Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-09-18T18:29:01Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoPsicofisicaVisao.pdf: 8135129 bytes, checksum: 13f5f614ea3e9e85901f3f1c54f91ff8 (MD5) / Rejected by Irvana Coutinho (irvana@ufpa.br), reason: Aguardar as orientações on 2017-10-10T16:48:48Z (GMT) / Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-17T17:38:30Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoPsicofisicaVisao.pdf: 8135129 bytes, checksum: 13f5f614ea3e9e85901f3f1c54f91ff8 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-11-22T18:20:04Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoPsicofisicaVisao.pdf: 8135129 bytes, checksum: 13f5f614ea3e9e85901f3f1c54f91ff8 (MD5) / Made available in DSpace on 2017-11-22T18:20:04Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AvaliacaoPsicofisicaVisao.pdf: 8135129 bytes, checksum: 13f5f614ea3e9e85901f3f1c54f91ff8 (MD5)
Previous issue date: 2017-07-01 / Os aneurismas intracranianos saculares constituem a principal causa de hemorragia meníngea
ou subaracnóidea espontânea. As complicações derivadas do surgimento de aneurismas
saculares e de hemorragia meníngea, classificadas como sensoriais (acuidade e campo visual),
motoras (motilidade do músculo extraocular), e perceptuais, são consideradas como bem
estudadas na neurocirurgia devido à relativa semelhança entre casos. Entretanto, pouco se
sabe sobre possíveis alterações perceptuais e cognitivas pós-operatórias. No presente estudo
foi avaliada a sensibilidade visual de pacientes em condição pós-operatória de aneurisma
intracraniano do sistema carotídeo a estímulos espaciais acromáticos e cromáticos. A
sensibilidade ao contraste espacial de luminância foi medida em 11 freqüências espaciais (0.2,
0.5, 0.8, 1, 2, 4, 8, 10, 15, 20, e 30 ciclos/grau). A capacidade de discriminação de cores foi
medida por uma versão do teste de Farnsworth-Munsell com 85 matizes, divididas em quatro
séries apresentadas seqüencialmente, sendo uma com 22 estímulos e três com 24 estímulos.
Para a medida dos limiares de discriminação de cores, foram determinadas 5 elipses de
discriminação de cores de MacAdam e, para cada uma delas, foram medidos os limiares de
discriminação de cores em 20 direções no espaço de cor CIE 1976, através do teste de
Mollon-Reffin. As variáveis estudadas foram comparadas às normas estatísticas de controle,
pareadas em idade. Os resultados mostram que, em geral, não houve perdas individuais de
sensibilidade ao contraste espacial de luminância. Entretanto, perdas individuais da
capacidade de discriminação de cores e alterações individuais dos limiares de discriminação
de cores em todos os eixos de confusão (protanópico, deuteranópico e tritanópico) foram
detectadas. Deste modo, conclui-se que a visão de cores é um parâmetro sensorial cuja
medida pode ser útil na avaliação do estado pós-cirúrgico dos pacientes acometidos com
aneurisma intracraniano do sistema carotídeo. / The intracranial saccular aneurysms constitute the main cause of spontaneous meningeal or
subarachnoid hemorrhage. The complications derived from the sprouting of such aneurysms
hemorrhage, classified as sensorial (acuity and visual field), motor (motility of extra-ocular
muscle), and perceptual, are considered as well studied by neurosurgery due to relative
similarity between cases. However, little is known about possible postoperative perceptual
and cognitive alterations. In the present study, the visual sensitivity of patients in
postoperative condition of intracranial aneurysm of the carotid system to achromatic and
chromatic spatial stimuli was evaluated. The contrast sensitivity to luminance spatial gratings
was measured in eleven spatial frequencies (0,2, 0,5, 0,8, 1, 2, 4, 8, 10, 15, 20, and 30
cycles/degree). The color discrimination ability was measured by a version of the Farnsworth-
Munsell test with 85 hues, divided in four series of stimuli presented sequentially, being one
serie with 22 stimuli and three series with 24 stimuli. For the measure of color discrimination
thresholds, 5 MacAdam’s ellipses were determined and, for each one of them, discrimination
thresholds had been measured in 20 directions of the CIE 1976 color space, through the test of
Mollon-Reffin. The studied variables were compared with the statistical norms of agematched
control subjects. The results show that, individually, there are not significant losses
of spatial contrast sensitivity. However, individual losses in color discrimination ability and
individual alterations in color discrimination thresholds in all color confusion axis
(protanopic, deuteranopic and tritanopic) were detected. Thus, it can be concluded that color
vision have sensorial parameters which measurement can be useful in the evaluation of
patients postoperative of intracranial aneurysm of the carotid system.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/9278 |
Date | 01 July 2017 |
Creators | BASTOS, Albedy Moreira |
Contributors | SILVEIRA, Luiz Carlos de Lima, RODRIGUES, Anderson Raiol |
Publisher | Universidade Federal do Pará, Programa de Pós-Graduação em Neurociências e Biologia Celular, UFPA, Brasil, Instituto de Ciências Biológicas |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0029 seconds