• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Performance evaluation of robust parametric control strategies applied on suppression of oscillations effects due to constant power loads in multi-converter buck-buck systems / Avaliação de desempenho de estratégias de controle paramétrico robusto aplicadas na supressão de efeitos de oscilações devido a cargas de potência constantes em sistemas de buck-buck multi-conversor

MARCILLO, Kevin Eduardo Lucas 11 June 2018 (has links)
Submitted by Luciclea Silva (luci@ufpa.br) on 2018-09-25T17:40:10Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Perfomanceevaluationrobust.pdf: 5317740 bytes, checksum: 4bd1f1a3fd9e888155a633221aa5e096 (MD5) / Approved for entry into archive by Luciclea Silva (luci@ufpa.br) on 2018-09-25T17:40:47Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Perfomanceevaluationrobust.pdf: 5317740 bytes, checksum: 4bd1f1a3fd9e888155a633221aa5e096 (MD5) / Made available in DSpace on 2018-09-25T17:40:47Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Perfomanceevaluationrobust.pdf: 5317740 bytes, checksum: 4bd1f1a3fd9e888155a633221aa5e096 (MD5) Previous issue date: 2018-06-11 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Conversores chaveados são sistemas amplamente utilizadas em aplicações industriais. Tais sistemas operam via controle em malha fechada e, dessa forma, os aspectos de estabilidade e desempenho em malha fechada devem ser assegurados pelo projetista. Recentemente, o emprego de sistemas com múltiplos conversores vem se tornando comum em uma ampla gama de aplicações. A interação entre os sistemas de controle os múltiplos conversores pode levar o sistema a operar com reduzidas margens de estabilidade ou com um baixo desempenho dinâmico. Portanto, a estabilidade de um sistema com conversores operando em cascata é uma grande preocupação para aplicações reais. A instabilidade em sistemas em cascata pode ocorrer devido à carga de potência constante (CPL), que é um comportamento dos conversores quando se encontram regulados. As CPLs exibem comportamento de resistência negativa incremental, causando um alto risco de instabilidade em conversores interligados. Dessa forma, a mitigação desse problema é uma questão importante no projeto da fonte de alimentação comutada de múltiplos estágios, de modo a garantir a estabilidade de todo o sistema. No entanto, algumas dificuldades estão presentes além da CPL, por exemplo, não linearidades fortes, devido à presença do elemento indutivo, além das incertezas em relação aos valores nominais dos componentes discretos que compõem o sistema. Neste trabalho é realizado um estudo experimental do desempenho das metodologias de controle robusto paramétrico aplicadas ao problema de mitigar o efeito adverso de cargas do tipo CPL, em um sistema com dois conversores buck operando em cascata (sistema buck-buck). Vários testes foram desenvolvidos utilizando tanto uma planta experimental quanto via simulação computacional em Matlab/ Simulink, quando o sistema multiconversor buck-buck é submetido a uma variação de potência. Os resultados mostram o melhor desempenho das metodologias propostas. / Multi-converter electronic systems are becoming widely used in many industrial applications; therefore, the stability of the cascaded system is a big concern to real-world power supplies applications. Instability in cascaded systems may occur due to the constant power load (CPL), which is a behavior of the tightly regulated converters. CPLs exhibit incremental negative resistance behavior causing a high risk of instability in interconnected converters; therefore, the mitigation of this problem is an important issue in the multiple-stage switched mode power supply design. Thus, it is important to guarantee stability of the whole system. However, some difficulties remains besides the CPL, e.g., non-linearities due to the inductive element and uncertainties due to imprecision of mathematical models and/or variation of nominal values of the discrete elements that compose the DC/DC buck converter. Aiming to evaluate the performance of the proposed robust methodologies in this work to mitigate the instability problem caused by a CPL, several tests were developed by using an experimental plant and Matlab/Simulink, when the multi-converter buck-buck system is subjected a variation of power reference. The results show the improved performance of the proposed methodologies.
2

Projeto e avaliação experimental de uma estratégia baseada em análise intervalar aplicada ao projeto de estabilizador de sistemas de potência robusto implementado em um sistema de geração de 10KVA

COSTA, Cleyson Amorim 12 1900 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-03-07T15:58:58Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_ProjetoAvaliacaoExperimental.pdf: 1801259 bytes, checksum: 4031abdf53d2619b2e814c79172b0343 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-05-15T12:54:23Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_ProjetoAvaliacaoExperimental.pdf: 1801259 bytes, checksum: 4031abdf53d2619b2e814c79172b0343 (MD5) / Made available in DSpace on 2014-05-15T12:54:23Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_ProjetoAvaliacaoExperimental.pdf: 1801259 bytes, checksum: 4031abdf53d2619b2e814c79172b0343 (MD5) Previous issue date: 2013 / Neste trabalho, são apresentados a metodologia de projeto e resultados de testes experimentais de um estabilizador de sistema de potência (ESP), implementado em um sistema de geração em escala reduzida de 10 kVA, localizado no Laboratório de Controle e Sistema de Potência (LACSPOT) da Universidade Federal do Pará (UFPA). O projeto do ESP é baseado em uma estratégia de controle robusto com ênfase em incertezas paramétricas estruturadas, as quais são tratadas com ferramentas da teoria de análise intervalar. Estas incertezas são decorrentes de mudanças do ponto de operação do sistema, que provocam variações nos parâmetros de um modelo matemático linearizado referente ao comportamento dinâmico do sistema elétrico de potência no referido ponto de operação. Para o projeto do ESP robusto intervalar, são realizados uma serie de ensaios experimentais com o propósito de estimar os parâmetros de modelos linearizados da planta, representando satisfatoriamente a dinâmica dos modos poucos amortecidos do sistema de geração interligado. O método de identificação é baseado em técnica de identificação paramétrica, baseado em mínimos quadrados. A partir de um conjunto de dados de entrada e saída, para cada ponto de operação, um modelo linear, do tipo auto-regressivo com entrada exógenos (ARX), estimado para fim de uso do projeto do ESP. Por fim, uma série de testes experimentais é realizada no sistema de geração interligado a rede elétrica local, com o propósito de verificar a efetividade da técnica de controle robusto intervalar proposta para a sintonia do ESP. A partir da análise da função custo do sinal de erro de desvio de potência elétrica na saída do gerador síncrono e a função custo do sinal de controle do ESP comprova-se experimentalmente o bom desempenho obtido pela técnica de controle proposta em comparação com uma técnica de controle clássica. / In this paper, are presented the design methodology and the experimental test results of a power system stabilizer (PSS), implemented in a small-scale generation system of 10 kVA, located in the Control and Power System Laboratory (LACSPOT) at the Para Federal University (UFPA). The PSS design is based on a robust control strategy with emphasis on the structured parametric uncertainties, which are treated with tools of the interval analysis theory. These uncertainties are arising from the system operation point, which cause variations in the parameters of a linearized mathematical model referent on the dynamic behavior of the power electric system in the operation point. For the interval robust PSS design, are performed experimental tests with the purpose of estimating the linearized plant models parameters, representing the low damped modes dynamic of the interconnected generation system. The identification method is based on parametric identification technique based on least squares. From a set of input and output data, for each operation point, a ARX linear model is estimated with the purposed of the PSS design. Finally, a set of experimental tests is performed in the interconnected generation system, with the purpose of analyze the effectiveness of the interval robust control technique proposed to the PSS design. From the analysis of the active power deviation signal cost function at the synchronous generator terminal and the PSS control signal cost function, proves experimentally the good performance achieved by robust control technique proposed in comparison with a classic control technique.

Page generated in 0.1016 seconds