Return to search

Avaliação clínica e radiográfica dos tecidos peri-implantares de implantes osseointegrados que receberam carregamento imediato

Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0
Previous issue date: 2004-02-27Bitstream added on 2014-06-13T19:15:55Z : No. of bitstreams: 1
lemo_vs_me_arafo.pdf: 419894 bytes, checksum: cba02ae2b99c2cf288790005f4e2b328 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Um estudo clínico e radiográfico foi realizado para analisar o resultado do tratamento com implantes unitários e unidos (prótese protocolo), instalados e imediatamente carregados. O estudo inclui 10 pacientes que receberam 10 implantes e próteses provisórias unitárias e 5 pacientes que receberam 25 implantes, 5 implantes cada paciente entre os foramens mentoniano, estes foram unidos e receberam uma prótese tipo protocolo. Todas as próteses foram instaladas imediatamente após a cirurgia. Em um intervalo de 6 e 12 meses todos os pacientes foram radiografados e avaliados clinicamente. Não foram registradas perdas no grupo de implantes unitários e o grupo de implantes que recebeu prótese protocolo perdeu 2 implantes. Não houve alterações nos parâmetros periodontais (clínicos e radiográficos) entre os períodos de 6 e 12 meses, e as diferenças encontradas entre os implantes unitários e unidos, parecem estar mais relacionados ao local de inserção (maxila - mandíbula). Podemos concluir que a carga imediata é um procedimento previsível tanto para implantes unitários como em implantes unidos. / The study includes 10 patient that received 10 implants and unitary temporary prostheses and 5 patient that received 25 implants, 5 implants each patient one in the area previous of jawbone, these were united and they received a prosthesis type protocol. All of the prostheses were installed immediately after the surgery. In an interval of 6 and 12 months all the patients were x-rayed and evaluated clinically. Losses were not registered in the group of unitary implants and the group of implants that it received prosthesis protocol lost 2 implants. There were not alterations in the periodontal parameters (clinical and radiographic) among the periods of 6 and 12 months, and the differences found among the unitary and united implants, they seem to be more related to the insert place (jawbone - jaw). We can conclude that the immediate load is a previsible procedure so much for unitary implants as in united implants.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/96199
Date27 February 2004
CreatorsLemo, Vagner Samy [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Marcantonio, Elcio [UNESP], Marcantonio Junior, Elcio [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format109 f. : il.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1, -1

Page generated in 0.0144 seconds