• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 6
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Movimento distal de caninos ectópicos com a aparatologia móvel

Kinceler, José January 1983 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-15T21:58:07Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T14:38:16Z : No. of bitstreams: 1 310131.pdf: 47677203 bytes, checksum: 60b5289084ebc5acfb27748a7143b133 (MD5)
2

Avaliação das alterações transversais imediatas à expansão maxilar com o aparelho quadrihélice por meio de tomografia computadorizada do feixe cônico

Zasso, Manuela Batistella January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:39:10Z (GMT). No. of bitstreams: 1 325084.pdf: 1222321 bytes, checksum: 566d4ad956f3872dce1fd2737e54586d (MD5) Previous issue date: 2013 / O objetivo deste estudo clínico prospectivo foi avaliar as alterações esqueléticas transversais imediatas à expansão maxilar lenta (EML) utilizando o aparelho quadrihélice em pacientes com dentição mista através de tomografia computadorizada do feixe cônico (TCFC). Métodos: A amostra consistiu de 27 pacientes com idades entre 7 a 10 anos que utilizaram o aparelho quadrihélice ativado em 8mm e realizaram TCFC antes da instalação dos expansores (T1) e seis meses após (T2). A análise da diferença entre os tempos foi realizada através do teste t de Student para dados pareados, considerando p0,05. Resultados: Na base maxilar não ocorreram mudanças estatisticamente significativas, exceto para a região de molares em vista axial e coronal. Na crista óssea alveolar, todas as variáveis apresentaram aumento estatisticamente significativo (p0,05). Conclusões: A EML utilizando o quadrihélice provocou aumento estatisticamente significativo na base maxilar somente em região de molares, porém clinicamente sem expressão, e aumento transversal da crista óssea alveolar com inclinação dentária. A expansão em nível de crista óssea foi maior que em base maxilar. O quadrihélice não apresentou resultados ortopédicos satisfatórios, mas corrigiu a mordida cruzada em todos os pacientes deste estudo.<br> / Abstract : The purpose of this prospective clinical study was to evaluate the transverse skeletal and dentoalveolar changes immediately slow maxillary expansion ( SME) using the Quad-helix appliance in patients with mixed dentition through beam computed tomography (CBCT ). Methods: A sample of 27 subjects with transverse maxillary deficiency used a quad-helix appliance activated at 8mm, divided into four activations of 2 mm. Cone-beam computed tomography scans were taken before expansion (T1) and six months later (T2). Data were compared by using the Student paired t test to identify statistically significant differences (P<0.05). Results: At the maxillary base there were statistically significant changes, except for the first molar in axial and coronal views. In the alveolar crest, all variables showed a statistically significant increase (p<0.05). Conclusions: The EML using the Quad-helix caused statistically significant increase in the maxillary base at the molar region, but without clinically expression, and presented a transversal increased at the alveolar bone crest with tooth inclination. The expansion in crestal bone level was higher than in maxillary base. The Quad-helix not presented satisfactory orthopedic results, but corrected the crossbite in all patients in this study.
3

Estudo clínico comparativo dos efeitos de dois tipos de recuperadores de espaço removíveis inferiores

Costa, Carolina Covolo da January 2001 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Curso de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-18T13:14:04Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T21:28:50Z : No. of bitstreams: 1 179590.pdf: 3087231 bytes, checksum: c42ac3a21f05a8b157fd07a64ebc66a7 (MD5) / Com o objetivo de avaliar comparativamente os resultados obtidos pela utilização de recuperadores de espaço removíveis em 20 crianças com perdas precoces, uni ou bilaterais, de molares decíduos inferiores, 15 casos foram tratados com o sela fendida e 16, com o parafuso distalizador. Verificou-se que não houve diferença estatística quanto ao espaço recuperado pelos dispositivos, porém, como o parafuso distalizador foi usado por um menor período de tempo, a sua velocidade de recuperação de espaço foi estatisticamente superior a do sela fendida. Também evidenciou-se que ambos os dispositivos provocaram inclinação vestibular dos incisivos e, distal dos primeiros molares permanentes. A ocorrência de lesão na mucosa bucal foi evidenciada apenas em crianças com perdas bilaterais e presença de grampo circunferencial no aparelho. Foi possível concluir que o parafuso distalizador deve ser priorizado nos casos em que o fator tempo se faz relevante.
4

Análise das angulações mésio-distais de bráquetes pré-ajustados

Verri, Ana Caroline Gonçales [UNESP] 09 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-09Bitstream added on 2014-06-13T18:32:09Z : No. of bitstreams: 1 verri_acg_me_araca.pdf: 260280 bytes, checksum: f287c562e46cbb8512f0d04de04dec90 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: O objetivo do presente estudo foi comparar as angulações dos bráquetes metálicos pré-ajustados da prescrição Roth de incisivos centrais e caninos superiores esquerdos. Materiais e Método: Para o estudo foram selecionados 10 bráquetes, de três marcas disponíveis no mercado: GAC, Forestadent e Morelli. Foram confeccionadas duas matrizes para permitir o posicionamento padronizado dos dentes e bráquetes. A captura das imagens foi realizada a partir de fotografia orto-radial padronizada, por meio de máquina fotográfica digital, exportadas e mensuradas com o programa Image J. Resultados: Os resultados foram submetidos à análise estatística por meio da Análise de Variância (ANOVA), seguido pelo teste Tukey ao nível de significância de 5%. Os bráquetes dos incisivos centrais superiores esquerdos mostraram diferenças estatisticamente significantes entre os seguintes grupos: MOR1 em relação ao GAC1; e FOR1 em relação ao GAC1. Nos caninos superiores esquerdos as diferenças estatisticamente significantes foram entre os grupos: MOR3 em relação ao GAC3; e MOR3 em relação ao FOR3. Conclusão: Com base nos resultados pode-se concluir que, a despeito da mesma denominação para a prescrição, entre marcas diferentes, as angulações não são iguais / Objective: The aim of this study was to compare the slot angulations of the pre-adjusted Roth prescription metallic brackets of left central maxillary incisors and left maxillary canines. Materials and Method: Ten brackets of three commercial brands were selected for this study: GAC, Forestadent and Morelli. Two individual metal matrix for brackets and tooth positioning were made for each teeth group. The captured images were made from standardized photography ortho-radial through digital camera, exported and measured with the software Image J. Results: One-way ANOVA and Tukey statistical analysis at 5% of significance level were performed. The results showed statistically significant differences between the brackets of the left maxillary central incisors between MOR1 and GAC1 groups, and between FOR1 and GAC1 groups. The data of left maxillary canines were statistically significant between MOR3 and GAC3 groups, and between MOR3 and FOR3. Conclusion: At basis of these results, it was possible conclude that despite the same prescription name of different brands, the angulations are different
5

Avaliação das alterações dentárias imediatas à expansão maxilar com o aparelho quadrihélice por meio de tomografia computadorizada de feixe cônico

Floriano, Gilberto January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:35:30Z (GMT). No. of bitstreams: 1 325537.pdf: 2029115 bytes, checksum: dfcdac0cf969ec71a28f21b8f87903e5 (MD5) Previous issue date: 2013 / Objetivo: Avaliar as alterações dentárias imediatas de inclinação, altura e espessura alveolar na região de molares após a expansão maxilar com o aparelho Quadrihélice por meio de Tomografia Computadorizada de Feixe Cônico. Metodologia: A amostra foi composta por 24 pacientes que utilizaram o aparelho Quadrihélice, com uma ativação mensal de 2mm durante 4 meses, totalizando 8mm de expansão, com mais 2 meses de contenção. As imagens de Tomografia computadorizada de Feixe Cônico (TCFC) foram realizadas no início (T1) e após a contenção de dois meses (T2). Os dados foram obtidos através do método padronizado de análise de imagens e manipulados pelo programa Osirix Medical Imaging Software 32-bit. O teste estatístico utilizado para verificar se havia diferenças entre as médias foi o teste "t" para dados pareados. Resultados: Foi observada redução média na espessura óssea alveolar de 0,57mm e perda óssea vertical média de 0,25mm. A inclinação dos molares para vestibular ocorreu, com um aumento médio de 14o. Conclusões: O Quadrihélice mostrou-se eficiente, mas apresentou perdas ósseas que precisam ser consideradas, realçando que se deve controlar a inclinação vestibular dos molares para se obter um melhor resultado.<br> / Abstract : Objective: To evaluate immediate dental tip, height and thickness of alveolar molar region after maxillary expansion appliance with Quad-helix through Cone Beam Computed Tomography. Methods: The sample consisted of 24 patients who used the device Quad-helix activation with a 2mm monthly for 4 months, reaching 8mm expansion, with over two months of contention. Images of beam computed tomography (CBCT) were performed at baseline (T1) and after retention of two months (T2). Data were obtained through standardized method of image analysis and manipulated by the program OsiriX Medical Imaging Software 32 - bit. The statistical test used to check if there were differences between the means was the "t" test for paired data. Results: There was a mean reduction in alveolar bone thickness of 0,57mm and average vertical bone loss of 0,25mm. The inclination of the molars buccally occurred, with an average increase of 14o. Conclusions: the Quad-Helix was efficient, but showed bone loss that must be considered, stressing that it must control the buccal inclination of molars to obtain better result.
6

Avaliação das alterações dentoalveolares e esqueléticas induzidas pelo Ertty System® no tratamento da má oclusão de classe II subdivisão

Meloti, Aparecida Fernanda [UNESP] 18 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-18Bitstream added on 2014-06-13T20:24:52Z : No. of bitstreams: 1 meloti_af_dr_arafo.pdf: 1748222 bytes, checksum: 1ea6d970c95044169f8ff30279c00e26 (MD5) / O Ertty System® é um sistema intrabucal para distalizar os molares superiores. Estudos a respeito desse sistema relatam uma distalização não apenas dos molares, mas de todo o segmento lateral, pré-molares e canino, com um movimento de translação e sem necessidade de muita cooperação do paciente. O presente estudo visou avaliar as alterações dentoalveolares e esqueléticas promovidas pelo tratamento com o Ertty System®. A amostra foi composta por 27 indivíduos brasileiros, de ambos os gêneros, com idades entre 12 e 15 anos, apresentando má oclusão de Classe II subdivisão, que foram tratados ortodonticamente com o Ertty System®. Para avaliação das mudanças dentoalveolares e esqueléticas, foram utilizadas telerradiografias em normas lateral e em 45o, e radiografias submentonianas obtidas em três tempos distintos: inicial (T1); na instalação do Ertty System® ou após o alinhamento e nivelamento com aparelho ortodôntico fixo (T2); e na remoção do Ertty System® (T3). Verificou-se que o Ertty System® distaliza os primeiros molares, os pré-molares e canino em um curto período de tempo (em média, quatro meses). Os segundos molares, mesmo sem estarem envolvidos na mecânica, acompanham esse movimento. Os molares distalizados não ficam inclinados após a distalização, mas, sim, verticalizados. Durante a distalização ocorre, na arcada superior, expansão e giro mesiodistal dos molares superiores e do canino superior; e, na arcada inferior, vestibularização dos incisivos inferiores, mesialização dos primeiros molares inferiores, giro mesiodistal do molar no lado normal e giro mesiodistal do canino no lado normal, além de uma contração desses dentes no lado afetado. Além disso, houve diminuição do overjet, overbite e Wits; um giro horário do plano oclusal e um crescimento e/ou deslocamento mandibular no lado da má oclusão, que precisa ser mais... / Ertty System® is an intraoral system for maxillary molars distalization. Studies on this system report not only distalization of molars, but of the entire lateral segment, canine and premolars, with a translation movement and without demanding great patient’s cooperation. The present study aimed to evaluate dentoalveolar and skeletal changes promoted by treatment with Ertty System®. The sample was composed of 27 Brazilian subjects of both sexes, aged between 12 and 15 years, with Class II subdivision malocclusion who were orthodontically treated with Ertty System®. To evaluate the dentoalveolar and skeletal changes were used lateral, oblique (45o), and submentovertex radiographs, obtained at three different times: baseline (T1); at Ertty System® installation or after alignment and leveling with fixed orthodontic appliance (T2); and at the removal of Ertty System® (T3). It was found that the Ertty System® distalizes first molars, premolars and canine over a short period of time (on average, four months). The second molars, even without being involved in the mechanics, followed this movement. Distalized molars are not inclined after distalization, but in an upright position. During distalization occurs, in the upper arch, expansion and mesiodistal rotation of maxillary molars and maxillary canine, and, in the lower arch, buccal tipping of the mandibular incisors, mesial movement of mandibular first molars, mesiodistal rotation of molar on the normal side and mesiodistal rotation of canine on the normal side, and a contraction of these teeth on the affected side. In addition, there was a decrease of overjet, overbite and Wits, a clockwise rotation of occlusal plane and growth and/or mandibular displacement on the malocclusion side, which needs to be further clarified by future studies. According to the results obtained in this study... (Complete abstract click electronic access below)
7

Análise tridimensional das alterações dento-alveolares em molares superiores após o uso do aparelho de Herbst

Kameyama, Daniela Cristina [UNESP] 24 February 2014 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-24Bitstream added on 2015-01-26T13:30:35Z : No. of bitstreams: 1 000806023_20170224.pdf: 430940 bytes, checksum: 732bc309de3bb8ef840b5ce36172ee96 (MD5) Bitstreams deleted on 2017-02-24T13:00:38Z: 000806023_20170224.pdf,. Added 1 bitstream(s) on 2017-02-24T13:01:26Z : No. of bitstreams: 1 000806023.pdf: 822032 bytes, checksum: d855d06c43058a714524451f73b5756a (MD5) / Este estudo teve como objetivo avaliar tridimensionalmente a altura e espessura óssea alveolar e alterações dentárias no sentido vertical e transversal na maxila após o uso do aparelho de Herbst. A amostra prospectiva foi composta por 23 indivíduos brasileiros, leucodermas, de ambos os gêneros, com idade média de 15.76 ± 1.75 anos, apresentando a má oclusão de Classe II divisão 1, com deficiência mandibular que foram tratados com o aparelho de Herbst por um período de 8 meses. Para essa avaliação foram utilizadas tomografias computadorizadas de feixe cônico (TCFC) obtidas antes (T1) e depois do tratamento (T2) para análise e medição das alterações estruturais: altura e espessura óssea alveolar na região de molares e, alterações dentárias no sentido vertical de molares e transversal (distância e inclinação intermolar). O erro do método foi avaliado pelo Coeficiente de Correlação Intraclasse (ICC) e o teste t pareado foi usado para comparar as medidas obtidas em T1 e T2 com nível de significância de 5%. Os resultados mostraram que o ICC foi elevado para todas as medições (0,95). Houve aumento da altura (0,37mm) e espessura óssea alveolar apenas na lingual da região dos molares superiores sendo que com os terços médio (0,45mm) e apical (0,58mm) tiveram resultados mais significativos. Quanto à relação dentária teve diminuição significativa da angulação intermolar com média de 4,6° (p<0,05). Concluímos que o tratamento ortodôntico com aparelho de Herbst levou a alterações apenas na lingual da altura e espessura óssea alveolar e na angulação intermolar da arcada superior. / This study aimed to evaluate three-dimensionally the height and thickness of alveolar bone and dental changes at vertical and crossectional direction after use of Herbst appliance. The prospective sample was composed of 23 Caucasian Brazilian individuals of both genders, with mean age: 15.76 ± 1.75 years, presenting Class II division 1 malocclusion with mandibular deficiency and treated with Herbst appliance during a period of 8 months. Cone-beam computed tomography images were obtained before (T1) and after treatment (T2) to analyse and measure the structures: height and thickness of alveolar bone at the molar region and dental changes at vertical of the molars and crossectional direction (intermolar distance and inclination). The error of the method evaluated by the Intraclass Correlation Coefficient (ICC) and Paired t-tests were used to compare T1 and T2 with significance level of 5%. The results showed that the ICC was high for all measurements (0.95). There was increase in height (0.37 mm) and alveolar bone thickness only at the lingual region of the upper molars with more significant result at the middle third (0.45 mm) and apical region (0.58 mm). Regarding dental changes, there was a significant decrease at intermolar angulation mean of 4.6° (p<0.05). It was concluded that orthodontic treatment with Herbst appliance led to changes in height and alveolar bone thickness at the lingual and intermolar angulation in the upper arch.
8

Estudo de propriedades físicas de materiais adesivos ortodônticos

Seixas, Michela Melissa Duarte [UNESP] 25 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-25Bitstream added on 2014-06-13T20:50:18Z : No. of bitstreams: 1 seixas_mmd_me_ilha.pdf: 666243 bytes, checksum: 52240f181efba99ad50036dbab585732 (MD5) / O avanço tecnológico trouxe grandes benefícios para a prática odontológica. Na ortodontia fixa, a colagem direta dos acessórios ortodônticos revolucionou a confecção de aparelhos ortodônticos. A introdução do condicionamento ácido do esmalte dental permitiu o desenvolvimento e aperfeiçoamento da fixação direta dos acessórios ortodônticos aos dentes, fazendo da colagem direta um procedimento clínico rotineiro. As resinas compostas passaram a ser largamente utilizadas como material de colagem devido às suas propriedades adesivas, e os bráquetes foram confeccionados de modo a apresentarem retenções mecânicas. Para a utilização de um material adesivo em ortodontia, é fundamental que o agente cimentante promova adesão suficiente entre o acessório ortodôntico e a superfície dentária. Outra característica importante é que o mesmo apresente um coeficiente de expansão térmica próximo ao do dente. O estudo da eficiência dos adesivos é sempre uma motivação e tem auxiliado os profissionais a obterem melhores resultados clínicos. Desta forma, este trabalho teve como objetivo avaliar a resistência ao cisalhamento com e sem termociclagem das resinas compostas Concise Ortodôntico e Fill Magic Ortodôntico, por meio de ensaios mecânicos, assim como estudar as diferenças de dilatação térmica entre os materiais do sistema dente-resina-bráquete, utilizando-se da técnica de extensometria. O Concise Ortodôntico apresentou os melhores resultados de resistência ao cisalhamento com e sem termociclagem e um menor coeficiente de expansão térmica comparados aos respectivos resultados de cisalhamento e expansão térmica da resina Fill Magic Ortodôntico. O material utilizado na confecção do bráquete ortodôntico apresentou um coeficiente de expansão térmica mais próximo ao do esmalte dental. Por outro lado, apresentou coeficiente... . / The technological progress brought great benefits in the practice of dentistry. In the orthodontics, the direct bonding of the orthodontic attachments revolutionized the making of the orthodontic appliances. The introduction of the acid etching technique allowed the development and improvement of the direct fixation of the brackets to the teeth, becoming the direct bonding a routine clinical procedure. The composites are used broadly as bonding material due to their adhesive properties and the brackets present good mechanical retention. The material adhesive to be used has to promote enough adhesion between the bracket and the dental surface. Besides, it is important that it presents a coefficient of thermal expansion similar to the one of the tooth. The study of the efficiency of the adhesives systems is always a motivation and it aids the professionals to obtain better clinical results. Therefore, this work had as objective to evaluate the shear bond strength with and without thermoclycling of the composed Orthodontic Concise and Fill Magic, through mechanical tests, as well as to study the thermal expansion of the materials of the tooth-resin-bracket system by extensometry technique. The Concise resin presented the better results of shear bond strength with and without thermoclycling and a smaller coefficient of thermal expansion when compared to the respective results for Fill Magic resin. The bracket’s material presented a coefficient of thermal expansion similar to the dental enamel. On the other hand, its coefficient is smaller than those of the two evaluated resins (twice smaller than to of Concise and three times to of Fill Magic).
9

AVALIAÇÃO COMPARATIVA DA HIGIENIZAÇÃO BUCAL DE PACIENTES COM APARELHO ORTODÔNTICO FIXO LINGUAL E LABIAL / Comparative avaliation of bucal hygiene in lingual and labial orthodontic patients

Galvão, Maria Christina de Souza 29 March 2006 (has links)
Made available in DSpace on 2016-08-03T16:31:04Z (GMT). No. of bitstreams: 1 Maria Christina.pdf: 1062835 bytes, checksum: 6697fefc437edf793c9a12b9ad8bdc34 (MD5) Previous issue date: 2006-03-29 / The aim of this research was to assess the oral hygiene in adult patients after lingual brackets placement through bleeding on probing and plaque index and to compare with labial orthodontics patient. The group 1 (G1) consisted of 11 lingual orthodontic patients, mean age 22y and 9m. The group 2 (G2) consisted of 19 labial orthodontic patients, mean age 25y 8m. The bleeding on probing and plaque index was checked before bonding (T0), from one to two weeks after total bonding, including wires (T1). After that brushing instructions were given to them. The patients were checked again after 1 month (T2), 2 months (T3), and 3 months (T4), when reinforcement instructions were given. The appliance kind effect was compared between groups and the lingual and labial face changes in the same person were assessed, too. There was a significant worsening in plaque index in T1, except for the lingual orthodontic labial face. Both labial and lingual appliances seemed to cause an increase in gingivitis in adult patients, showed by gingival bleeding. After instructions G2 showed to return to initial plaque index. However, G1, despite some improvement, couldnt do the same, and was less efficient than G2 in T1 and T4. / O objetivo desse trabalho foi avaliar a higiene oral de pacientes adultos, pela análise dos índices de sangramento gengival e de placa pré e pós-colocação do aparelho ortodôntico fixo lingual e compará-la a um grupo de pacientes com aparelho ortodôntico fixo labial. O grupo 1 (G1), foi constituído de 11 pacientes, com idade média de 22 anos e 9 meses, tratado com braquetes linguais. O grupo 2 (G2) foi formado por 19 pacientes, com idade média de 26 anos e 8 meses, tratado com braquetes labiais. O sangramento gengival e o índice de placa foram avaliados antes da colagem (T0); 1 semana/15 dias após a colocação total do aparelho, inclusive com arcos (T1). Após isso, foram dadas instruções de higienização. Os pacientes foram novamente avaliados 1 mês após a colocação (T2); 2 meses (T3) e 3 meses (T4), quando foram dados reforços das instruções conforme necessário. Nas avaliações inter-grupos, foram comparadas as alterações relativas ao tipo de aparelho empregado e nas avaliações intra-grupos comparou-se a face vestibular e lingual de um mesmo indivíduo. Os resultados mostraram que houve um significante aumento no índice de placa em T1, exceto na face vestibular dos pacientes com aparelho lingual. Em ambos os grupos, houve um aumento semelhante da gengivite caracterizada pelo aumento do sangramento gengival. Após as instruções de escovação, os pacientes do G2 foram capazes de retornar aos seus índices de placa anteriores à colocação do aparelho. Os pacientes do G1, apesar de haver melhora, não conseguiram voltar aos índices de placa iniciais e tiveram uma menor eficácia de higienização comparado a G2 em T1 e T4.
10

