Ex vivo biomechanical evaluation of a novel screw for tibial plateau leveling osteotomy

Twelve pairs of cadaveric pelvic limbs were harvested from skeletally mature dogs. Tibias were randomly assigned pairwise to two study groups: locking buttress screw fixation (LBS) and bone-screw-fastener fixation (BSF). A tibial plateau leveling osteotomy (TPLO) was performed. Each specimen was positioned in a servohydraulic testing machine to simulate physiological orientation and loading at the mid-point of the stance phase at the walk. Cyclic loading was performed for 30,000 cycles at 4Hz with a peak-load of 1000N. The cyclic test was then continued by stepwise increasing the peak-load at a rate of 75N per 500 cycles until failure of the construct. The findings of this current study suggest that stabilization of the TPLO with BSF in the proximal part of a locking TPLO plate provided similar biomechanical stability under cyclic axial loading conditions as the LBS. BSF may be an acceptable alternative to LBS for TPLO.