Return to search

Desenvolvimento de um sistema multiconversor para a realização de estudos experimentais em microrredes de corrente contínua

Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-02-10T18:22:13Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolvimentoSistemaMulticonversor.pdf: 3500266 bytes, checksum: 571c3ede894fd99997fdbd62bf7f9992 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-02-14T14:40:33Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolvimentoSistemaMulticonversor.pdf: 3500266 bytes, checksum: 571c3ede894fd99997fdbd62bf7f9992 (MD5) / Made available in DSpace on 2017-02-14T14:40:33Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolvimentoSistemaMulticonversor.pdf: 3500266 bytes, checksum: 571c3ede894fd99997fdbd62bf7f9992 (MD5)
Previous issue date: 2015-08-10 / Neste trabalho, é apresentado o projeto e desenvolvimento de um Sistema Multiconversor, baseado em uma Microrrede com barramento em corrente contínua e conversores estáticos CC-CC e CC-CA. Este sistema está localizado no Laboratório de Controle em Sistemas de Potência (LACSPOT) na Universidade Federal do Pará (UFPA).
O Sistema Multiconversor consiste de três conversores estáticos, sendo dois na topologia abaixador Buck e o terceiro um inversor trifásico. O primeiro conversor alimenta um barramento de corrente contínua com tensão controlada, o qual fornece tensão para um segundo conversor Buck.
No segundo conversor, é aplicada uma estratégia de controle de tensão de forma a manter a potência constante. O inversor também é alimentado através do barramento CC e pode ser conectado à rede elétrica de forma a permitir a realização de estudos com sistemas interligados e geração distribuída.
Para a validação dos conversores Buck estudados neste trabalho, foram desenvolvidos controladores digitais, através do método indireto de projeto de controladores digitais. Ambos os controladores foram desenvolvidos a partir da leitura das tensões na saída dos dois conversores, com o intuito de manter a tensão e a potência constantes nos conversores primário e secundário, respectivamente.
Além da dificuldade inerente de sistemas com incertezas no modelo matemático e não linearidades presentes em conversores estáticos, o conversor com controle de tensão alimenta o segundo conversor. Isto introduz características não lineares que podem, inclusive, provocar instabilidade na tensão do barramento. Por esse motivo, faz-se necessário desenvolver uma estratégia de controle com o intuito de se manter a tensão no barramento o mais próximo possível da tensão de referência.
Por fim, uma série de testes é realizada tanto em simulação computacional, quanto no sistema real, com o intuito de verificar a eficácia das técnicas de controle estudadas e aplicadas. Os resultados obtidos mostram o bom desempenho da estratégia de controle para o Sistema Multiconversor. / This paper presents the design and development of a Multiconverter System based on a Microgrid comprised of a DC bus and static power converters DC-DC and DC-AC. This system is located at the Power Systems Control Laboratory (LACSPOT) at Federal University of Pará (UFPA).
The Multiconverter System consists in three power converters, two in step-down Buck topology and the third a three-phase inverter. The first converter feeds a direct current voltage controlled bus that provides voltage to a second Buck converter.
On the second Buck converter is also applied a voltage control strategy in order to maintain a constant power supply. The three-phase inverter is also powered by a DC bus can be connected to the local power grid, allowing studies with grid-tied systems and distributed generation.
To test the buck converter studied in this work, were developed digital controllers, based on indirect digital control design method. Both controllers were developed using the output voltages as feedback signals in order to maintain the voltage and power as constant as possible, on the primary and secondary converters, respectively. Besides inner difficult in systems with parametric uncertainties and nonlinearities shown in power converters, the power converter with voltage control also feeds the second power converter. That introduces non-linear characteristics that may cause bar voltage instability. For that reason, it is necessary to develop a control strategy with the goal of keeping the voltage near to the voltage bus reference. To sum up, several tests were performed both in computer simulation, as in the real system in order to check the effectiveness of control techniques studied and applied. The obtained results shown that the Multiconverter System was able to provide a good performance under the designed control strategy.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/7673
Date10 August 2015
CreatorsCOSTA JUNIOR, Fernando José da
ContributorsBARRA JUNIOR, Walter
PublisherUniversidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0019 seconds