Orientador: Maria Clara Filippini Ierardi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-05T03:51:08Z (GMT). No. of bitstreams: 1
Larosa_MariaAparecida_M.pdf: 7133035 bytes, checksum: 21dc117acd3886e58c2819ef437c2d52 (MD5)
Previous issue date: 2005 / Resumo: No presente trabalho, os aços inoxidáveis austenítico AISI 304 e martensítico AISI 420, empregados na fabricação de instrumentais cirúrgicos, foram submetidos a tratamentos superficiais a laser sem e com fusão, com o intuito de analisar as modificações microestruturais resultantes destes tratamentos e, conseqüentemente, seus efeitos na resistência à corrosão destes
aços. A caracterização microestrutural foi feita por' microscopia óptica, microscopia eletrônica de varredura, microdureza Vickers, difração de raios-X e espectroscopia de energia dispersiva. Para analisar o comportamento à corrosão dos aços, antes e após os tratamentos, foram realizados ensaios eletroquímicos usando como eletrólitos água e detergentes enzimáticos, sendo estes
utilizados na limpeza de instrumentais cirúrgicos. Após os tratamentos a laser, o aço austenítico refundido apresentou uma microestrutura refinada constituída por dendritas de austenita, porém sem um aumento significativo de dureza, mas com melhoria frente à corrosão. A estrutura do aço martensítico tratado a laser é formada por martensita, austenita residual e carbonetos dos tipos Cr7C3e Cr23C6. A dureza do aço AISI 420 aumentou significativamente mas houve uma perda na resistência à corrosão devido à precipitação de carbonetos / Abstract: In this work, the austenitic AISI 304 and martensitic AISI 420 stainless steels, used in surgical instruments fabrication were submitted to laser surface treatments with and without melting. The purpose is analyse the microstructural changes resulting from laser treatments and, consequently, their effects on the corrosion resistance. The microstructural characterization was
performed by optical microscopy, scanning electronic microscopy, Vickers microhardness, X-ray diffraction and energy dispersive spectroscopy. In order to analyze the corrosion behavior electrochemical tests were carried out before and afier treatments. The electrolytes consisted of water and enzymatic detergents that are used in the c1eaning procedures of the surgical instruments. After laser treatments, the remelted austenitic steel presented a refined microstructure composed of austenite dendrites. No significant hardness increase was observed. Further, corrosion resistance was improved. The structure of the treated martensitic steel
consisted of martensite, residual austenite and carbides type Cr7C3 and Cr23C6. The AISI 420 steel hardness increased significantly but the corrosion resistance was decreased by carbides precipitation / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/263544 |
Date | 27 July 2005 |
Creators | Larosa, Maria Aparecida |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Ierardi, Maria Clara Filippini, 1951-, Mei, Paulo Roberto, Andrade, Aron José Pazin de |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Programa de Pós-Graduação em Engenharia Mecânica |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 101f. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.003 seconds