Return to search

Simulação e análise do desempenho termodinâmico de sistemas de refrigeração por absorção com diferentes configurações / Simulation and analysis of the thermodynamic performance of absorption refrigeration systems with different configurations

Orientador: José Vicente Hallak d'Angelo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-23T08:54:55Z (GMT). No. of bitstreams: 1
Araujo_HugoValenca_M.pdf: 2457535 bytes, checksum: cf5a800ee51a5605b7d2cd69248ef52c (MD5)
Previous issue date: 2013 / Resumo: A refrigeração e o condicionamento de ar representam um campo tecnológico em potencial para a adoção de medidas de economia de eletricidade. Nesse sentido, Sistemas de Refrigeração por Absorção (SRAs) figuram como uma opção interessante por serem adequados à produção de frio mediante um gasto significativamente menor de energia elétrica em comparação a Sistemas de Refrigeração por Compressão Mecânica (SRCMs) de vapor. Com a finalidade de gerar o efeito de refrigeração, o SRCM realiza uma compressão mecânica de vapor à custa do consumo de trabalho elétrico em um compressor; em contrapartida, a compressão no SRA é de natureza termofísica/química e promovida por energia térmica. No segmento de açúcar e álcool brasileiro, a etapa determinante da produção de etanol a partir da cana consiste na fermentação alcoólica do mosto em dornas. Tal etapa é exotérmica e, uma vez que a elevação descontrolada da temperatura desfavorece a produção de álcool, há a necessidade de remover o calor gerado por meio do resfriamento do meio em fermentação. Dessa forma, o objetivo geral do presente trabalho foi simular e analisar o desempenho termodinâmico (energético, COP, e exergético, ?ex) de SRAs com diferentes configurações, trabalhando com o par água/brometo de lítio (H2O/LiBr) e que satisfaçam a carga de refrigeração demandada por um processo fermentativo. Adicionalmente, um dos objetivos específicos foi investigar o risco de ocorrência da cristalização do LiBr, a qual resulta em depósitos, com o auxílio da curva de equilíbrio sólido-líquido (solubilidade) do par H2O/LiBr. As análises dos efeitos de variáveis de projeto e operação (realizadas no software Engineering Equation Solver - EES) demonstraram que os valores de COP das configurações de SRAs de duplo efeito são significativamente maiores do que aquele da configuração de simples efeito; no entanto, as eficiências exergéticas de todas as configurações são equiparáveis, o que pode ser atribuído à quantidade e à qualidade da energia térmica consumida nos respectivos geradores de primeiro efeito. Baixos desempenhos de Segunda Lei são devidos principalmente ao absorvedor, pois esse equipamento apresenta os maiores defeitos de eficiência em todos os SRAs estudados. Adicionalmente, avaliou-se a dependência do desempenho termodinâmico quanto às efetividades de trocadores de calor intermediários, a diferenças de pressão operacional e à cessão direta de calor externo a geradores de segundo efeito. Entre outros resultados, observou-se a existência de máximos do COP e da ?ex em função da temperatura no gerador de primeiro efeito. No que se refere à possibilidade de precipitação do LiBr, verificou-se menor iminência no SRA de duplo efeito com fluxo em paralelo. Em particular, observou-se que aumentos excessivos da temperatura no gerador de primeiro efeito, além de não favorecerem o desempenho termodinâmico, tornam o risco de cristalização do LiBr mais significativo / Abstract: Refrigeration and air conditioning represent a potential technological field for the adoption of measures to save electricity. In this way, Absorption Refrigeration Systems (ARSs) are an interesting option because they are suitable for the production of cold utilities with a significantly lower cost of electric power compared to Mechanical Compression Refrigeration Systems (MCRSs). In order to generate the cooling effect, the MCRS performs a mechanical vapor compression at the expense of the consumption of electrical work in a compressor. On the other side, the nature of the compression in ARSs is thermo physical/chemical and this process is promoted by thermal energy. In the Brazilian sugar and ethanol industry, the main stage of ethanol production from sugarcane is the alcoholic fermentation in vats. This stage is exothermic and since the uncontrolled elevation of temperature results in disadvantages to the ethanol production, it is necessary to remove the heat generated by the cooling of the fermentation medium. Thus, the general objective of this study was to simulate and analyze the thermodynamic performance (energy, COP, and exergy, ?ex) of ARSs with different configurations, working with the water/lithium bromide (H2O/LiBr) mixture, and satisfying the cooling load demanded by a fermentation process. Additionally, one of the specific objectives was to investigate the risk of LiBr crystallization, resulting in deposits, with the aid of the solid-liquid equilibrium (solubility) curve of the H2O/LiBr mixture. Analyses of the effects of design and operating variables (executed in the software Engineering Equation Solver - EES) have shown that the values of COP of the double effect configurations are significantly greater than that of the simple effect configuration; however, the exergetic efficiencies of all configurations are comparable, which can be attributed to the quantity and the quality of the energy consumed in the respective first effect generators. Low Second Law performances are mainly due to the absorber because this equipment has the highest efficiency defects in all ARSs studied. Additionally, it was evaluated the dependence of the thermodynamic performance regarding to the effectivenesses of intermediate heat exchangers, the differences in operating pressures and the direct supply of external heat to second effect generators. Among other findings, it was observed the existence of maximums of COP and ?ex as functions of the temperature in the first effect generator. With regard to the possibility of LiBr precipitation, it was verified lower imminence in the double effect ARS with parallel flow. In particular, it was observed that excessive rises in the temperature in the first effect generator, besides not favor the thermodynamic performance, makes the risk of LiBr crystallization more significant / Mestrado / Sistemas de Processos Quimicos e Informatica / Mestre em Engenharia Química

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/266566
Date08 January 2013
CreatorsAraújo, Hugo Valença, 1988-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, D'Angelo, José Vicente Hallak, 1967-, Zemp, Roger Josef, Meirelles, Antonio Jose de Almeida
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Química, Programa de Pós-Graduação em Engenharia Química
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format139 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds