Return to search

Implementação de um instrumento para medição da intensidade de fótons na faixa da mamografia / Implementation of an instrument for measuring the intensity of photons in the mammography range

Submitted by mariana andreazzi (mariana.andreazzi@gmail.com) on 2018-04-17T11:25:04Z
No. of bitstreams: 1
Dissertação M.A.pdf: 1982076 bytes, checksum: ed75a1f8ed32ce6807b4f69ef83cf56b (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-04-18T18:22:44Z (GMT) No. of bitstreams: 1
andreazzi_m_me_ilha.pdf: 4488184 bytes, checksum: 3ae904bc1d08784b0b43e8a989b69419 (MD5) / Made available in DSpace on 2018-04-18T18:22:44Z (GMT). No. of bitstreams: 1
andreazzi_m_me_ilha.pdf: 4488184 bytes, checksum: 3ae904bc1d08784b0b43e8a989b69419 (MD5)
Previous issue date: 2018-02-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Foi implementado um instrumento com a finalidade de medir a intensidade (taxa de fluência de energia) de fótons na faixa de mamografia (22 a 33 kVp) e a tensão do tubo de um mamógrafo. O instrumento é constituído por uma câmara com sensor piroelétrico de metaniobato de chumbo (PbNb2¬O¬¬6) e seu circuito de condicionamento de sinais. Utilizou-se poliácido lático para confeccionar a câmara piroelétrica em uma impressora 3D. O circuito de condicionamento de sinais é um conversor corrente-tensão de alta sensibilidade. A intensidade da radiação foi determinada a partir da taxa de exposição medida com uma câmara de ionização. Uma simulação do espectro de emissão do molibdênio, na faixa de 22 a 33 kVp, foi realizada com o sensor piroelétrico e o software DTSA-II, e comparada com a o feita com um sensor de Si(Li), comumente empregado. Os resultados obtidos mostram que a resposta do instrumento implementado é linear com a tensão do tubo de raios-X e com a intensidade da radiação, e que o espectro de emissão do molibdênio pode ser determinado com o instrumento piroelétrico. / An instrument to measure the intensity (energy fluence rate) of photons in the mammography range (22 to 33 kVp) and the tube voltage of a mammograph. The instrument consists of a chamber with a pyroelectric sensor of lead methaniobate (PbNb2O6) and its signal conditioning circuit. Polyacid was used to make the pyroelectric chamber in a 3D printer. The signal conditioning circuit is a high sensitivity current-voltage converter. The intensity of the radiation was determined from the exposure rate measured with an ionization chamber. A simulation of the emission spectrum for molybdenum, in the range of 22 to 33 kVp, was performed with the pyroelectric sensor and the DTSA-II software, and compared to that simulated using the commonly used Si (Li) sensor. The results show that the response of the implemented instrument is linear with the X-ray tube voltage and the intensity of the radiation, and that the emission spectrum of molybdenum can be determined with a pyroelectric instrument.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/153596
Date07 February 2018
CreatorsAndreazzi, Mariana
ContributorsUniversidade Estadual Paulista (UNESP), Carvalho, Aparecido Augusto de [UNESP], Sanches, Marcelo Augusto Assunção [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.003 seconds