• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1863
  • 23
  • 18
  • 18
  • 16
  • 16
  • 16
  • 10
  • 7
  • 7
  • 7
  • 6
  • 5
  • 4
  • 4
  • Tagged with
  • 1940
  • 1295
  • 1199
  • 806
  • 544
  • 362
  • 351
  • 327
  • 315
  • 248
  • 234
  • 214
  • 198
  • 179
  • 175
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

INVERSÃO SÍSMICA TOMOGRÁFICA USANDO NORMA DE INTEGRAL DE FUNÇÃO

Santos, Vânia Gonçalves de Brito dos 17 December 2012 (has links)
Submitted by Souza Tanajura Augusto (cast@ufba.br) on 2012-12-17T17:17:30Z No. of bitstreams: 1 Brito.pdf: 1639442 bytes, checksum: 04993bb83295b91b69013390b33d4169 (MD5) / Made available in DSpace on 2012-12-17T17:17:30Z (GMT). No. of bitstreams: 1 Brito.pdf: 1639442 bytes, checksum: 04993bb83295b91b69013390b33d4169 (MD5) / Centro de Pesquisa em Geofísica e Geologia da UFBA, com apoio da UEFS, CAPES e PETROBRAS S.A. / O alto consumo de tempo em processamento computacional é um grande problema geralmente associado aos métodos de tomografia de raios sísmicos. Isto ocorre porque, em cada passo do processo iterativo da inversão definida pelo método tomográfico, o problema do "two-point ray-tracing" deve ser resolvido para cada par de fonte-receptor. A fim de resolver este tipo de problema, a norma vetorial, comumente usada nas funções de erro a ser minimizado no processo de inversão, é substituída por uma norma da integral de função, que nos permite estimar parâmetros do modelo através da minimização da área entre as curvas de tempos observados e calculados que são interpoladas (ou ajustadas) aos pontos dos dados. Desenvolvimentos matemáticos e experimentos numéricos relativamente simples, com modelos de campos de velocidade sísmica compressional (polinomialmente parametrizados), mostram que a norma da integral de função nos permite poupar uma enorme quantidade de tempo de processamento sem uma importante perda de precisão. Em alguns casos, os parâmetros do modelo podem ser melhor estimados com a norma de função do que com a norma vetorial, tradicionalmente utilizada na inversão de tomografia sísmica. / Pós Graduação em Geofísica da UFBA
2

Estudo tomográfico do encéfalo de cães dolicocefálicos, mesaticefálicos e branquicefálicos clinicamente sadios

Doiche, Danuta Pulz [UNESP] 01 August 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-01Bitstream added on 2014-06-13T19:09:45Z : No. of bitstreams: 1 doiche_dp_me_botfmvz.pdf: 1123328 bytes, checksum: 8e1dbfd7effb20988189cb5e55ffe74f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A Tomografia Computadorizada (TC), juntamente com a Ressonância Magnética, são modalidades de diagnóstico por imagem avançadas, consideradas de escolha para a avaliação do sistema nervoso, por fornecerem imagens livres de sobreposições e detectarem pequenas diferenças de densidade tecidual. Dentro de qualquer estudo, o conhecimento das possíveis formas de apresentação de cada estrutura e a determinação do limite entre o fisiológico e o alterado são fundamentais para um estudo preciso. O presente trabalho teve como objetivo a descrição dessas variações nas imagens tomográficas do encéfalo, no que diz respeito aos ventrículos laterais e atenuação do parênquima encefálico e cerebelar entre os grupos aqui estipulados (grupo dolicocefálico composto por cães pastores Alemães, grupo mesaticefálico composto por Rottweilers e grupo braquicefálico compostos por cães da raça Boxer) e assim enriquecer a avaliação cerebral à TC e minimizar erros de interpretação. Foram detectadas diversas diferenças individuais e entre os grupos à avaliação qualitativa. Quantitativamente, houve diferença da altura ventricular entre os braquicefálicos e os demais, mostrando que ainda não é possível apenas uma faixa de valores da altura ventricular comum a todos os cães, e que, para as raças braquicefálicas o valor da razão da altura ventricular e encefálica até 25% pode servir como limite superior nos animais hígidos. Os valores de atenuação finais na fase pré-contraste são compatíveis com trabalhos anteriores, o bulbo olfatório e o cerebelo apresentaram-se diferentes estatisticamente em relação aos demais locais. A única raça que teve nas fases simples e contrastada diferenças estatísticas em todos os locais foram os animais do grupo B / Computed tomography (CT) along with Magnetic Ressonance Imaging (MRI) are diagnostic imaging modalities of advanced, considered choice for the evaluation of the nervous system, for providing free images overlap and detect small differences in tissue density. Within any study, knowledge of the possible forms of presentation of each structure and determining the limit between physiological and change are fundamental to a precise study. This study aimed to describe these variations in the tomographic images of the brain, with respect to the lateral ventricles and attenuation of brain parenchyma and cerebellum between the groups set forth herein (dolichocephalic group composed of German shepherd dogs, a group composed of rottweilers and mesaticephalic brachycephalic group consisting of Boxer dogs) and thus enrich the evaluation of brain CT and minimize misunderstandings. We detected several differences between individuals and groups in the qualitative assessment of the aspects mentioned. Quantitatively, there were differences between the ventricular height between brachycephalic and others, showing that it is not possible just a strip of ventricular height values common to all dogs, and that for brachycephalic breeds the value of 25% can serve as upper limit in healthy animals. The final attenuation values in the pre-contrast are consistent with previous works, the olfactory bulb and cerebellum were different statistically when compared to other locations. The only race that was simple and contrasted phases statistical differences in all sites were the animals in group B
3

Teoria e experimentação com metodos incrementais relaxados em tomografia por emissão / Theory and experimentation with relaxed incremental methods in emission tomography

Helou Neto, Elias Salomão 04 December 2005 (has links)
Orientador: Alvaro Rodolfo De Pierro / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Matematica, Estatistica e Computação Cientifica / Made available in DSpace on 2018-08-14T01:15:10Z (GMT). No. of bitstreams: 1 HelouNeto_EliasSalomao_M.pdf: 1733678 bytes, checksum: 44e680915a74638897d279b1d09a007f (MD5) Previous issue date: 2005 / Resumo: O principal assunto desta dissertação é a teoria e prratica em metodos iterativos incrementais relaxados para reconstrução estatística de imagens em Tomografia por Emissão de Positrons - PET. Especial atenção é dedicada ao estudo teorico dos algoritmos, com a apresentação de resultados novos sobre convergência com o parâmetro de relaxação variando dentre as subiterações e sobre a regularidade da sequência gerada por tais algoritmos no caso específico da função de log-verossimilhança que surge em PET. Alem disso, uma comparação experimental entre a qualidade da imagem obtida com metodos relaxados e não relaxados é efetuada / Abstract: The main subject of this dissertation is the theory and practice in iterative incremental relaxed methods for statistical image reconstruction in Positron Emission Tomograpy | PET. Special atention is drawn to the theoretical study of the algorithms, with the presentation of new results concerning convergence with a relaxation parameter wich is allowed to vary within the subiterations and about the regularity of the sequence generated by such algorithms in the specific case of the log-likelihood function that arises in PET. Furthermore, an experimental comparsion is made to test the quality of the image obtained with relaxed methods against those generated by non-relaxed ones / Mestrado / Mestre em Matemática Aplicada
4

Estudo da tomografia por emissão de pósitrons com tomografia computadorizada (PET/CT) com FDG-18F na avaliação de resposta à terapia neoadjuvante com quimiorradioterapia no câncer de reto distal

Anjos, Dalton Alexandre dos 10 June 2016 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Medicina, Programa de Pós-Graduação em Ciências Médicas, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-07-20T16:54:09Z No. of bitstreams: 1 2016_DaltonAlexandredosAnjos.pdf: 20486810 bytes, checksum: a28369d0c9e328cc24bf3ab244e0b7e8 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-08-16T19:41:54Z (GMT) No. of bitstreams: 1 2016_DaltonAlexandredosAnjos.pdf: 20486810 bytes, checksum: a28369d0c9e328cc24bf3ab244e0b7e8 (MD5) / Made available in DSpace on 2016-08-16T19:41:54Z (GMT). No. of bitstreams: 1 2016_DaltonAlexandredosAnjos.pdf: 20486810 bytes, checksum: a28369d0c9e328cc24bf3ab244e0b7e8 (MD5) / Objetivo: A quimorradioterapia (QRT) neoadjuvante seguida de ressecção total do mesorreto é o tratamento padrão para o câncer de reto localmente avançado. A morbidade e mortalidade da intervenção cirúrgica poderiam ser evitadas nos pacientes que atingem a resposta completa. No entanto, se faz necessário um método de diagnóstico confiável, capaz de predizer com acurácia a resposta patológica completa quando a ressecção cirúrgica não é realizada. O objetivo do nosso estudo foi testar se as varáveis quantitativas volumétricas da tomografia por emissão de pósitrons com tomografia computadorizada (PET/CT) antes e depois da QRT são capazes de predizer a resposta completa, correlacionando-as com a resposta patológica e clínica. Métodos: Foram estudados 90 pacientes com câncer retal distal T2-4 N0-2 M0 submetidos a QRT. Estudos de PET/CT foram realizados antes, 6 e 12 semanas após a conclusão da terapia neoadjuvante. A análise quantitativa incluiu os valores de captação padronizada máximo e médio (SUVmax e SUVmed), as variações destes valores após a QRT (ΔSUVmax e ΔSUVmed), o volume tumoral metabólico (MTV), ΔMTV, a glicólise total da lesão (TLG) e ΔTLG usando volumes de interesse com limites predifinidos (20%, 30%, 40% e 50% do SUVmax) e com o melhor ajuste visual (Best visual fit - bvf). Os pacientes foram agrupados como respondedores completos (resposta clínica ou patológica) e incompletos. Os grupos foram comparados entre si quanto aos parâmetros volumétricos de PET/CT. Resultados: Vários parâmetros columétricos de PET/CT se correlacionaram com a resposta completa. A análise das curvas ROC mostrou áreas sob a curva (AUC) maiores para ΔMTV e ΔTLG entre o PET/CT basal e o de 12 semanas. O ΔTLG(bvf) nesse intervalo foi o fator prognóstico com a maior AUC (0,8004; IC95% 0,6881 – 0,9127). Considerando uma queda de TLG(bvf) maior que 92% doze semanas após a QRT, o PET/CT apresentou sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia de 68,4%, 81,4%, 50%, 90,5% e 78,6%, respectivamente. Conclusões: Os parâmetros volumétricos do PET/CT com FDG- 18F são uma ferramenta útil para predizer a resposta à QRT neoadjuvante em pacientes com câncer de reto distal. Dentre os diversos parâmetros volumétricos restados, o ΔTLG(bvf) foi o que apresentou a maior capacidade de predizer a resposta patológica completa. _______________________________________________________________________________________________ ABSTRACT / Purpose: Neoadjuvant chemoradiation therapy (CRT) followed by rectal resection is the standard treatment for locally advanced rectal cancer (LARC). Patients that achieve complete pathological response would potentially avoid the morbidity of rectal resection. However, it is important to rely in diagnostic tests that could effectively predict the complete response when surgical resection is not performed. The aim of our study was to correlate the quantitative volumetric PET/CT variables before and after CRT with the pathologic and clinical response to CRT. Methods: We propectively studied 90 patients with CT2-4N0-2M0 distal rectal cancer submitted to CRT. PET/CT was performed before, 6 weeks and 12 weeks after completion of neoadjuvant therapy. Quantitative analysis include maximum and mean standard uptake values (SUVmax and SUVmean), ΔSUVmax, ΔSUV mean, metabolic tumor volume (MTV), ΔMTV, total lesion glycolysis (TLG) and ΔTLG using VOls (volumes of interest) with predefined thresholds (20%, 30%, 40% e 50%) and variable thresholds (named best visual fit - bvf). Patients were grouped as Complete Responders and Incomplete Responders (clinical or pathological) and were compared among each other in regards to PET/CT volumetric parameters. Results: Several PET/CT volumetric parameters correlates with Complete Response. Receiver operator characteristics (ROC) curve analysis showed higher areas under the curve (AUC) for ΔMTV and ΔTLG between baseline and 12 week PET/CT. ΔTLG(bvf) between baseline and 12 week PET/CT was the prognostic factor with the highest AUC (0,8004; IC95% 0,6881 – 0,9127). For the detection of residual disease and considering a TLG(bvf) decrease of 92% after 12 weeks. PET/CT had a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 68,4%, 81,4%, 50%, 90,5% and 78,6%, respectively. Conclusions: 18F-FDG PET/CT volumetric parameters are a useful tool to predict the response to neoadjuvant CRT in distal rectal cancer patients. Among several volumetric parameters with different thresholds, ΔTLG(bvf) showed the higher AUC to distinguish complete responders from incomplete responders.
5

Estudo tomográfico do encéfalo de cães dolicocefálicos, mesaticefálicos e branquicefálicos clinicamente sadios /

Doiche, Danuta Pulz. January 2011 (has links)
Orientador: Luiz Carlos Vulcano / Banca: Masao Iwasaki / Banca: Rogério Martins Amorim / Resumo: A Tomografia Computadorizada (TC), juntamente com a Ressonância Magnética, são modalidades de diagnóstico por imagem avançadas, consideradas de escolha para a avaliação do sistema nervoso, por fornecerem imagens livres de sobreposições e detectarem pequenas diferenças de densidade tecidual. Dentro de qualquer estudo, o conhecimento das possíveis formas de apresentação de cada estrutura e a determinação do limite entre o fisiológico e o alterado são fundamentais para um estudo preciso. O presente trabalho teve como objetivo a descrição dessas variações nas imagens tomográficas do encéfalo, no que diz respeito aos ventrículos laterais e atenuação do parênquima encefálico e cerebelar entre os grupos aqui estipulados (grupo dolicocefálico composto por cães pastores Alemães, grupo mesaticefálico composto por Rottweilers e grupo braquicefálico compostos por cães da raça Boxer) e assim enriquecer a avaliação cerebral à TC e minimizar erros de interpretação. Foram detectadas diversas diferenças individuais e entre os grupos à avaliação qualitativa. Quantitativamente, houve diferença da altura ventricular entre os braquicefálicos e os demais, mostrando que ainda não é possível apenas uma faixa de valores da altura ventricular comum a todos os cães, e que, para as raças braquicefálicas o valor da razão da altura ventricular e encefálica até 25% pode servir como limite superior nos animais hígidos. Os valores de atenuação finais na fase pré-contraste são compatíveis com trabalhos anteriores, o bulbo olfatório e o cerebelo apresentaram-se diferentes estatisticamente em relação aos demais locais. A única raça que teve nas fases simples e contrastada diferenças estatísticas em todos os locais foram os animais do grupo B / Abstract: Computed tomography (CT) along with Magnetic Ressonance Imaging (MRI) are diagnostic imaging modalities of advanced, considered choice for the evaluation of the nervous system, for providing free images overlap and detect small differences in tissue density. Within any study, knowledge of the possible forms of presentation of each structure and determining the limit between physiological and change are fundamental to a precise study. This study aimed to describe these variations in the tomographic images of the brain, with respect to the lateral ventricles and attenuation of brain parenchyma and cerebellum between the groups set forth herein (dolichocephalic group composed of German shepherd dogs, a group composed of rottweilers and mesaticephalic brachycephalic group consisting of Boxer dogs) and thus enrich the evaluation of brain CT and minimize misunderstandings. We detected several differences between individuals and groups in the qualitative assessment of the aspects mentioned. Quantitatively, there were differences between the ventricular height between brachycephalic and others, showing that it is not possible just a strip of ventricular height values common to all dogs, and that for brachycephalic breeds the value of 25% can serve as upper limit in healthy animals. The final attenuation values in the pre-contrast are consistent with previous works, the olfactory bulb and cerebellum were different statistically when compared to other locations. The only race that was simple and contrasted phases statistical differences in all sites were the animals in group B / Mestre
6

A tomografia computadorizada de alta resolução na avaliação das doenças pulmonares difusas

Pereira, Mônica Corso, 1963- 12 December 1997 (has links)
Orientador: Ilma Aparecida Paschoal / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-07-23T06:58:11Z (GMT). No. of bitstreams: 1 Pereira_MonicaCorso_M.pdf: 5633454 bytes, checksum: e5b17666aaf54f273f1aa1fa2bb48ecf (MD5) Previous issue date: 1997 / Resumo: Existem diversas doenças que produzem uma aparência difusa ao radiograma de tórax. Este trabalho pretendeu avaliar a importância de tomografia de tórax de alta resolução para o diagnóstico destas doenças. Foi feita uma revisão que incluiu: (a) aspectos técnicos da produção de uma TCAR, especialmente nas características que influem na qualidade da imagem produzida; (b)características tomo gráficas da anatomia normal e anormal, enfatizando a disposição das estruturas e alterações no plano transversal e a sua relação com as estruturas do lóbulo pulmonar secundário. Após agrupar 92 exames tomo gráficos de 82 pacientes, encontramos 16 etiologias: Pneumoconiose por alumínio, asbestose, doença crônica por berílio, pneumoconiose por exposição a metal duro, enfisema, doenças das vias aéreas (bronquiolites, bronquectasias e fibrose cística), histiocitose X, histoplasmose, fibrose pulmonar, paracoccidioidomicose pulmonar, pneumonia por Pneumocystis carinii, sarcoidose, silicose, tuberculose. Foi revisada a fisiopatogenia das etiologias abordadas, a fim de a partir do seu entendimento, melhor compreender a origem do sinal tomográfico visualizado. Os achados tomográficos destas doenças foram comparados com aqueles descritos na literatura, e houve concordância na grande maioria. Nos casos de paracoccidioidomicose e histoplasmose, pouco foi recuperado na literatura quanto ao aspecto tomográfico destas "doenças. Nestes casos, a interpretação das alterações foi feita a partir dos dados de fisiopatogenia. Pôde-se constatar que na maioria dos casos a TCAR fornece dados confiáveis quanto à extensão da doença, existência e intensidade de processo inflamatório, distribuição das lesões e melhor local para biópsia, caso esta seja necessária / Abstract: There are many diseases which produce diffuse lung abnormalities and also show uncharacteristic shadows in the thorax radiograph. This work intended to evaluate the importance of high resolution computerised tomography (HRCT) in the diagnosis ofthese diseases. A comprehensive review of literature was performed aiming to discuss: a) technical aspects ofHRCT, specially the ones influencing final image quality; b) HRCT characteristics in normal and abnormal lung anatomy, emphasising the disposition of lung structures and abnormalities at cross sectional plans, and their relationship with the structures of secondary lung lobule. Exarnining 92 HRCT films of 82 patients, 16 aetiologies were determined: aluminium pneumoconiosis, asbestosis, chronic beryllium disease, hard metal pneumopathy, emphysema, airway diseases (bronchiolites, bronchiectasis and cystic fibrosis), histiocytosis X, histoplasmosis, pulmonary fibrosis, paracoccidioidomicosis, Pneumocystis carinii pneumonia, sarcoidosis, silicosis and tuberculosis. Physiopathogenesis of all 16 aetiologies was reviewed aiming to better understanding HRCT patterns seen. HRCT findings in the studie~ cases were then compared with those of the literature, with great matching in the majority of the cases. In the cases of paracoccidioidomicosis and histoplasmosis, poor information' was recovered ITom published works regarding tomographic patterns. In these cases the interpretation of alteration was done through understanding physiopathology. In the majority of the studied cases was possible to conc1ude that HRCT provides reliable data regarding extension of disease, presence and intensity of inflammatory process, distribution of lesions and the better segment for biopsy when needed. / Mestrado / Clinica Medica / Mestre em Clinica Medica
7

Estudo tomográfico e anatômico da órbita e do ducto nasolacrimal de capivaras (Hydrochoerus hydrochaeris - Linnaeus, 1766)

Hirota, Inajara Nakamura January 2017 (has links)
Orientador: Cláudia Valéria Seullner Brandão / Resumo: O estudo objetiva a descrição de valores de referência das medidas cranianas das capivaras, correlacionando a órbita ocular com o ducto nasolacrimal. A documentação destes resultados pode contribuir para padronizar características de normalidade anatômica e favorecer o correto diagnóstico e tratamento de alterações nestas estruturas. As carcaças de capivaras, mantidas por congelamento, foram distribuídas em dois grupos (G) designados GA (n=12) animais adultos (A) e GJ (n=13) para animais jovens (J). Todas foram submetidas ao exame de dacriocistografia por tomografia computadorizada (TC), e às mensurações cranianas. Foram realizadas análises descritivas das mensurações cranianas e do ducto nasolacrimal; e análise estatística da correlação de Pearson com a variável do peso. No GA, não houve correlação entre as medidas do ducto nasolacrimal e as cranianas. No entanto, no GJ, verificou-se correlação com o comprimento facial (r=0,6233), largura facial (r=0,5771), altura craniana (r=0,6981), comprimento craniano (r=0,7116), comprimento total direito (r=0,7517) e esquerdo (r=0,7999). Assim, nos jovens, houve forte correlação com as medidas do comprimento craniano, e no comprimento dos ductos nasolacrimais. No entanto, esse comportamento biológico não foi observado nos animais adultos, demonstrando estabilidade no desenvolvimento. Verificou-se que a órbita ocular em capivara é circular e incompleta; e apresenta o processo zigomático da maxila bem desenvolvido, e o ducto nasolacrimal ... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
8

Avaliação tomográfica do ramo mandibular de indivíduos com diferentes padrões esqueléticos: Contribuição à técnica da osteotomia sagital.

Costa, Paula Bonfim Almeida January 2012 (has links)
Submitted by Programa de Pós-Graduação em Odontologia Saúde (mestrodo@ufba.br) on 2017-04-03T13:35:30Z No. of bitstreams: 1 Monografia Final.pdf: 1259289 bytes, checksum: 4cf1a3deea518034faeb4eb347cf9283 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-06-29T13:42:50Z (GMT) No. of bitstreams: 1 Monografia Final.pdf: 1259289 bytes, checksum: 4cf1a3deea518034faeb4eb347cf9283 (MD5) / Made available in DSpace on 2017-06-29T13:42:50Z (GMT). No. of bitstreams: 1 Monografia Final.pdf: 1259289 bytes, checksum: 4cf1a3deea518034faeb4eb347cf9283 (MD5) / FAPESB / Objetivo: O objetivo deste estudo foi determinar a distância de fusão das corticais látero-mediais do ramo mandibular, superior e posterior à língula, em pacientes com diferentes padrões esqueléticos. Metodologia: Foram utilizadas imagens tomográficas de 120 indivíduos, de ambos os gêneros, na faixa etária entre 18 e 46 anos. A mensuração da distância de fusão das corticais látero-mediais do ramo mandibular foi realizada após a reconstrução tridimensional e multiplanar de um dos lados da mandíbula, utilizando como ponto de referência a junção superior da língula com a face medial do ramo, denominado de ponto “Z”. No corte axial, foi mensurado o término posterior da substância esponjosa, ou seja, a distância de fusão das corticais látero-mediais do ramo mandibular posterior à língula, a partir do ponto Z. E no corte coronal, foi determinado o término superior da substância esponjosa, ou seja, a distância de fusão das corticais látero-mediais do ramo mandibular superior à língula, a partir do ponto Z. A determinação do padrão esquelético no sentido ântero-posterior foi realizada com base na associação dos valores de ANB e WITS, e o padrão esquelético no sentido vertical foi determinado através do ângulo GoGn-SN, ambos mensurados no escanograma dos indivíduos. Resultados: Das 120 imagens tomográficas avaliadas, 60 eram de indivíduos ortognatas, 38 de retrognatas e 22 de prognatas. A média da distância de fusão das corticais látero-mediais do ramo mandibular superior à língula, a partir do ponto Z, foi de 8,23mm, 8,05mm e 5,23mm, no grupo de indivíduos ortognatas, retronatas e prognatas, respectivamente. Em relação à média da distância de fusão das corticais posterior à língula, a partir do ponto Z, foram encontrados os seguintes valores: 10,94mm, 10,39 e 6,29mm, para os ortognatas, retrognatas e prognatas, respectivamente. O teste paramétrico ANOVA revelou que há relação estatisticamente significante entre a distância de fusão das corticais superior e posterior à língula e os diferentes padrões esqueléticos no sentido ântero-posterior (p < 0,001). De acordo com o teste a posteriori de Bonferroni, não houve diferença estatisticamente significante entre os valores encontrados nos padrões ortognata e retrognata. Mas observou-se diferença estatisticamente significante entre os padrões ortognata e prognata, e entre os padrões retrognata e prognata, tanto para a distância de fusão superior, quanto posterior à língula. Em relação ao padrão esquelético no sentido vertical, o teste de correlação de Pearson revelou que há correlação entre o ângulo GoGn-SN e a distância de fusão das corticais superior à língula (r = -0,340; p < 0,01), e também há correlação entre o ângulo GoGn-SN e a distância de fusão posterior à língula (r = -0,318; p < 0,01). Conclusão: A distância de fusão entre as corticais látero-mediais do ramo mandibular superior e posterior à língula é menor nos indivíduos prognatas, quando comparado com os ortognatas e retrognatas, entretanto, não houve diferença estatisticamente significante entre os ortognatas e retrognatas. Há correlação negativa entre o padrão esquelético no sentido vertical (ângulo GoGn-SN) e a distância de fusão das corticais superior e posterior à língula. / Purpose: The purpose of this study was to determine the distance of the point of fusion between lateral and medial cortical plates of the mandibular ramus, above and posterior to the mandibular lingula, in patients with different skeletal patterns. Methodology: It was utilized computed tomography images from 120 individuals of both genders, aged 18 to 46 years. The distance of fusion between lateral and medial cortical plates ramus was measurement after three-dimensional and multiplanar reconstruction of one side of mandibular ramus, using as reference the point top of the lingula with the medial side of mandibular ramus (Point "Z"). In the axial view, was measured the rear end of the cancellous bone, or the distance of fusion between lateral and medial cortical plates ramus, posterior the mandibular lingula, from the point “Z”. In the coronal view, was measured the upper end of the cancellous bone, or the distance of fusion between lateral and medial cortical plates ramus, above the mandibular lingula, from the point “Z”. The determination of anteroposterior skeletal pattern was performed based on the association of values related to ANB and WITS, and the vertical skeletal pattern was based on GoGn-SN angle, both measured in the scout. Results: 60 out of 120 analyzed images were related to individuals with orthognathia, 38 were related to individuals with retrognathia, and 22 related to individuals with prognathism. The average distance of fusion between lateral and medial cortical plates ramus, above the mandibular lingula, from the point “Z”, were 8,23 mm, 8,05 mm and 5,23 mm, in individuals with orthognathia, retrognathia and prognathism, respectively. In relation to the average distance of fusion between lateral and medial cortical plates ramus, posterior the mandibular lingula, from the point “Z”, were 10,94 mm, 10,39 mm and 6,29 mm, in individuals with orthognathia, retrognathia and prognathism, respectively. The parametric test ANOVA revealed that there was a statistically significant relationship between the distance of fusion between lateral and medial cortical plates ramus, above and posterior the mandibular lingula, and the different anteroposterior skeletal patterns (p < 0,001). According to the a posteriori Bonferroni test, there was no statistically significant difference between the values found in individuals with orthognathia and retrognathia. But there was a statistically significant difference between the individuals with orthognathia and prognathism, and between individuals with retrognathia and prognathism, both for the distance of fusion above and posterior the mandibular lingula. Regarding the vertical skeletal pattern, the Pearson correlation test revealed a correlation between the GoGn-SN angle and the distance of fusion between lateral and medial cortical plates ramus above the lingula (r = -0,340; p < 0,01), and correlation between the GoGn-SN angle and the distance of fusion posterior the mandibular lingula (r = -0,318; p < 0,01). Conclusion: The distance of fusion between lateral and medial cortical plates ramus above and posterior the mandibular lingula is smaller in individuals with prognathism compared with individuals with orthognathia and retrognathia, however, there was no statistically significant difference between individuals with orthognathia and retrognathia. There is a negative correlation between the vertical skeletal pattern (GoGn-SN angle) and the distance of fusion of cortical plates ramus above and posterior the mandibular lingula
9

Validade e confiabilidade da caracterização de defeitos ósseos periodontais e peri-implantares por tomografia computadorizada de feixe cônico em diferentes protocolos de aquisição.

Rios, Marcelo de Azevedo January 2014 (has links)
Submitted by ROBERTO PAULO CORREIA DE ARAÚJO (ppgorgsistem@ufba.br) on 2015-07-17T19:59:48Z No. of bitstreams: 1 RIOS, Marcelo de Azevedo.pdf: 2385308 bytes, checksum: 95db292afc362c7f635cbd3bc0c30c73 (MD5) / Made available in DSpace on 2015-07-17T19:59:48Z (GMT). No. of bitstreams: 1 RIOS, Marcelo de Azevedo.pdf: 2385308 bytes, checksum: 95db292afc362c7f635cbd3bc0c30c73 (MD5) / Objetivo: estabelecer a confiabilidade e a validade de medidas realizadas através de tomografias computadorizadas de feixe cônico (TCFC) em defeitos ósseos periodontais e peri-implantares, in vitro, em diferentes protocolos de aquisição, bem como para a classificação de defeitos periodontais e periimplantares. Metodologia: foram confeccionados defeitos de 1, 2 e 3 paredes em mandíbulas humanas com dentes e com dois tipos de implantes (hexágono externo e cone morse). Cada peça anatômica foi tomografada no equipamento KODAK 9000 3D, com variação no voxel (0,0076, 0,2 e 0,4) e na mA (2, 4 e 8 mA) e FOV de 5X3,7 cm. Dois examinadores calibrados foram apresentados aos conceitos de medidas lineares de profundidade, largura, comprimento e altura de defeitos, bem como à classificação quanto ao número de paredes. Em seguida, para cada combinação de voxel e mA, os examinadores realizavam as medidas e classificação, as quais foram repetidas em 3 momentos distintos, com intervalos de 1 semana. Os examinadores podiam fazer modificações de contraste e densidade além de magnificar as imagens para as análise. Os dados obtidos forma tratados estatisticamente no programa R usando o coeficiente de correlação intra-classe buscando a confiabilidade/validade das medidas em termos de concordância, confrontando os valores registrados pelos examinadores com a medida obtida diretamente na peça anatômica com paquímetro digital. Resultados: quanto à validade, para defeitos periodontais, as variações de mA apontaram concordância mediana para altura, alta para comprimento e número de paredes e baixa para largura e profundidade, bem como relação às variações de voxel. Em implantes HE em termo de mA, baixa concordância foi observada para profundidade em qualquer mA e para altura e número de paredes em 8 mA; foi mediana para altura (2 e 4 mA) comprimento (4 e 8 mA) e largura (8mA), sendo as demais concordâncias consideradas altas. Em termos de voxel, foi baixa para profundidade, mediana para altura, comprimento e número de paredes e alta para largura. Em implantes CM em termos de mA, a concordância foi baixa para largura, altura e profundidade (4 e 8 mA) e comprimento (8 mA); mediana para altura (2 mA) e profundidade (2 mA) e alta para comprimento (2 mA) e número de paredes (2 e 4 mA), em termos de voxel, foi baixa para altura e largura, mediana para profundidade e alta para comprimento e número de paredes. A confiabilidade foi alta em praticamente todas as avaliações. Conclusão: variações de voxel não impactaram nos resultados de confiabilidade/validade dos dados seja para defeitos periodontal ou peri-implantares, e que mA menores (2 e 4) foram melhores para avaliações peri-implantares, e não tiveram impacto nas avaliações periodontais. / Purpose: to verify the validity and reliability of linear measurements made with cone beam computed tomography (CBCT) of periodontal and peri-implant infrabony defects, in vitro, with diferent acquisition protocols, as well as to those defects, related to the number of remaining walls surrounding the defects. Metodology: One, two and three walls infra-bony defects were made in dry human mandibles with natural teeth and two kinds of dental implants (external conection and cone morse). Each mandible was scanned on KODAK 9000 3D, with three diferent voxel size (0,076, 0,2 and 0,4) and three diferent mA values (2, 4 and 8 mA), FOV of 5X3,7 cm. Two calibrated examiners were showed to standard concepts about linear meusures as width, heigh, depth and length of defects, as well as to infra-bony remaining wall defect classification. With a week of interval, the examiners performed the image evaluations in different combination of mA and voxel. Statistical analysis were carried out with R software and using the inter-class correlation coeficient (ICC), looking for agreement among both examiners and the real measures from digital calliper (gold standard). Results: validity of mA in periodontal bone deffect evaluation revealed median agreement for heigh, high for length and remaining wall and low for depth and width, the same was observed during voxel evaluation. External conection implants mA validity showed low agreement for depth in all mA and for heigh and remaining wall in 8 mA; median for heigh (2 and 4 mA), length (4 and 8 mA) and width (8mA); the other measurements revaled high agreement. Voxel validity evalution showed low agreement for depth, median for heigh, length and remaining wall and high for width. Cone morse mA validity evaluation shoxed low agreement for width, heigh and depth (4 and 8mA) and length (8mA); median for heigh (2mA) and depth (2 mA) and high por length (2mA) and remaining wall (2 and 4 mA). Voxel evaluation revealed low for heigh and width, median for depth and high for length and remaining wall. Reliability was high for almost all evaluation. Conclusion: voxel variations did not modified validity/reliability results from gold-standard for both periodontal and peri-implant bone deffect evaluations, and 2 and 4 mA revealed an improvement in peri-implant bone deffect evaluation, and did not affected periodontal bone deffect evaluation.
10

Avaliação das alterações imediatas à expansão maxilar rápida e lenta na dentição mista por meio de tomografia computadorizada de Cone-beam

Andriani, Juliana da Silva Pereira January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-26T09:30:45Z (GMT). No. of bitstreams: 1 301872.pdf: 1782929 bytes, checksum: ea850da1c5f5964fcd2d2c0938a300dd (MD5) / Introdução: A deficiência maxilar transversal é comum na dentição mista e sua correção de grande importância para o sucesso do tratamento ortodôntico. A expansão maxilar rápida (EMR) e lenta (EML) têm sido preconizadas como meios de correção da atresia maxilar. O objetivo deste estudo clínico prospectivo é avaliar as alterações sagitais, transversais e verticais imediatas à EMR e EML através de tomografia computadorizada de cone-beam (TCCB) em pacientes em dentição mista. Material e Métodos: Os pacientes selecionados foram aleatoriamente divididos em 2 grupos, sendo que 21 indivíduos (média de 8.43 anos) foram submetidos à EMR e 16 indivíduos (média de 8.7 anos) submetidos à EML. Todos os indivíduos utilizaram disjuntor dento-mucossuportado ativado em 8 mm e realizaram exame de TCCB antes da instalação dos expansores (T1) e após a estabilização (T2). Para a comparação entre os grupos utilizou-se Análise de Variância (ANOVA) two-way com medidas repetidas e teste de Sidak, considerando P<0.05. Resultados: Não houve diferença estatística entre T1 e T2 em ambos os grupos em relação ao SNA, SNB, ANB, SNperp-A, SN-ENA, SNperp.PP, SN.GoGn, Ptx-Ptx e R2. Houve alterações significativas nas distâncias 1-2, 3-4, R1, R1a, R2a, R3a, Área e Ângulo intermolares nos 2 grupos. Somente a EMR apresentou diferença significativa na distância R3 e em Spmd-Spme. A EMR apresentou aumento significativo no ângulo intermolares em relação à EML. Conclusões: Não houve alterações verticais ou sagitais significativas nos 2 grupos. A EMR e EML causam aumento transversal significativo na base maxilar e crista óssea alveolar, porém a EMR causa maior inclinação dentária. A expansão dentoalveolar é maior que a encontrada na base maxilar. A quantidade de expansão varia em torno de 40% da quantidade de abertura do parafuso expansor na região dentoalveolar independente do protocolo de expansão utilizado. / Introduction: Transverse maxillary deficiency is very common in the mixed dentition. This deficiency correction is important to success of orthodontic treatment. The rapid maxillary expansion (RME) and slow maxillary expansion (SME) have been recommended as correction of the maxillary constriction. The aim of this prospective clinical trial is to evaluate the sagittal, transverse and vertical changes immediate to RME and SME using Cone Beam Computed Tomography (CBCT) in patients with mixed dentition. Methods: Selected patients were randomly divided into two groups. Group 1 consisted in 21 individuals (mean age of 8.43 years) submitted to RME. Group 2 consisted in 16 individuals (mean age of 8.7 years) submitted to SME. All subjects used tooth-tissue-borne expander activated in 8 mm and performed CBCT before installation of expanders (T1) and after stabilization (T2). The data were analyzed by two-way repeated analysis of variance (ANOVA) followed by the Sidak test with a significance level of 5%. Results: There were no statistical differences between T1 and T2 in both groups in relation to SNA, SNB, ANB, SNperp-A, SN-ANS, SNperp.PP, SN.GoGn, Ptx-Ptx, and R2. There were significant changes in the distances 1-2, 3-4, R1, R1a, R2a, R3a and Area in both groups. Only RME showed significant differences in the distance R3 and Spmr-Spml. The intermolars angle increased in both groups; however, RME increased to a greater extend than SME. Conclusions: There were no significant differences in sagittal or vertical changes in the two groups. The RME and SME have significant transverse increase at the maxillary base and the alveolar bone crest, but RME causes more dental sloping than SME. Dentoalveolar expansion is greater than maxillary base expansion. The amount of dentoalveolar expansion varies around 40% of the amount of screw opening independent of the expansion protocol used.

Page generated in 0.434 seconds