Return to search

Estudo comparativo da degradação de forças geradas por elásticos ortodônticos sintéticos e molas de níquel-titânio

Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-05-19Bitstream added on 2014-06-13T20:01:53Z : No. of bitstreams: 1
araujo_fbc_dr_sjc.pdf: 312103 bytes, checksum: 3f21d0423598e73724ad1f5cf82e2469 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Analisaram-se separada e comparativamente três marcas comerciais de elásticos ortodônticos sintéticos e de molas de NiTi (MORELLI, ORMCO e GAC), quanto à degradação da força sofrida por estes materiais em função do tempo, quando submetidos a simulação das condições bucais. Os elásticos e molas foram inicialmente termociclados (temperaturas de 15°C e 45°C), em seguida estirados em 20mm, imersos em saliva artificial a 37°C e desativados em 0,5mm semanais. As leituras da quantidade de força gerada pelas amostras foram realizadas nos momentos: inicial, 1, 24, 48 horas, 7, 14, 21 e 28 dias. Observou-se significativa redução na quantidade de força gerada pelos elásticos na primeira hora de ativação, que variou de 49,5% a 53%, enquanto que para as molas a degradação foi signicativamente menor, com valores entre 4,2% e 18,1%. Ao término de 28 dias de testes, as amostras de elásticos sofreram redução média na quantidade de força gerada entre 82,7% e 91,2% (GAC-82,7%, ORMCO-86,0% e MORELLI- 91,2%) já as amostras de molas apresentaram degradação média de força entre 17,5% e 32,2% (MORELLI-17,5%, ORMCO-27,3% e GAC-32,2%). Concluiu-se que, em geral, os elásticos promoveram maior índice inicial de força que as molas, mas após as primeiras 24 horas de ativação a quantidade de força gerada pelos elásticos era menor que a promovida pelas molas, que assim apresentaram níveis médios de força mais constantes que os elásticos ao longo dos testes. / Three commercial marks of synthetic elastics and NiTi coil springs (MORELLI, ORMCO, GAC) were separately and comparably analyzed, according to the force degradation generated by these materials, because of the time, when maintained stretched in artificial salivary, 37°C. The synthetic elastics and NiTi coil springs were thermal- cycled (15°C-45°C) and stretched in 20mm, and this stretch was reduced in 0,5mm weekly. The readings of the amount generated for elastics and coil springs were done in the intervals 0, 1, 24, 48h, 7, 14, 21 and 28 days. Where observed significative reduction on the amount of force generated for the elastics in the first hour of the activation (49,5%- 53%), and 82,7% - 91,2% in 28 days of the tests ( MORELLI - 91,2%, ORMCO - 86,0%, GAC - 82,7%);, while the generated force for NiTi coil springs suffered a reduction of 4,2%- 18,1%, in the first hour of the experimentation and 17,5% - 32,2% in 28 days of the stretch (MORELLI - 17,5%, ORMCO - 27,3%, GAC - 32,2%). We conclude that for most elastics delivered larger initial force that NiTi coil springs, but after 24 hours of activation the NiTi coil springs delivered larger force that the elastics and generated level of the force more constant that elastics.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/101345
Date19 May 2006
CreatorsAraujo, Fabiana Ballete de Cara [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Ursi, Weber José da Silva [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format98 f. : il. anexo
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0022 seconds