Return to search

Cinética de floculação de água bruta com baixa turbidez utilizando sais de alumínio e ferro como coagulante. / Flocculation kinetics of low-turbidity raw water using aluminum and iron salts as coagulants.

Este trabalho teve como propósito investigar a cinética de floculação de água bruta com baixa turbidez, utilizando o sulfato de alumínio (Al2(SO4)3o18H2O) e o cloreto férrico (FeCl3o6H2O) como coagulantes. Os resultados experimentais foram obtidos em ensaios de \"jar test\". A água bruta utilizada nos ensaios foi preparada em laboratório, simulando um manancial superficial eutrofizado contendo células da cianobactéria Microcystis aeruginosa. Foram testadas 5 dosagens distintas de cada coagulante, 3 valores de G, 2 valores de TAS e 12 tempos de floculação. Utilizou-se a turbidez como medida principal de avaliação dos resultados experimentais. O valor de turbidez inicial (N0) foi corrigido, levando-se em consideração o acréscimo de turbidez em função das dosagens de coagulante. Determinou-se que as dosagens mais efetivas, em termos de remoção de turbidez, foram 20 mg.L-1 para o sulfato de alumínio e 40 mg.L-1 para o cloreto férrico (ambas expressas como massa de coagulante). Para ambos os coagulantes, constatou-se que G = 20 s-1 e TAS = 27 m3.m-2.dia-1 resultaram nas melhores eficiências de remoção de turbidez. Verificou-se também a variação do potencial zeta em função das dosagens de coagulante. Observou-se que o aumento da dosagem de coagulante leva à redução do potencial zeta, aproximando-o do ponto isoelétrico. Porém, o ponto isoelétrico não necessariamente coincide com a melhor eficiência em termos de remoção de turbidez. Com base nos resultados experimentais, foi proposta uma modificação ao modelo clássico da cinética de floculação de suspensões coloidais. Nesta, foi incluso um segundo termo referente à ruptura de flocos (quebra irreversível). O ajuste do modelo proposto foi obtido através de procedimentos de iteração numérica computacional com a função \"Solver\" do programa Microsoft Excel®. Foram calculados os valores das constantes KA, KB e KC do modelo proposto. Amostras do lodo gerado nos ensaios de cinética de floculação foram caracterizadas visualmente através de microscopia eletrônica de varredura (MEV). / The purpose of this work was to investigate flocculation kinetics of low-turbidity raw water, using aluminum sulfate (Al2(SO4)3o18H2O) and ferric chloride (FeCl3o6H2O) as coagulants. Experimental results were obtained in jar tests. Raw water used in the jar tests was prepared in laboratory, simulating a eutrophic natural water source containing cells of the cyanobacteria Microcystis aeruginosa. 5 different coagulant doses were tested for each coagulant, 3 G values, 2 SLR values and 12 flocculation times. Turbidity was selected as the major parameter for experimental results analysis. Initial turbidity values (N0) were corrected taking into account turbidity increase due to coagulant dosing. In terms of turbidity removal, it was determined that the most effective dosage for aluminum sulfate was 20 mg.L-1, and for ferric chloride, 40 mg.L-1 (both expressed as coagulant mass). For both coagulants, it was found that G = 20 s-1 and SLR = 27 m3.m-2.day-1 resulted in the best turbidity removal efficiencies. Zeta potential variation, due to coagulant dosing, was also verified. It was noted that increasing coagulant dosing led to zeta potential reduction, bringing it closer to the isoelectric point. However, the isoelectric point does not necessary coincides with the best turbidity removal efficiency. Based on the experimental results, it was proposed a modification to the classic colloidal suspension flocculation kinetics model. In this modification, a second term regarding floc rupture (irreversible breakage) was included. Through computer numeric iteration using Microsoft Excel®\'s \"Solver\" function, the proposed model adjustment was obtained. Kinetics constants KA, KB e KC values, from the proposed model, were calculated. Sludge samples, generated during flocculation kinetics tests, were visually characterized through scanning electronic microscopy (SEM).

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-20072016-143140
Date15 December 2015
CreatorsRodrigo de Oliveira Marques
ContributorsSidney Seckler Ferreira Filho, Carlos Gomes da Nave Mendes, Roque Passos Piveli
PublisherUniversidade de São Paulo, Engenharia Civil, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess