It is well known that arching action in reinforced concrete slabs resulting from surrounding restraining elements is responsible for much greater collapse loads than those estimated considering flexural effects only. However, the subject needs to be better understood and simplified if it is to be reliably applied in broader practice. This thesis presents a rational treatment of the problem. By limiting the scope of investigation to one-way slab systems, for the first time an explicit method of calculating the load-carrying capacity of elastic- plastic slab strips with a laterally rigidly restrained boundary condition is derived. Application of the proposed model to specimens selected from four experiment programs proves its reliability in ultimate strength calculations. The proposed model is then employed in a parametric study of structural responses of deck slab strips. The parametric study shows that a longer span, lightly reinforced deck slab system is still adequate in strength if it is cast in higher strength concrete and sufficient lateral restraint is available.
Identifer | oai:union.ndltd.org:TORONTO/oai:tspace.library.utoronto.ca:1807/35148 |
Date | 19 March 2013 |
Creators | Wu, Sixian |
Contributors | Gauvreau, Douglas Paul |
Source Sets | University of Toronto |
Language | en_ca |
Detected Language | English |
Type | Thesis |
Page generated in 0.0027 seconds