Submitted by JAIMIS SAJID LEON COLQUI null (jeimis.leon@gmail.com) on 2017-06-30T12:04:16Z
No. of bitstreams: 1
Dissertação_Jaimis Leon_Eng_Eletrica.pdf: 1870541 bytes, checksum: cb3fb21a21d28fea6773b5e6d6b213bd (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-06-30T14:27:39Z (GMT) No. of bitstreams: 1
leoncolqui_js_me_ilha.pdf: 1870541 bytes, checksum: cb3fb21a21d28fea6773b5e6d6b213bd (MD5) / Made available in DSpace on 2017-06-30T14:27:39Z (GMT). No. of bitstreams: 1
leoncolqui_js_me_ilha.pdf: 1870541 bytes, checksum: cb3fb21a21d28fea6773b5e6d6b213bd (MD5)
Previous issue date: 2017-01-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta uma proposta de estratégia global de controle de tensão que emprega programação não linear e duas extensões de estratégias de controle de tensão, encontrados na literatura. O principal objetivo destas estratégias é solucionar o problema de aumento de tensão nas redes de distribuição de baixa tensão, causado pela injeção de potência do gerador fotovoltaico distribuído. Estas estratégias de controle de tensão foram implementadas e analisadas a fim de verificar a sua eficácia e comparar os seus comportamentos. Para os testes, foram considerados a operação de geradores fotovoltaicos monofásicos e trifásicos distribuídos em um sistema teste de distribuição em baixa tensão. Os resultados mostraram que depois da aplicação das estratégias de controle, os perfis de tensão em regime permanente ficaram dentro da faixa de tensão permitida, obtendo-se uma mínima redução de potência ativa injetada dos geradores fotovoltaicos com os seus correspondentes fatores de potência. / This work presents a proposal of a global voltage control strategy that use nonlinear programming and two extensions of voltage control strategies that are found in the literature. The main objective of these strategies is to solve the problem of voltage increase in low voltage distribution networks, caused by the power injection of the distributed photovoltaic generator. These voltage control strategies have been implemented and analyzed in order to verify their effectiveness and compare their behaviors. For the test, the operation of single-phase and three-phase photovoltaic generators distributed in a low voltage distribution test system were considered. The results showed that after the application of the control strategies, the steady-state voltage profiles were whihin the allowed voltage range, obtaining a minimum reduction of the active power injection of the photovoltaic generators with their corresponding powe factors.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/151020 |
Date | 30 January 2017 |
Creators | Leon Colqui, Jaimis Sajid [UNESP] |
Contributors | Universidade Estadual Paulista (UNESP), Feltrin, Antonio Padilha [UNESP] |
Publisher | Universidade Estadual Paulista (UNESP) |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP |
Rights | info:eu-repo/semantics/openAccess |
Relation | 600 |
Page generated in 0.0027 seconds