Spelling suggestions: "subject:"cistema multiconversores"" "subject:"cistema multiconverter""
1 |
Desenvolvimento de um sistema multiconversor para a realização de estudos experimentais em microrredes de corrente contínuaCOSTA JUNIOR, Fernando José da 10 August 2015 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-02-10T18:22:13Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolvimentoSistemaMulticonversor.pdf: 3500266 bytes, checksum: 571c3ede894fd99997fdbd62bf7f9992 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-02-14T14:40:33Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolvimentoSistemaMulticonversor.pdf: 3500266 bytes, checksum: 571c3ede894fd99997fdbd62bf7f9992 (MD5) / Made available in DSpace on 2017-02-14T14:40:33Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolvimentoSistemaMulticonversor.pdf: 3500266 bytes, checksum: 571c3ede894fd99997fdbd62bf7f9992 (MD5)
Previous issue date: 2015-08-10 / Neste trabalho, é apresentado o projeto e desenvolvimento de um Sistema Multiconversor, baseado em uma Microrrede com barramento em corrente contínua e conversores estáticos CC-CC e CC-CA. Este sistema está localizado no Laboratório de Controle em Sistemas de Potência (LACSPOT) na Universidade Federal do Pará (UFPA).
O Sistema Multiconversor consiste de três conversores estáticos, sendo dois na topologia abaixador Buck e o terceiro um inversor trifásico. O primeiro conversor alimenta um barramento de corrente contínua com tensão controlada, o qual fornece tensão para um segundo conversor Buck.
No segundo conversor, é aplicada uma estratégia de controle de tensão de forma a manter a potência constante. O inversor também é alimentado através do barramento CC e pode ser conectado à rede elétrica de forma a permitir a realização de estudos com sistemas interligados e geração distribuída.
Para a validação dos conversores Buck estudados neste trabalho, foram desenvolvidos controladores digitais, através do método indireto de projeto de controladores digitais. Ambos os controladores foram desenvolvidos a partir da leitura das tensões na saída dos dois conversores, com o intuito de manter a tensão e a potência constantes nos conversores primário e secundário, respectivamente.
Além da dificuldade inerente de sistemas com incertezas no modelo matemático e não linearidades presentes em conversores estáticos, o conversor com controle de tensão alimenta o segundo conversor. Isto introduz características não lineares que podem, inclusive, provocar instabilidade na tensão do barramento. Por esse motivo, faz-se necessário desenvolver uma estratégia de controle com o intuito de se manter a tensão no barramento o mais próximo possível da tensão de referência.
Por fim, uma série de testes é realizada tanto em simulação computacional, quanto no sistema real, com o intuito de verificar a eficácia das técnicas de controle estudadas e aplicadas. Os resultados obtidos mostram o bom desempenho da estratégia de controle para o Sistema Multiconversor. / This paper presents the design and development of a Multiconverter System based on a Microgrid comprised of a DC bus and static power converters DC-DC and DC-AC. This system is located at the Power Systems Control Laboratory (LACSPOT) at Federal University of Pará (UFPA).
The Multiconverter System consists in three power converters, two in step-down Buck topology and the third a three-phase inverter. The first converter feeds a direct current voltage controlled bus that provides voltage to a second Buck converter.
On the second Buck converter is also applied a voltage control strategy in order to maintain a constant power supply. The three-phase inverter is also powered by a DC bus can be connected to the local power grid, allowing studies with grid-tied systems and distributed generation.
To test the buck converter studied in this work, were developed digital controllers, based on indirect digital control design method. Both controllers were developed using the output voltages as feedback signals in order to maintain the voltage and power as constant as possible, on the primary and secondary converters, respectively. Besides inner difficult in systems with parametric uncertainties and nonlinearities shown in power converters, the power converter with voltage control also feeds the second power converter. That introduces non-linear characteristics that may cause bar voltage instability. For that reason, it is necessary to develop a control strategy with the goal of keeping the voltage near to the voltage bus reference. To sum up, several tests were performed both in computer simulation, as in the real system in order to check the effectiveness of control techniques studied and applied. The obtained results shown that the Multiconverter System was able to provide a good performance under the designed control strategy.
|
2 |
Performance evaluation of robust parametric control strategies applied on suppression of oscillations effects due to constant power loads in multi-converter buck-buck systems / Avaliação de desempenho de estratégias de controle paramétrico robusto aplicadas na supressão de efeitos de oscilações devido a cargas de potência constantes em sistemas de buck-buck multi-conversorMARCILLO, Kevin Eduardo Lucas 11 June 2018 (has links)
Submitted by Luciclea Silva (luci@ufpa.br) on 2018-09-25T17:40:10Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_Perfomanceevaluationrobust.pdf: 5317740 bytes, checksum: 4bd1f1a3fd9e888155a633221aa5e096 (MD5) / Approved for entry into archive by Luciclea Silva (luci@ufpa.br) on 2018-09-25T17:40:47Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_Perfomanceevaluationrobust.pdf: 5317740 bytes, checksum: 4bd1f1a3fd9e888155a633221aa5e096 (MD5) / Made available in DSpace on 2018-09-25T17:40:47Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_Perfomanceevaluationrobust.pdf: 5317740 bytes, checksum: 4bd1f1a3fd9e888155a633221aa5e096 (MD5)
Previous issue date: 2018-06-11 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Conversores chaveados são sistemas amplamente utilizadas em aplicações industriais. Tais sistemas operam via controle em malha fechada e, dessa forma, os aspectos de estabilidade e desempenho em malha fechada devem ser assegurados pelo projetista. Recentemente, o emprego de sistemas com múltiplos conversores vem se tornando comum em uma ampla gama de aplicações. A interação entre os sistemas de controle os múltiplos conversores pode levar o sistema a operar com reduzidas margens de estabilidade ou com um baixo desempenho dinâmico. Portanto, a estabilidade de um sistema com conversores operando em cascata é uma grande preocupação para aplicações reais. A instabilidade em sistemas em cascata pode ocorrer devido à carga de potência constante (CPL), que é um comportamento dos conversores quando se encontram regulados. As CPLs exibem comportamento de resistência negativa incremental, causando um alto risco de instabilidade em conversores interligados. Dessa forma, a mitigação desse problema é uma questão importante no projeto da fonte de alimentação comutada de múltiplos estágios, de modo a garantir a estabilidade de todo o sistema. No entanto, algumas dificuldades estão presentes além da CPL, por exemplo, não linearidades fortes, devido à presença do elemento indutivo, além das incertezas em relação aos valores nominais dos componentes discretos que compõem o sistema. Neste trabalho é realizado um estudo experimental do desempenho das metodologias de controle robusto paramétrico aplicadas ao problema de mitigar o efeito adverso de cargas do tipo CPL, em um sistema com dois conversores buck operando em cascata (sistema buck-buck). Vários testes foram desenvolvidos utilizando tanto uma planta experimental quanto via simulação computacional em Matlab/ Simulink, quando o sistema multiconversor buck-buck é submetido a uma variação de potência. Os resultados mostram o melhor desempenho das metodologias propostas. / Multi-converter electronic systems are becoming widely used in many industrial applications; therefore, the stability of the cascaded system is a big concern to real-world power supplies applications. Instability in cascaded systems may occur due to the constant power load (CPL), which is a behavior of the tightly regulated converters. CPLs exhibit incremental negative resistance behavior causing a high risk of instability in interconnected converters; therefore, the mitigation of this problem is an important issue in the multiple-stage switched mode power supply design. Thus, it is important to guarantee stability of the whole system. However, some difficulties remains besides the CPL, e.g., non-linearities due to the inductive element and uncertainties due to imprecision of mathematical models and/or variation of nominal values of the discrete elements that compose the DC/DC buck converter. Aiming to evaluate the performance of the proposed robust methodologies in this work to mitigate the instability problem caused by a CPL, several tests were developed by using an experimental plant and Matlab/Simulink, when the multi-converter buck-buck system is subjected a variation of power reference. The results show the improved performance of the proposed methodologies.
|
Page generated in 0.3992 seconds