Spelling suggestions: "subject:"dosimetria"" "subject:"dosimetrias""
1 |
Utilização do dosímetro Fricke para dosimetria de máquinas teleterapêuticas, irradiadores gammacel e aparelhos de raios-X superficiaisPEDROSA, Guilherme Andrade Campos January 2006 (has links)
Made available in DSpace on 2014-06-12T23:16:57Z (GMT). No. of bitstreams: 2
arquivo9092_1.pdf: 1354651 bytes, checksum: f2ab2f3a9e819275810bd8831ddf1eec (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2006 / A dosimetria química tem sido utilizada como referência na medida da dose
absorvida, com o dosimetro Fricke, em laboratórios de padronização. Este
dosímetro é considerado um padrão dosimétrico absoluto em medidas de dose de
radiação entre 20 e 400 Gy, cobrindo um amplo espectro de energia, desde raios-
X, raios-g até feixe de elétrons rápidos. O presente trabalho tem como objetivos
implementar o dosímetro Fricke tradicional no Centro Regional de Ciências
Nucleares CRCN/CNEN e desenvolver uma metodologia para a sua utilização
em raios-X de baixa energia, isto é, raios-X com energia média no intervalo de
19,7 KeV a 52,2 KeV. Esta metodologia é requerida para viabilizar uma faixa mais
ampla de aplicação do dosímetro Fricke incluindo os raios-X de baixa energia
utilizados no tratamento de tumores superficiais. O método proposto foi validado
por meio de intercomparaçãoes com câmaras de ionização calibradas para
medidas de Kerma no ar em feixes de radiação de Co-60 e raios-X de baixas
energias (superficiais). Quando utilizado na dosimetria de fontes de radiação gama
de altas energias, Co-60, o desempenho do dosímetro Fricke foi avaliado
comparando-se os seus resultados aos obtidos com câmara de ionização
cilíndricas, rastreadas ao PTB Physikalisch-Technischen Bundesanstalt e ao
NPL National Physical Laboratory. Para análise da reprodutibilidade do
dosímetro Fricke, utilizou-se um irradiador do tipo Gammacell, com 5 amostras de
solução Fricke distribuídas simetricamente; as irradiações foram realizadas em 8
experimentos cujos tempos de irradiação foram de 6,4 até 160 segundos. As
doses induzidas foram analisadas e com a avaliação estatística um desvio padrão
de 1,5 % foi obtido. Para medidas da grandeza dose absorvida na água em feixes
de raios-X, utilizou-se fatores de correção para a resposta do dosímetro Fricke em
relação a uma câmara de ionização de placas paralelas do tipo rastreada ao PTB.
Os resultados indicam que o dosímetro Fricke tradicional opera adequadamente
para dosimetria de altas energias (Co-60) e para se obter uma incerteza em torno
de 3% deve-se utilizar absorvâncias com valores maiores do que 0,15, o que
corresponde a uma dose de aproximadamente 40Gy. Estas condições de
operação do dosimetro Fricke atendem às especificações da norma ASTM E
1026-04. Para a dosimetria de raios-X superficiais, houve a necessidade de
calibrar a resposta do Fricke com a câmara de ionização, pois nesta faixa de
energia o dosímetro Fricke não é absoluto, devendo ser calibrado. A introdução
desta etapa induziu nova incerteza que foi avaliada e calculada na incerteza total.
A incerteza na dosimetria de raios-X superficiais, para doses acima de 62 Gy, com
o dosímetro Fricke é em torno de 10%; neste caso, devido à correção da exatidão
do Fricke em relação à câmara de ionização, uma absorvância de 0,15
corresponde no caso de pior exatidão a uma dose de 62 Gy. A sensibilidade do
método dosimétrico sendo limitada pela medida no espectrofotômetro da
concentração de +3Fe induzida pela radiação, leva à conclusão: o dosímetro Fricke
é um instrumento adequado para a medição de raios-X superficiais em uma faixa
de 42 Gy a 620 Gy
|
2 |
Datação com o método dos traços de fissão : estudo da dosimetria de neutrons com filmes finos de urânio naturalIunes, Pedro Jose 06 June 1990 (has links)
Orientador: Julio Cesar Hadler Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-13T22:17:07Z (GMT). No. of bitstreams: 1
Iunes_PedroJose_M.pdf: 1872468 bytes, checksum: 1d52db3ca9bb19a3ae85a36fadb2de2d (MD5)
Previous issue date: 1990 / Resumo: Neste trabalho, descreve-se sinteticamente a datação com o método dos traços de fissão, MTF, enfocando-se seus dois aspectos mais polêmicos: a falta de um consenso sobre o valor da constante de desintegração por fissão espontânea do 238U, lF, e a inexistência de uma dosimetria de neutrons (medida da fluência de neutrons a que deve ser submetido o mineral a ser datado pelo MTF) que seja aceita sem restrições pelos pesquisadores que utilizam o MTF. A seguir, descreve-se os procedimentos experimentais e os resultados obtidos dentro de um estudo que utilizou filmes finos de urânio natural como dosímetros de neutrons. A partir dos resultados obtidos neste trabalho, pode-se concluir que as características da dosimetria com filmes finos de urânio natural a colocam em uma posição importante em estudos que visem utilizar o MTF como um método independente de outros métodos de datação de minerais / Abstract: Not informed. / Mestrado / Física / Mestre em Física
|
3 |
Datação de obsidianas com o método dos traços de fissãoAraya, Ana Maria Osorio 30 December 1990 (has links)
Orientadores: Julio Cesar Hadler Neto, Giulio Bigazzi / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-13T22:17:54Z (GMT). No. of bitstreams: 1
Araya_AnaMariaOsorio_D.pdf: 1229361 bytes, checksum: 5b8b9c7b766d7e1db708b048a8ca92e9 (MD5)
Previous issue date: 1990 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Física / Doutor em Ciências
|
4 |
Dosimetria de processos de irradiação gama com diodos comerciais de silício / GAMMA RADIATION PROCESSING DOSIMETRY WITH COMMERCIAL SILICON DIODESFerreira, Danilo Cardenuto 07 July 2009 (has links)
Este trabalho contempla o desenvolvimento de dosímetros baseados em diodos de Si para a dosimetria de radiação gama para doses desde 1 Gy até 100 Gy. Este intervalo de dose é freqüentemente utilizada em processos de irradiação de cristais, polímeros conjugados e também em vários estudos biológicos conduzidos no Centro de Tecnologia das Radiações (CTR) do IPEN-CNEN/SP. O dosímetro proposto foi construído a partir do diodo cormecial de Si SFH00206 (Siemens), operando em regime fotovoltaico, cujas características elétricas são adequadas para esta aplicação. As correntes geradas no dispositivo pela radiação gama do 60Co dos irradiadores tipo I e II foram registrada por um eletrômetro digital e armazenadas durante todo o tempo de exposição. Em todas as medidas realizadas verificou-se que os sinais de corrente registrados em função do tempo de exposição eram estáveis. Além disso, a fotocorrente do dispositivo mostrou-se linearmente dependente com a taxa de dose desde 6.1x10-2 Gy/min até 1.9x102 Gy/min. As curvas de calibração dos dosímetros, em termos da carga média registrada em função da dose absorvida, foram obtidas pela integração dos sinais de corrente em função do tempo de exposição. Os resultados evidenciaram uma resposta linear do dosímetro, com um coeficiente de correlação melhor que 0,998 para uma dose total absorvida de até 120 Gy. Finalmente, devido aos pequenos erros experimentais, 5% foi possível medir a dose de trânsito devida ao movimento das fontes radioativas de Cobalto-60 nos irradiadores utilizados neste trabalho. / This work envisages the development of dosimeters based on Si diodes for gamma radiation dosimetry from 1 Gy up to 100 Gy. This dose range is frequently utilized in radiation processing of crystal modifications, polymers crosslinking and biological studies carried out in the Radiation Technology Center at IPEN-CNEN/SP. The dosimeter was constructed by a commercial SFH00206 (Siemens) Si diode, operating in a photovoltaic mode, whose electrical characteristics are suitable for this application. The current generated in the device by the Cobalt-60 gamma radiation from the Irradiators types I and II was registered with a digital electrometer and stored during the exposure time. In all measurements, the current signals of the diode registered as a function of the exposure time were very stable. Furthermore, the device photocurrent was linearly dependent on the dose rate within a range of 6.1x10-2 Gy/min up to 1.9x102 Gy/min. The calibration curves of the dosimeters, e.g., the average charge registered as a function of the absorbed dose were obtained by the integration of the current signals as a function of the exposure time. The results showed a linear response of the dosimeter with a correlation coefficient better than 0.998 for total absorbed dose up to 120 Gy. Finally, due to the small experimental errors 5 % it was also possible to measure the transit dose due to the movement of the Cobalto- 60 radioactive sources in irradiation facilities used in this work.
|
5 |
Dosimetria de processos de irradiação gama com diodos comerciais de silício / GAMMA RADIATION PROCESSING DOSIMETRY WITH COMMERCIAL SILICON DIODESDanilo Cardenuto Ferreira 07 July 2009 (has links)
Este trabalho contempla o desenvolvimento de dosímetros baseados em diodos de Si para a dosimetria de radiação gama para doses desde 1 Gy até 100 Gy. Este intervalo de dose é freqüentemente utilizada em processos de irradiação de cristais, polímeros conjugados e também em vários estudos biológicos conduzidos no Centro de Tecnologia das Radiações (CTR) do IPEN-CNEN/SP. O dosímetro proposto foi construído a partir do diodo cormecial de Si SFH00206 (Siemens), operando em regime fotovoltaico, cujas características elétricas são adequadas para esta aplicação. As correntes geradas no dispositivo pela radiação gama do 60Co dos irradiadores tipo I e II foram registrada por um eletrômetro digital e armazenadas durante todo o tempo de exposição. Em todas as medidas realizadas verificou-se que os sinais de corrente registrados em função do tempo de exposição eram estáveis. Além disso, a fotocorrente do dispositivo mostrou-se linearmente dependente com a taxa de dose desde 6.1x10-2 Gy/min até 1.9x102 Gy/min. As curvas de calibração dos dosímetros, em termos da carga média registrada em função da dose absorvida, foram obtidas pela integração dos sinais de corrente em função do tempo de exposição. Os resultados evidenciaram uma resposta linear do dosímetro, com um coeficiente de correlação melhor que 0,998 para uma dose total absorvida de até 120 Gy. Finalmente, devido aos pequenos erros experimentais, 5% foi possível medir a dose de trânsito devida ao movimento das fontes radioativas de Cobalto-60 nos irradiadores utilizados neste trabalho. / This work envisages the development of dosimeters based on Si diodes for gamma radiation dosimetry from 1 Gy up to 100 Gy. This dose range is frequently utilized in radiation processing of crystal modifications, polymers crosslinking and biological studies carried out in the Radiation Technology Center at IPEN-CNEN/SP. The dosimeter was constructed by a commercial SFH00206 (Siemens) Si diode, operating in a photovoltaic mode, whose electrical characteristics are suitable for this application. The current generated in the device by the Cobalt-60 gamma radiation from the Irradiators types I and II was registered with a digital electrometer and stored during the exposure time. In all measurements, the current signals of the diode registered as a function of the exposure time were very stable. Furthermore, the device photocurrent was linearly dependent on the dose rate within a range of 6.1x10-2 Gy/min up to 1.9x102 Gy/min. The calibration curves of the dosimeters, e.g., the average charge registered as a function of the absorbed dose were obtained by the integration of the current signals as a function of the exposure time. The results showed a linear response of the dosimeter with a correlation coefficient better than 0.998 for total absorbed dose up to 120 Gy. Finally, due to the small experimental errors 5 % it was also possible to measure the transit dose due to the movement of the Cobalto- 60 radioactive sources in irradiation facilities used in this work.
|
6 |
Estimativa da Dose No Paciente e Na Equipe Médica Em Procedimentos Intervencionistas de NeurorradiologiaLUNELLI, Neuri Antonio 17 September 2012 (has links)
Submitted by Eduarda Figueiredo (eduarda.ffigueiredo@ufpe.br) on 2015-03-13T14:35:03Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Tese Final Neuri.pdf: 3852657 bytes, checksum: 1d0afbac9f771c3ec2bdcf7c027993e0 (MD5) / Made available in DSpace on 2015-03-13T14:35:03Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Tese Final Neuri.pdf: 3852657 bytes, checksum: 1d0afbac9f771c3ec2bdcf7c027993e0 (MD5)
Previous issue date: 2012-09-17 / FACEPE / Imagens médicas utilizando radiações ionizantes permitem o diagnóstico e o tratamento em procedimentos intervencionistas de neurorradiologia, que são uma alternativa à intervenção cirúrgica. Entretanto, apesar dos seus benefícios, estes procedimentos geralmente expõem o pacientes e a equipe médica a altas doses de radiação. Este trabalho tem por objetivo a o estudo dosimétrico em médicos e pacientes que se submeteram a angiografias e embolizações cerebrais, em um grande hospital de referência de Recife, Pernambuco. Neste estudo, foram avaliados 228 pacientes adultos e 15 pacientes pediátricos. Os procedimentos foram realizados em um angiógrafo Siemens Artis Zee dotado de um receptor de imagens do tipo detector plano. A dosimetria de pacientes foi realizada utilizando filmes radiocrômicos, dosímetros termoluminescentes e através do registro de parâmetros apresentados pelo equipamento angiográfico. Para a dosimetria ocupacional foram utilizados dosímetros termoluminescentes posicionados nos pés, mãos, região dos olhos, tireoide e tórax dos profissionais. Durante os procedimentos clínicos, foram registrados os parâmetros de irradiação, número de imagens, tempo de exposição, valor do kerma no ar de referência (Ka,r) e do produto kerma no ar-área (PKA). Os resultados obtidos com os filmes radiocrômicos mostraram que, em quatro pacientes, os valores de kerma no ar ultrapassaram o limiar para efeitos determinísticos na pele, sendo que o maior valor medido foi de 8030 mGy. Os maiores valores de doses absorvidas na região dos olhos dos pacientes foram relativamente próximos ao limiar para a ocorrência de catarata. Com relação aos médicos, os resultados mostraram que, em procedimentos realizados com pacientes adultos, a dose efetiva média em angiografias foi de 2,6 μSv e em embolizações cerebrais foi de 4,2 μSv. Os maiores valores de dose efetiva registrados foram de 16 μSv para angiografias e 18,5 μSv para embolizações cerebrais. Os maiores valores de dose equivalente por procedimento, medidos no corpo dos médicos, foram: 557 μSv nos pés, 577 μSv nas mãos e 344 μSv nos olhos, em procedimentos com pacientes adultos. A ausência de acessórios de radioproteção como a cortina e protetor de acrílico plumbíferos, bem como a falta do uso rotineiro de óculos de proteção são explicações para os altos valores registrados. Dependendo do número de procedimentos, as doses recebidas pelos médicos podem exceder os limites de dose anual (20 mSv para o cristalino dos olhos e 500 mSv para extremidades) estabelecidos por normas nacionais e internacionais.
|
7 |
Confecção de dosímetros termoluminescentes de fluoreto de lítio sinterizadoBorges, Volnei January 1983 (has links)
Visando obter, no Brasil, dosimetros de estado sólido, que fossem sensíveis, reprodutíveis, de fácil manuseio e que pudessem ser empregados na dosimetria pessoal, foi desenvolvida uma técnica para obtenção deste dosímetros, utilizando pó de liFdopado com MG e Na. Diversos lotes de pastilhas compactadas a fio e sinterizadas foram investigadas em função da concentração de dopantes e tempo de sinterização. Determinou-se algumas características termoluminescentes, que foram comparadas com as dos dosímetros TLD-100 usados como referência internacional. A metodologia experimental e os resultados com as respectivas análises, são expostos neste trabalho.
|
8 |
Confecção de dosímetros termoluminescentes de fluoreto de lítio sinterizadoBorges, Volnei January 1983 (has links)
Visando obter, no Brasil, dosimetros de estado sólido, que fossem sensíveis, reprodutíveis, de fácil manuseio e que pudessem ser empregados na dosimetria pessoal, foi desenvolvida uma técnica para obtenção deste dosímetros, utilizando pó de liFdopado com MG e Na. Diversos lotes de pastilhas compactadas a fio e sinterizadas foram investigadas em função da concentração de dopantes e tempo de sinterização. Determinou-se algumas características termoluminescentes, que foram comparadas com as dos dosímetros TLD-100 usados como referência internacional. A metodologia experimental e os resultados com as respectivas análises, são expostos neste trabalho.
|
9 |
Correção de artefatos laterais em algoritmo para escâner de mesa para avaliação de filmes radiocrômicos / Correction of side artifacts in algorithm for table scanner for evaluation of radiocromic filmsSantos, Gilvan Lopes dos 05 August 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade UnB Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-11-14T16:04:03Z
No. of bitstreams: 1
2017_GilvanLopesdosSantos.pdf: 4735272 bytes, checksum: 5c463f97448846a35c6b5db7f9c8b2d1 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-11-20T21:30:55Z (GMT) No. of bitstreams: 1
2017_GilvanLopesdosSantos.pdf: 4735272 bytes, checksum: 5c463f97448846a35c6b5db7f9c8b2d1 (MD5) / Made available in DSpace on 2017-11-20T21:30:55Z (GMT). No. of bitstreams: 1
2017_GilvanLopesdosSantos.pdf: 4735272 bytes, checksum: 5c463f97448846a35c6b5db7f9c8b2d1 (MD5)
Previous issue date: 2017-11-20 / Filmes radiocrômicos são indicados para avaliar a diferença entre a dose planejada e a dose depositada em radioterapia. A precisão da dosimetria com o uso de filmes faz com que haja uma relação entre os níveis R, G e B (Red - vermelha, Green – verde, Blue - azul) e as doses de radiação, mas esta relação varia com a posição do filme ao longo do escâner. Para corrigir este problema, este estudo teve por objetivo implementar um algoritmo em código livre, por meio da metodologia proposta por Lewis e Chan (2015). Para isso, foi necessário levantar, por um processo empírico, a relação entre os níveis R, G e B e as doses. Após o levantamento das funções de mapeamento entre os níveis e as doses, uma imagem digitalizada pôde ser convertida em imagem de dose. Assim, os filmes foram preparados, irradiados e escaneados a posições determinadas com intervalos de tempo. As imagens escaneadas foram separadas aos níveis de R, G e B e analisadas com o software ImageJ. Os valores dos níveís de doses foram usados na implementação de códigos do algoritmo contemplando os canais e as posições do filme. Os níveis de R, G e B foram corrigidos nas imagens originais pelo algoritmo usando interpolação linear para gerar nova imagem processada para cada posição em função dos níveis do centro do escâner. O algoritmo foi validado e aprovado com a correção de todas as regiões de artefatos de filmes. Um caso pertinente está na média das duas posições extremas do canal vermelho, em que o desvio da imagem original foi de 5,8%, enquanto o desvio da imagem processada foi de 1,6%. Foi crescente a influência dos efeitos de tempo entre a irradiação e a digitalização dos filmes com desvio de 1% para o período de 12 para 72 horas. O algoritmo corrigiu de modo equivalente as imagens processadas mesmo levando em consideração apenas a posição no processo de correção. As diferenças entre os níveis de R, G e B e as densidades óticas das imagens originais e processadas foram semelhantes. Com este estudo, espera-se ampliar a aplicação do uso do algoritmo para os campos de tratamento de radioterapia. / Radiochromic films are indicated to evaluate the difference between the planned dose and the dose deposited in radiotherapy. The accuracy of the dosimetry with the use of films causes a relationship between the R, G, and B levels and the radiation doses, but this relation varies with the position of the film along the scanner. To correct this problem, this study aimed to implement a free code algorithm in Python, using the methodology proposed by Lewis and Chan (2015). For this, it was necessary to raise by an empirical process, the relationship between the levels R, G, and B (red, green and blue) and doses. After surveying mapping functions between levels and doses, a scanned image could be converted into a dose image. Thus, the films were prepared, irradiated and scanned at determined positions at time intervals. Scanned images were separated at R, G, and B levels and analyzed with ImageJ. The values of dose levels were used in the implementation of algorithm codes contemplating the channels and the positions of the film. The levels of R, G, and B were corrected in the original images by the algorithm using linear interpolation, to generate new processed image for each position as a function of the levels of the center of the scanner. The algorithm was validated and approved with the correction of all regions of movie artifacts. An example is the average of the two extreme positions of the red channel, which the deviation of the original image was 5.8%, while the deviation of the processed image was 1.6%. The influence of the time effects between the irradiation and the scanning of films with 1% deviation for the period from 12 to 72 hours was increasing. The algorithm equivalently corrected the processed images even taking into account only the position in the correction process. The differences between the levels of R, G, and B and the optical densities of the original and processed images were similar. With this study, it is hoped to extend the application of the algorithm to all radiotherapy treatment sites.
|
10 |
Confecção de dosímetros termoluminescentes de fluoreto de lítio sinterizadoBorges, Volnei January 1983 (has links)
Visando obter, no Brasil, dosimetros de estado sólido, que fossem sensíveis, reprodutíveis, de fácil manuseio e que pudessem ser empregados na dosimetria pessoal, foi desenvolvida uma técnica para obtenção deste dosímetros, utilizando pó de liFdopado com MG e Na. Diversos lotes de pastilhas compactadas a fio e sinterizadas foram investigadas em função da concentração de dopantes e tempo de sinterização. Determinou-se algumas características termoluminescentes, que foram comparadas com as dos dosímetros TLD-100 usados como referência internacional. A metodologia experimental e os resultados com as respectivas análises, são expostos neste trabalho.
|
Page generated in 0.0587 seconds