Return to search

Verificação da presença e abertura dos túbulos dentinários em pacientes portadores de recessão gengival com e sem hipersensibilidade dentinária por microscopia eletrônica de varredura

Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-13T11:30:14Z
No. of bitstreams: 1
isabeladefilipovieira.pdf: 8371315 bytes, checksum: b4b3254d5ed0348cbbbb19599448153f (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T11:51:38Z (GMT) No. of bitstreams: 1
isabeladefilipovieira.pdf: 8371315 bytes, checksum: b4b3254d5ed0348cbbbb19599448153f (MD5) / Made available in DSpace on 2016-07-13T11:51:38Z (GMT). No. of bitstreams: 1
isabeladefilipovieira.pdf: 8371315 bytes, checksum: b4b3254d5ed0348cbbbb19599448153f (MD5)
Previous issue date: 2011-06-20 / O objetivo deste estudo foi verificar a presença e abertura dos túbulos
dentinários em pacientes portadores de recessão gengival com e sem
hipersensibilidade dentinária por microscopia eletrônica de varredura. Foram
selecionados 11 pacientes onde foram avaliados os dentes sensíveis e não
sensíveis, sendo constituídos dois grupos (n = 11), onde GE – experimental, onde
foram considerados os dentes com hipersensibilidade e GC – controle, os dentes
não sensíveis. Para a seleção dos dentes do GE, utilizou-se jato de ar por 3
segundos, sendo escolhido aquele em que o paciente relatou maior dor e para o GC
utilizou-se o mesmo procedimento, sendo selecionado, aleatoriamente, um dos
dentes em que o paciente não relatou dor. No exame periodontal foi mensurado o
nível clínico de inserção no sítio vestibular, sendo o exame realizado por um único
examinador devidamente calibrado. A partir das moldagens com silicona de adição
foram obtidas réplicas negativas para análise em microscópio eletrônico de
varredura para verificação da presença e características dos túbulos dentinários
frente aos GE e GC. A medida de 2 mm do nível clínico de inserção foi prevalente
com 63,60% (n = 7) para o GC, seguida de 3 mm com 45,50% (n = 5) para o GE. O
nível clínico de inserção dos dentes do GC atingiu uma média de 2,45 ± 0,69 mm e
do GE, 3,18 ± 1,16 mm. Quanto à presença e características ultramicroscópicas dos
túbulos dentinários, a Prova dos Sinais demonstrou que a média de abertura dos
túbulos dentinários do GE foi maior que do GC, 57,72 Rm e 34,82 Rm,
respectivamente. Quanto ao número de túbulos dentinários, a situação se repetiu,
porém com uma média de 1,45 para o GC e 3,18 para o GE (p = 0,044). Portanto,
com base nos resultados obtidos neste estudo, foi possível concluir que pacientes
portadores de recessão gengival com hipersensibilidade dentinária cervical
apresentam túbulos dentinários em maior número e abertos ou semiabertos com
diferentes diâmetros e que a técnica da réplica negativa analisada por microscopia
eletrônica de varredura demonstrou ser uma importante ferramenta para
visualização de túbulos dentinários. / The aim of this study was to determine the presence and opening of
dentinal tubules, by scanning electron microscopy, in teeth of patients with gingival
recession with and without dentin hypersensitivity. Eleven patients were selected,
and sensitive and non-sensitive teeth were evaluated and divided into two groups (n
= 11), where GE – experimental, which were considered hypersensitive teeth and GC
– control, non-sensitive teeth. For the selection of the teeth of GE, air blast was used
for 3 seconds, and was chose the one which the patient reported increased pain and
the GC used the same procedure, selecting randomly, a tooth where the patient
reported no pain. Periodontal examination measured the clinical attachment level at
buccal side, and the examination was performed by a single examiner calibrated.
From the impressions with vinyl polysiloxane, negative replica was obtained for
analysis in scanning electron microscope to detect the presence and characteristics
of dentinal tubules compared to the GE and GC. The measurement of 2 mm of
clinical attachment level was prevalent in 63.60% (n = 7) for the GC, followed by 3
mm with 45.50% (n = 5) for GE. The clinical attachment level of the teeth of GC
averaged 2.45 ± 0.69 mm and GE, 3.18 ± 1.16 mm. Regarding the presence and
ultramicroscopic characteristics of dentinal tubules, the Statistical Test Signals
showed that the average opening of dentinal tubules of GE was higher than the GC,
57.72 3m and 34.82 3m, respectively. Regarding the number of dentinal tubules, the
situation was repeated, but with an average of 1.45 for GC and 3.18 for GE (p =
0.044). Therefore, based on the results of this study, it can be concluded that
patients with gingival recession and dentin hypersensitivity present dentinal tubules
in greater numbers and open or half-open with different diameters and that the
technique of negative replica analyzed by scanning electron microscopy is an
important tool for visualization of dentinal tubules.

Identiferoai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/1760
Date20 June 2011
CreatorsVieira, Isabela Defilipo
ContributorsCarmo, Antônio Márcio Resende do, Chaves, Maria das Graças Afonso Miranda, Falabella, Márcio Eduardo Vieira, Rodrigues, José Roberto, Huhtala, Maria Filomena Rocha Lima
PublisherUniversidade Federal de Juiz de Fora, Programa de Pós-graduação em Clínica Odontológica, UFJF, Brasil, Faculdade de Odontologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds