. The peritoneal cavity is the most used site, all over the world, in order to do the CSF absorption, which accumulates into the ventricular system, although it is not considered as being the best way of doing so, it helps improving the prognosis. Many complications regarding to this type of treatment are well described in the literature, although the abdominal complications due to the migration with perforation and/or the extrusion of the distal catheter are not well studied, which shows the non-understanding of these complications. Excluding the functional, mechanic and infectious complications besides the abdominal ones related to the migration, perforation and/or extrusion of the distal catheter, together with the poor CSF absorption inside the peritoneal cavity and the constitution of the peritoneal cyst pseudocyst could be grouped together and they can be called ¿non ¿functional abdominal complications of the distal catheter¿ at the hydrocephalus treatment, where an important feature among these complications, is the permanence of the ventriculoperitoneal shunt system still working. It is not clarified, therefore, how these complications occur, and due to it, this study was concerned about assessing the relationship among the silicon material of the ventricular shunt systems used to shift the CSF, the CSF elements (components), specially the glucose, protein and leukocytus as well as a strong reactivity of the peritoneal cavity. In order to search the information which supports ¿the chronic inflammatory hypothesis¿ as being responsable by triggering the abdominal complications, four (4) stages were developed as a method in order to obtain the following aims: the assessment of the number of cases undergone to VPS (Ventriculoperitoneal shunt system) at a town hospital ¿Dr. José de Carvalho Florence¿ in São José dos Campos, São Paulo, Brazil and the number of non-functional abdominal complications related to migration, perforation and/or extrusion, the meta-analysis of the worldwide literature regarding to the observed complications, and that were studied between the years of 1966-2003, and the use of a protocol in each studied work of the meta-analysis, and by the histologic study of the peritoneus of two (2) cases (liquor ascitis and peritoneal pseudocyst) and from the pseudocyst wall, which reinforce the suggested hypothesis in this study / Mestrado / Neurologia / Mestre em Ciências Médicas
7

The effect of silicones on the light fastness of acid dyes applied to nylon

Abrams, Walter Gilbert January 1955 (has links)
No description available.
8

The effect of silicone water repellent finishes on the crocking properties of dyed fabrics

Gordon, Ivan Herbert January 1956 (has links)
No description available.
9

Investigation of methods for removal of silicones from nylon and acetate fabrics

Bresnahan, Joseph Estill 12 1900 (has links)
No description available.
10

The development and characterisation of new silicon materials /

Folland, Peter David Unknown Date (has links)
Thesis (MAppSc)--University of South Australia, 1997

Page generated in 0.0312 seconds