Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T19:07:40Z (GMT). No. of bitstreams: 1
Barberi_JulianaTamiao_M.pdf: 6032748 bytes, checksum: 3f9207c911e4693fec735f279de88fa3 (MD5)
Previous issue date: 2007 / Resumo: O presente estudo avaliou o assentamento passivo em infra-estruturas de próteses fixas implanto-suportadas, através de análise fotoelástica da distribuição de tensões em virtude do grau de desadaptação. A partir de uma matriz metálica no formato e dimensões similares a um arco mandibular, contendo cinco análogos de pilares Micro-Unit (Conexão ¿ São Paulo), foram confeccionadas duas estruturas metálicas fundidas em titânio comercialmente puro (Tritan® ¿ Dentaurum ¿ Alemanha), obtidas pelas seguintes técnicas: Estrutura I, cilindros cimentados com ionômero de vidro modificado por resina (RelyX® Luting 2 ¿ 3M ESPE); e Estrutura II, cilindros soldados a laser e subsequente refinamento por eletroerosão (EDM). A partir de um molde de silicone de duplicação foi confeccionado um modelo em resina fotoelástica (Araldite® GY279BR Huntsman ¿ Araltec Produtos Químicos Ltda. ¿ Guarulhos ¿ São Paulo) com cinco implantes incorporados e pilares Micro-Unit. As estruturas foram então submetidas à análise fotoelástica conduzida pelo aperto dos parafusos na seqüência preconizada 3,2,4,1,5. Seqüencialmente, mensurações foram realizadas na interface estrutura/pilar intermediário com auxílio de um microscópio mensurador, com precisão de 0,0005mm (STM Digital ¿ Olympus ¿ Japão) através do teste do parafuso único. A estrutura dos cilindros cimentados apresentou os melhores resultados com menor valor de desadaptação (42,37 mm) e maior distribuição das tensões, quando comparada à estrutura dos cilindros soldados a laser (83,66 mm), a qual após o procedimento de EDM e subseqüente análise fotoelástica demonstrou redução no grau de desadaptação (53,7 mm) e melhor distribuição de tensão. Pode-se concluir que o processo de cimentação dos cilindros à estrutura optimiza a adaptação marginal desta e minimiza os padrões de tensões, sendo eficaz para a obtenção do assentamento passivo / Abstract: The purpose of the study was to evaluate the passive fit of fixed implantsupported prothesis titanium frameworks, through photoelastic stress analysis. Two frameworks welded in commercially pure titanium (Tritan® ¿ Dentaurum ¿ Germany) were fabricated by two methods based on a metal model composed of five analogous Micro-Unit (Conexão ¿ São Paulo): Framework I, abutment-luted with resin-modified glass ionomer luting cement (RelyX® Luting 2 ¿ 3M ESPE); and framework II, cylinders laser-welding technique and was then refined using electric discharge machining. Photoelastic model was obtained (Araldite® GY279BR Huntsman ¿ Araltec Produtos Químicos Ltda. ¿ Garulhos ¿ São Paulo) with five fixtures and abutments Micro-Unit. Strains were produced around the implant bodies when screws retaining the prosthesis were tightened sequence 3,2,4,1,5, and strains were evaluated by photoelastic analysis. The interfacial gaps between the abutments and fixture were measuremented with an optical microscope (STM Digital ¿ Olympus ¿ Japan) 0,0005mm of precision. The interfacial gaps were smaller in the abutment-luted framework (42,37 mm), demonstrated the lower stress when compared to the laser-welded cylinder framework (83,66 mm). The electric discharge machining (EDM) reduced the gaps at the interfaces (53,7 mm) and the strains for framework welded. It may be concluded that the process of abutment-luted realized in frameworks improves the precise fit of it, can be recommended of achieving precise fit of implant-supported prothesis / Mestrado / Protese Dental / Mestre em Clínica Odontológica
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288269 |
Date | 30 May 2007 |
Creators | Barberi, Juliana Tamião |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Nóbilo, Mauro Antonio de Arruda, 1965-, Ribeiro, Ricardo Faria, Mesquita, Marcelo Ferraz |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 90p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0025 seconds