Estudo comparativo da degradação de forças geradas por elásticos ortodônticos sintéticos e molas de níquel-titânio

Araujo, Fabiana Ballete de Cara [UNESP] 19 May 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-05-19Bitstream added on 2014-06-13T20:01:53Z : No. of bitstreams: 1 araujo_fbc_dr_sjc.pdf: 312103 bytes, checksum: 3f21d0423598e73724ad1f5cf82e2469 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Analisaram-se separada e comparativamente três marcas comerciais de elásticos ortodônticos sintéticos e de molas de NiTi (MORELLI, ORMCO e GAC), quanto à degradação da força sofrida por estes materiais em função do tempo, quando submetidos a simulação das condições bucais. Os elásticos e molas foram inicialmente termociclados (temperaturas de 15°C e 45°C), em seguida estirados em 20mm, imersos em saliva artificial a 37°C e desativados em 0,5mm semanais. As leituras da quantidade de força gerada pelas amostras foram realizadas nos momentos: inicial, 1, 24, 48 horas, 7, 14, 21 e 28 dias. Observou-se significativa redução na quantidade de força gerada pelos elásticos na primeira hora de ativação, que variou de 49,5% a 53%, enquanto que para as molas a degradação foi signicativamente menor, com valores entre 4,2% e 18,1%. Ao término de 28 dias de testes, as amostras de elásticos sofreram redução média na quantidade de força gerada entre 82,7% e 91,2% (GAC-82,7%, ORMCO-86,0% e MORELLI- 91,2%) já as amostras de molas apresentaram degradação média de força entre 17,5% e 32,2% (MORELLI-17,5%, ORMCO-27,3% e GAC-32,2%). Concluiu-se que, em geral, os elásticos promoveram maior índice inicial de força que as molas, mas após as primeiras 24 horas de ativação a quantidade de força gerada pelos elásticos era menor que a promovida pelas molas, que assim apresentaram níveis médios de força mais constantes que os elásticos ao longo dos testes. / Three commercial marks of synthetic elastics and NiTi coil springs (MORELLI, ORMCO, GAC) were separately and comparably analyzed, according to the force degradation generated by these materials, because of the time, when maintained stretched in artificial salivary, 37°C. The synthetic elastics and NiTi coil springs were thermal- cycled (15°C-45°C) and stretched in 20mm, and this stretch was reduced in 0,5mm weekly. The readings of the amount generated for elastics and coil springs were done in the intervals 0, 1, 24, 48h, 7, 14, 21 and 28 days. Where observed significative reduction on the amount of force generated for the elastics in the first hour of the activation (49,5%- 53%), and 82,7% - 91,2% in 28 days of the tests ( MORELLI - 91,2%, ORMCO - 86,0%, GAC - 82,7%);, while the generated force for NiTi coil springs suffered a reduction of 4,2%- 18,1%, in the first hour of the experimentation and 17,5% - 32,2% in 28 days of the stretch (MORELLI - 17,5%, ORMCO - 27,3%, GAC - 32,2%). We conclude that for most elastics delivered larger initial force that NiTi coil springs, but after 24 hours of activation the NiTi coil springs delivered larger force that the elastics and generated level of the force more constant that elastics.

Page generated in 0.0608 seconds