Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:53:51Z (GMT). No. of bitstreams: 1
Damaceno_AlessandraReginaDerogis_M.pdf: 1414206 bytes, checksum: c7d213655bfe8d988e6311566b91787d (MD5)
Previous issue date: 2005 / Resumo: Este estudo avaliou comparativamente duas técnicas indicadas para a obtenção de melhor assentamento de próteses implanto-suportadas através da análise fotoelástica. Para isso, foram obtidos dois grupos de infra-estruturas metálicas em titânio construídas sobre uma matriz metálica com forma e dimensões similares ao arco mandibular, sendo: Grupo 1- três infra-estruturas confeccionadas pela técnica da soldagem de borda a laser de cilindros pré-fabricados; Grupo 2- três infra-estruturas fundidas em monobloco e submetidas ao sistema de retificação de cilindros fundidos. Após avaliação em microscopia óptica, apenas a infra-estrutura mais bem adaptada de cada grupo foi submetida à análise fotoelástica variando-se três seqüências de aperto dos parafusos (1/2/3/4/5, 5/4/3/2/1 e 3/2/4/1/5). De maneira adicional, a infra-estrutura representante do grupo 2 foi submetida, após a primeira análise, à secção e soldagem vertical das partes, e reavaliada. Os resultados mostraram formação de maior quantidade de tensões nas seqüências de aperto 1/2/3/4/5 e 5/4/3/2/1, para ambos os grupos analisados. A estrutura submetida à soldagem de borda de cilindros pré-fabricados mostrou melhores resultados, apesar de a mesma apresentar maiores valores de desadaptação (165µm) quando comparada àquela que teve seus cilindros submetidos à retificação de borda antes (54µm) ou após a secção e soldagem vertical (117µm). A seqüência de aperto 3/2/4/1/5 mostrou melhores resultados. Portanto, o grupo dos cilindros submetidos à soldagem de borda induziu melhores resultados principalmente quando associada à seqüência de aperto 3/2/4/1/5 / Abstract: This study evaluated two techniques indicated to obtain implant-supported fixed prostheses with satisfactory passive fit by means of photoelastic analysis. Two titanium casts groups were fabricated in a metallic master cast: Group I ¿ three frameworks fabricated by laser welded cylinder technique and Group II ¿ three frameworks cast in one-piece and submitted to Rectification Cylinder System. After optical microscopy evaluation, only the better-fit framework of both groups was submitted to the photoelastic analysis, testing three screw tightening sequences (5/4/3/2/1; 1/2/3/4/5 and 3/2/4/1/5). Subsequent to the first analysis, the selective framework of Group II was sectioned and laser welded to be submitted to a new evaluation. Results showed superior stress magnitude in 1/2/3/4/5 and 5/4/3/2/1 sequences of both groups, while 3/2/4/1/5 screw tightening sequence presented better stress results of them. Laser welded cylinder framework illustrated better results, even though had showed superior values of misfit (165µm) compared to the rectified framework before (54µm) and after section and vertical laser welded (117µm). Laser welded cylinder group achieved better results mainly allied to 3/2/4/1/5 screw tightening sequence / Mestrado / Protese Dental / Mestre em Clínica Odontológica
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288277 |
Date | 02 March 2005 |
Creators | Damaceno, Alessandra Regina Derogis |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Nóbilo, Mauro Antonio de Arruda, 1965-, Lagana, Dalva Cruz, Henriques, Guilherme Elias Pessanha |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 112p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0115 seconds