Análise teórico-experimental das forças verticais e de atrito em silos cilíndricos. / Theoretical-experimental analysis of the vertical and frictional forces in cylindrical silos.

Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-07-12T17:08:09Z
No. of bitstreams: 1
JOSÉ PINHEIRO LOPES NETO - TESE PPGEP 2009..pdf: 23810467 bytes, checksum: e50a917ae6d8753266701669df9c50a1 (MD5) / Made available in DSpace on 2018-07-12T17:08:09Z (GMT). No. of bitstreams: 1
JOSÉ PINHEIRO LOPES NETO - TESE PPGEP 2009..pdf: 23810467 bytes, checksum: e50a917ae6d8753266701669df9c50a1 (MD5)
Previous issue date: 2009-10 / Para que um projeto econômico e seguro de silos verticais seja desenvolvido, é necessário que fatores como fluxo e cargas sejam criteriosamente avaliados. Portanto, como objetivo principal desta pesquisa destaca-se a mensuração e análise das forças de atrito nas paredes de um silo cilíndrico de fundo plano. Para a medição das forças de atrito foram utilizados dois conjuntos de três células de carga e um sistema de aquisição de dados. O silo foi carregado concêntrica e excentricamente com areia seca para duas diferentes relações HJDC (0,8 e 1,6) e descarregado concentricamente e a partir
de seis excentricidades através de orifícios de 80 mm de diâmetro. Os resultados evidenciam que o modelo de silo-piloto é adequado para a medição das forças de atrito nas paredes e que a sua distribuição é mais regular quando descarregado através das descargas combinadas 50-50% e 7575%. Entretanto, estas descargas produziram elevados valores de força de atrito nas paredes. / For economic e safe design of vertical silos, factors such as flow and loads conditions must be carefully analyzed. The aim of this research were to measure and analyze the friction forces in cylindrical silo wall with flat bottom. For friction load measurement two set of three load cells and a data logger were used. The silo was centric and eccentric filled with dry sand to two different Ho/Dc rations (0,8 e 1,6) and was unloaded either centrically or at six different eccentric locations through circular orifices with a diameter of 80 mm. The results showed mat the model of the cylindrical silo can be used to evaluate the friction forces in silo walls and a regular friction load distribution occurred when the silo was emptied either 50-50% or 75-75% discharge conditions. However, these
discharge conditions produced high values of friction force in silo walls.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:riufcg/1164
Date12 July 2018
CreatorsLOPES NETO, José Pinheiro.
ContributorsNASCIMENTO, José Wallace Barbosa do., CALIL JÚNIOR, Carlito., CHAGAS FILHO, Milton Bezerra das., GOMES, Josivanda Palmeira., MINÁ, Alexandre Soares.
PublisherUniversidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM ENGENHARIA DE PROCESSOS, UFCG, Brasil, Centro de Ciências e Tecnologia - CCT
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG