Desempenho biomecânico de sistemas de barra para retenção adicional de sobredentaduras : análise de elementos finitos / Biomechanical performance of overdenture-retaining bar system: finite element analysis

Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T04:13:28Z (GMT). No. of bitstreams: 1
Spazzin_AloisioOro_D.pdf: 2599609 bytes, checksum: 3bc29d307ef5b6eeccc41da825aaec01 (MD5)
Previous issue date: 2013 / Resumo: Neste estudo foram avaliados os efeitos da amplificação do desajuste horizontal, material e formato da secção transversal da barra, e da reabsorção óssea peri-implantar na distribuição das tensões estáticas em um sistema de barra para retenção adicional de sobredentaduras utilizando o método dos elementos finitos. Para a análise computacional, foi criado um modelo tridimensional incluindo dois implantes de titânio e uma barra metálica colocada na região anterior de uma mandíbula severamente reabsorvida. Quatro diferentes ligas (ouro, prata-paládio, cobalto-cromo e titânio comercialmente puro) e três diferentes formatos da secção transversal (circular, ovoide e Hader) da barra foram avaliados. Uma região anterior de mandíbula simulando uma reabsorção óssea peri-implantar de 1,4 mm de altura foi também criada. Os modelos foram exportados para programas de simulação mecânica, em que deslocamentos foram aplicados simulando distorção da barra que sofreu contração durante os procedimentos laboratoriais. Quatro análises foram realizadas, separadamente, para reduzir a quantidade de modelos envolvidos: Capítulo 1 - i) diferentes desajustes horizontais (10, 50, 100, e 200 ?m) utilizando liga de ouro como material da barra; ii) diferentes materiais da barra simulando 50 ?m de desajuste horizontal (neste capítulo foi utilizada barra de secção transversal circular); Capítulo 2 - iii) diferentes secções transversais da barra simulando diferentes desajustes horizontais (10, 50 e 100 ?m); iv) diferentes secções transversais da barra simulando 1,4 mm de reabsorção óssea peri-implantar e 50 ?m de desajuste horizontal (neste capítulo foi utilizado liga de cobalto-cromo como material da barra). Os dados foram analisados por meio de figuras e dados numéricos gerados pelos programas. A amplificação do desajuste horizontal aumentou os níveis de tensões estáticas nas estruturas do sistema. Materiais mais rígidos e geometrias mais complexas da barra aumentaram os níveis de tensões estáticas no sistema de barra quando desajustes horizontais estão presentes. A reabsorção óssea simulada aumentou a deformação e a concentração de tensões no tecido ósseo peri-implantar quando desajustes horizontais estão presentes / Abstract: In this study were evaluated the effects of horizontal misfit amplification, material and cross-section geometry of the bar, and peri-implant bone loss on the distribution of static stresses in an overdenture-retaining bar system using finite element analysis. For the computational analysis, a three-dimensional model was created including two titanium implants and a metallic bar placed in the anterior part of a severely resorbed jaw. Four different alloys (gold, silver-palladium, cobalt-chromium, and commercially pure titanium) and three different cross-section geometries (circular, ovoid and Hader) of the bar were evaluated. An anterior part of jaw simulating a peri-implant bone loss of 1.4 mm height was also created. The models were exported to mechanical simulation software, where horizontal displacements were applied simulating the settling of the bar that suffered shrinkage during laboratory procedures. Four analyses were carried out, separately, to reduce the quantity of involved models: Chapter 1 - (i) different horizontal misfits (10, 50, 100, and 200 ?m) using gold alloy as bar material; (ii) different bar materials simulating 50-?m misfit horizontal (circular cross-section of the bar was used in this chapter); Chapter 2 - (iii) different cross-section geometries of the bar simulating different horizontal misfits (10, 50 and 100 ?m); (iv) different cross-section geometries of the bar simulating 1.4-mm peri-implant bone loss and 50-?m horizontal misfit (cobalt-chromium alloy was used as bar material in this chapter). Data were analyzed using figures and numerical data generated by software. The amplification of the horizontal misfit increased the levels of static stress in the structures of the system. Stiffer materials and more complex geometries of the bar increased the levels of static stress on bar system when horizontal misfits are present. The bone loss simulated increased the strain and stress concentration in the peri-implant bone tissue / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289563
Date02 May 2013
CreatorsSpazzin, Aloísio Oro, 1984-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Correr Sobrinho, Lourenço, 1960-, Moraes, Rafael Ratto, Brandt, Willian Cunha, Lopes, Murilo Baena, Consani, Simonides
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Materiais Dentários
Source SetsIBICT Brazilian ETDs
LanguageInglês
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format62 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds