Efeitos de baixas doses de radiação sobre a genese e evolução do tecido de granulação : analises quantitativa e qualitativaWatanabe, Plauto Christopher Aranha 28 August 1993 (has links)
Orientadores: Mario Roberto Vizioli , Frab Norberto Boscolo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-18T04:42:21Z (GMT). No. of bitstreams: 1
Watanabe_PlautoChristopherAranha_M.pdf: 3460697 bytes, checksum: cfe6f6dfd29c279b6536a23622d846ab (MD5)
Previous issue date: 1992 / Resumo: O presente trabalho teve por finalidade pesquisar a genese e evolução do tecido de granulação induzido experimentalmente em ratos, sob a ação local de baixas doses de radiação X, comparando-se os possíveis efeitos produzidos quando da aplicação em dose única e em dose dividida, com o tecido de granulação normal¿Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital / Abstract: The purpose of this search was to study histological and histoquimical aspects of the genesis and evolution of artifficially induced granulation tissue under the effect of low doses X-irradiation. By the other hand, it was also compared the effects produced by X-irradiation applied in simple and divided doses with the untreated granulation tissue aspects ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Radiologia / Mestre em Odontologia
|
42 |
Estados de impureza em poços quânticos de GaAs-Ga1-xAlxAs / Experimental determination of radiation dose distribution in an heterogeneous medium, irradiated with clinical beams of x and gamma rays.Maialle, Marcelo Zoega 02 June 1989 (has links)
Com o objetivo de contribuir para o entendimento de recentes resultados experimentais relativos à transições óticas entre estados eletrônicos Localizados, observados em estruturas de múltiplos poços quânticos , realizamos um estudo teórico investigando os níveis de energias de um elétron ligado a uma impureza hidrogenóide num poço quântico simples. Utilizando a equação de massa efetiva calculamos através do método variacional as energias de um elétron Ligado a uma impureza doadora em um poço quântico de barreiras de potencial finitas . Neste cálculo a blindagem eletrônica do potencial da impureza é tratada no formalismo RPR, podendo tanto o elétron Ligado quanto os elétrons livres ocuparem as duas primeiras subbandas do sistema. Representamos nossos resultados para poços quânticos de GaAs-Ga1-xAlxAs variando a densidade eletrônica e a posição da impureza. Também a densidade de estados de impureza é calculada, uma vez que não restringimos a posição da impureza no poço. O efeito da não-parabolicidade da banda de condução do GaAs e a presença do campo magnético são levados em conta para melhor interpretação dos dados experimentais, que em geral estão em boa concordância com nossos resultados. / The mass-effective equation is used in order to calculate the intra and inter-subband transition energies in the Quantum Wett structures. The electronic screening of the shallow donor impurity is inclued in the RPR method and the energies are found through variational formalism. The binding energies are calcutated as function of the electronic density and impurity position inside the welt. We have calculated the density of states due to impurity position and also the non-parabolicity effect of the GaAs conduction band is analised. For better fitting between our results and the experimental data, we have inclued the magnetic field in the system. Our results seem in a good agreement to those experimentally obtained.
|
43 |
Determinação experimental da distribuição de dose de radiação em meio heterôgenio, irradiado por raios-x e gama radioterápicos / Experimental determination of radiation dose distribution in an heterogeneous medium, irradiated with clinical beams of x and gamma raysRocha, Jose Renato Oliveira 24 April 1989 (has links)
O estudo da distribuição de dose de radiação na região de separação entre dois meios de composições químicas diferentes, irradiados por feixes de fótons de alta energia empregados em radioterapia, tem sido restrito a situação em que o feixe de fótons incide perpendicularmente a superfície plana que separa os dois meios. Este trabalho apresenta um estudo bidimensional da distribuição de dose em um meio heterogêneo formado por água e alumínio, que simulam a interface entre tecido muscular e osso, irradiado por feixes de fótons de energias de 1,25 MeV e 10 MeV. A técnica de medida consiste em irradiar filmes radiográficos posicionados paralelamente a direção dos feixes, passando entre as bases de dois cilindros iguais de alumínio, com os eixos coincidentes, de raio menor que a largura do feixe. A distribuição de dose absorvida nos dois meios, no plano do filme, é medida em função da densidade btica apresentada pelos filmes, explorados por um microdensitômetro. Com isso pretendemos explorar a propriedade do filme de medir a dose de radiação com uma resolução espacial dificilmente igualada por outro tipo de dosímetro. Os resultados obtidos revelaram a existência de regiões onde ocorrem diferenças grandes entre a dose medida e a dose calculada sem considerar a heterogeneidade, coro é feito normalmente no cálculo de doses prescritas nos tratamentos. A comparação dos resultados obtidos no feixe de 1,25 MeV com os resultados de outros autores mostrou-se satisfatória, indicando que a técnica de medida, pouco utilizada nesse tipo de estudo, é bastante viável, principalmente se as informações contidas nos filmes forem totalmente processadas por um programa de computador desenvolvido para essa finalidade. / An experimental study of the perturbation caused by a cylindrical inhomogeneity of aluminium on dose distribution in a water phantom, irradiated by high energy photons used in radiation therapy, was performed, employing radiographic film as dosimeter. With these materials we intended to simulate the interface between bone and muscular tissue. The film was placed parallel to the beam axis, passing between the bases of two aluminium rods, with their axis being perpendicular to the film plane. This system was immersed in a cubic water phantom and irradiated by two photon beams: a gamma ray beam of a cobalt 60 source, and a 10 MeV bremsstrahlung X-ray, both produced by radiation therapy machines. By scanning the films in a computer controlled microdensitometer, the dose distributions were measured in the plane of the films. A previous study of the film response, showed that the optical density is proporcional to dose and film sensitivity is nearly the same in water and aluminium, under charged particle equilibrium condition. It was found that large errors occur when the inhomogeneity is ignored in dose calculation. A dose enhancement of about 9% and 11% in aluminium was observed, respectively, for the gamma and X rays beams. It was concluded that the film is good for this kind of measurements and may be employed in high energy photon beams, in particular, when high spatial resolution is needed. The method may be improved by the development of a software to fully exploit the microdensitometer-computer interface capability.
|
44 |
Estados de impureza em poços quânticos de GaAs-Ga1-xAlxAs / Experimental determination of radiation dose distribution in an heterogeneous medium, irradiated with clinical beams of x and gamma rays.Marcelo Zoega Maialle 02 June 1989 (has links)
Com o objetivo de contribuir para o entendimento de recentes resultados experimentais relativos à transições óticas entre estados eletrônicos Localizados, observados em estruturas de múltiplos poços quânticos , realizamos um estudo teórico investigando os níveis de energias de um elétron ligado a uma impureza hidrogenóide num poço quântico simples. Utilizando a equação de massa efetiva calculamos através do método variacional as energias de um elétron Ligado a uma impureza doadora em um poço quântico de barreiras de potencial finitas . Neste cálculo a blindagem eletrônica do potencial da impureza é tratada no formalismo RPR, podendo tanto o elétron Ligado quanto os elétrons livres ocuparem as duas primeiras subbandas do sistema. Representamos nossos resultados para poços quânticos de GaAs-Ga1-xAlxAs variando a densidade eletrônica e a posição da impureza. Também a densidade de estados de impureza é calculada, uma vez que não restringimos a posição da impureza no poço. O efeito da não-parabolicidade da banda de condução do GaAs e a presença do campo magnético são levados em conta para melhor interpretação dos dados experimentais, que em geral estão em boa concordância com nossos resultados. / The mass-effective equation is used in order to calculate the intra and inter-subband transition energies in the Quantum Wett structures. The electronic screening of the shallow donor impurity is inclued in the RPR method and the energies are found through variational formalism. The binding energies are calcutated as function of the electronic density and impurity position inside the welt. We have calculated the density of states due to impurity position and also the non-parabolicity effect of the GaAs conduction band is analised. For better fitting between our results and the experimental data, we have inclued the magnetic field in the system. Our results seem in a good agreement to those experimentally obtained.
|
45 |
Determinação experimental da distribuição de dose de radiação em meio heterôgenio, irradiado por raios-x e gama radioterápicos / Experimental determination of radiation dose distribution in an heterogeneous medium, irradiated with clinical beams of x and gamma raysJose Renato Oliveira Rocha 24 April 1989 (has links)
O estudo da distribuição de dose de radiação na região de separação entre dois meios de composições químicas diferentes, irradiados por feixes de fótons de alta energia empregados em radioterapia, tem sido restrito a situação em que o feixe de fótons incide perpendicularmente a superfície plana que separa os dois meios. Este trabalho apresenta um estudo bidimensional da distribuição de dose em um meio heterogêneo formado por água e alumínio, que simulam a interface entre tecido muscular e osso, irradiado por feixes de fótons de energias de 1,25 MeV e 10 MeV. A técnica de medida consiste em irradiar filmes radiográficos posicionados paralelamente a direção dos feixes, passando entre as bases de dois cilindros iguais de alumínio, com os eixos coincidentes, de raio menor que a largura do feixe. A distribuição de dose absorvida nos dois meios, no plano do filme, é medida em função da densidade btica apresentada pelos filmes, explorados por um microdensitômetro. Com isso pretendemos explorar a propriedade do filme de medir a dose de radiação com uma resolução espacial dificilmente igualada por outro tipo de dosímetro. Os resultados obtidos revelaram a existência de regiões onde ocorrem diferenças grandes entre a dose medida e a dose calculada sem considerar a heterogeneidade, coro é feito normalmente no cálculo de doses prescritas nos tratamentos. A comparação dos resultados obtidos no feixe de 1,25 MeV com os resultados de outros autores mostrou-se satisfatória, indicando que a técnica de medida, pouco utilizada nesse tipo de estudo, é bastante viável, principalmente se as informações contidas nos filmes forem totalmente processadas por um programa de computador desenvolvido para essa finalidade. / An experimental study of the perturbation caused by a cylindrical inhomogeneity of aluminium on dose distribution in a water phantom, irradiated by high energy photons used in radiation therapy, was performed, employing radiographic film as dosimeter. With these materials we intended to simulate the interface between bone and muscular tissue. The film was placed parallel to the beam axis, passing between the bases of two aluminium rods, with their axis being perpendicular to the film plane. This system was immersed in a cubic water phantom and irradiated by two photon beams: a gamma ray beam of a cobalt 60 source, and a 10 MeV bremsstrahlung X-ray, both produced by radiation therapy machines. By scanning the films in a computer controlled microdensitometer, the dose distributions were measured in the plane of the films. A previous study of the film response, showed that the optical density is proporcional to dose and film sensitivity is nearly the same in water and aluminium, under charged particle equilibrium condition. It was found that large errors occur when the inhomogeneity is ignored in dose calculation. A dose enhancement of about 9% and 11% in aluminium was observed, respectively, for the gamma and X rays beams. It was concluded that the film is good for this kind of measurements and may be employed in high energy photon beams, in particular, when high spatial resolution is needed. The method may be improved by the development of a software to fully exploit the microdensitometer-computer interface capability.
|
46 |
Dosimetria tridimensional por imagens de ressonância magnética com gel MAGIC modificado / Tri-dimentional dosimetry by Magnetic Resonance Imaging using a modified MAGIC gel dosimeterPavoni, Juliana Fernandes 15 May 2009 (has links)
Os avanços nas técnicas de tratamento com radiação ionizante estão gerando distribuições de dose muito complexas que precisam ser verificadas antes da aplicação do tratamento no paciente. Diversos dosímetros já foram propostos para esta verificação, mas o que vem apresentando os melhores resultados são os géis poliméricos que permitem a visualização tridimensional da dose. Neste trabalho desenvolvemos um gel dosimétrico do tipo MAGIC com componentes nacionais, para baratear o custo e assim, facilitar a sua aplicação na rotina clínica. Nós adicionamos formaldeído ao gel para aumentar seu ponto de fusão e facilitar seu manuseio em temperatura ambiente. A avaliação das doses foi feita através da relaxometria em imagens de ressonância magnética nuclear (IRMN). Foi encontrada uma resposta linear para dose de até 15Gy e uma dependência energética significativa para feixes de baixa energia (kVp), enquanto que para alta energia (MV) a dependência encontrada foi pequena. A variação da resposta do dosímetro em função da taxa de dose da irradiação foi menor que 5% nas taxas de 100 a 600cGy/min. A adição de formaldeído não eliminou a dependência da resposta do dosímetro para variações na temperatura durante a aquisição das IRMN, já a integridade da distribuição de dose se manteve inalterada por um período de três meses na irradiação de um campo blindado ao meio. Medidas tridimensionais de distribuição de dose foram realizadas para dois planos de radioterapia com intensidade modulada de feixe o primeiro em um acelerador linear e o segundo em um equipamento de tomoterapia, grande semelhança entre a sobreposição das isodoses e dos perfis de dose das imagens medidas com o gel e esperadas pelo sistema de planejamento (TPS) foi encontrada. A avaliação realmente tridimensional foi feita com os histogramas dose-volume (DVH), sendo que uma sobreposição entre os DVHs calculados para o volume planejado e os esperados pelo TPS foi encontrada nos dois planejamentos. Por tudo o que foi estudado, pode-se concluir que a modificação realizada no gel MAGIC resultou em um dosímetro de fácil manuseio que pode ser aplicado para medidas tridimensionais. / Advances in the treatment techniques with ionizing radiation are resulting in complex dose distributions that need to be verified before the application of the treatment in the patient. Several dosimeters have been suggested for this application, but polymeric gel dosimeters are presenting the best results so far, since they allow three dimensional dose visualization, are tissue equivalent, don\'t have dependence with angular distribution of the incident radiation and have a high spatial resolution. In this work a polymeric gel dosimeter with national components, to reduce de costs and facilitate its introduction in the clinical practice was developed. Formaldehyde was added to the gel formulation to increase its melting temperature and facilitate its use in typical room temperatures found in our country. Dose response analysis was done using nuclear magnetic resonance relaxometry. All the dosimetric characterization was done. We found a linear dose-response curve for doses until 15Gy and significant energy dependence for low energy beams (kVp), but for high energy beams (MV) this dependence is smaller. The response variation when varying the dose rate of irradiation was smaller than 5% in the dose rate range of clinical use in teletherapy (100-600cGy/min). The addition of formaldehyde did not eliminate the dosimeter dependence with variation of the scanning temperature; the integrity of dose distribution was unaltered at least for a tree month period of time in a half beam irradiation phantom. Tri-dimensional dose distributions were measured in two radiotherapy systems using intensity modulated beams, the first one in a linear accelerator and the second in a tomotherapy machine. A high similarity was found between the overlapping of isodoses and dose profiles of the dose distribution measured with the gel and expected by the treatment planning. The real tri- dimensional analysis was done with dose-volume histograms (DVH) and the DVHs measured for the planning volume and expected by the treatment planning were in good agreement. Our results show that the modification done in the gel formulation resulted in a dosimeter easy to handle and feasible for tri-dimensional measurements.
|
47 |
Alternativas para optimização da ação fotodinâmica no tratamento de câncer superficial / Alternatives for optimization of photodynamic action in superficial cancer treatmentSilva, Dilleys Ferreira da 28 November 2014 (has links)
O estudo da distribuição e propagação a luz em tecidos biológicos é importante para diversas aplicações em fototerapias e diagnóstico. Os tecidos biológicos são considerados meios túrbidos, onde existe uma combinação de absorção e espalhamento, e a determinação do comportamento da luz dentro deles tem sido estudado através da aplicação de modelos que tem suas limitações. Então, determinar e manipular a distribuição para entrega da melhor dose de luz é crucial para o sucesso dos tratamentos. Para casos de Terapia Fotodinâmica, em particular, os tratamentos de lesões planas lisas, em grande parte dos casos, são bem sucedidos. Este sucesso deve-se ao fato de que existe uma boa possibilidade de distribuição uniforme da luz dentro do tecido da lesão tratada. Por outro lado, para tumores espessos de superfícies irregulares, a iluminação é dificultada devido à presença de sombras, rachaduras entre outras imperfeições sobre a lesão. Deste modo, a entrega da dose de luz inadequada e a iluminação não homogênea, resultam em regiões de necroses parciais e recidiva. Portanto, é decisivo melhorar o perfil da distribuição dentro do tecido. Neste trabalho avaliamos o acoplamento da luz utilizando um gel posicionado entre a fonte ( λ= 630 nm) e a superfície de um phantom sólido. O acoplamento do feixe foi melhorado incorporando baixas concentrações de espalhadores ao gel. Imagens do perfil de distribuição da luz foram coletadas e transformadas em matrizes de intensidades, e posteriores curvas de isointensidades. Nossos resultados mostraram uma grande melhora na uniformidade da distribuição. De fato, utilizando um meio acoplador, conseguimos entregar um feixe mais homogêneo promovendo uma melhor iluminação. Esta técnica elimina drásticamente os efeitos da rugosidade da superfície do phantom dentro do volume tratado. Acreditamos que esse trabalho mostra uma possibilidade de melhora na dosimetria para fototerapias. / The light propagation and distribution studies in biological media are importante for several phototherapy and diagmostic aplications. The biological tissues are considered turbida medias, where there is absortion and scattering combination, and determinate the light behavior inside this tissues have been studied by models that has some limitations.Then, to determine and control the light distribution to improve the light dose delivery is important for the treatment successful. For particular cases, such as Photodynamic Therapy (PDT) applied on smooth planar lesions treatments is appropriated, since there is a good possibility of uniform distribution of light within the tissue of the treated lesion. On the other hand, tumors with more thickness may not receive the needed doses of energy to cause its death. For an efficient treatment by photodynamic therapy is required an optimal coupling light inside the lesion tissue. Shadow effects, slits or physical irregularities in the lesion can lead a nonhomogeneous light distribution inside the tissue. The results can be a partial necrosis regions and tumor recurrence. Therefore it is crucial improving the light profile inside the tissue to overcome these problems. In this study, we measured the light profile inside the phantom after the light passing through a gel as coupler. We used a solid phantom as biological tissue model and was used a red laser (λ = 630 nm) as light source with an optical fiber to direct illumination. The coupling is controlled by introducing a gel with low concentration of scatters between the fiber and de phantom. Was collected pictures of light profile with a camera and the data were processed with MatLab software. Our results shows a strong improvement in the light distribution when the gel with scatters is positioned between fiber and tissue. In fact, a more homogeneous laser bean is delivered to tissue promoting a better light distribution. This technique eliminates drastically the roughness effect of the phantom surface in the bulk. We believe that this work shows a possibility of dosimetry improvement for phototherapy.
|
48 |
Alterações agudas da tireoide após radioterapia não dirigida à glândula em crianças e adolescentes, e dosimetria in vivo para a tireoide de diferentes regiões corporais irradiadasBonato, Cassiane Cardoso January 2012 (has links)
Purpose: To assess acute changes in thyroid function and volume in children and adolescents undergoing external radiation therapy for a variety of non-thyroid cancers. Methods and Materials: The study sample comprised 31 children and adolescents undergoing radiation therapy of various body areas in which the thyroid was outside the main beam. Thyroid-stimulating hormone (TSH), thyroxine (T4), free thyroxine (fT4), triiodothyronine (T3), anti-thyroperoxidase (anti-TPO) antibodies and thyroglobulin (Tg) were measured before radiation therapy, on the last day of irradiation, and 1 month and 3 months after the end of radiation therapy. Ultrasound and 6-hour and 24-hour 131I uptake were also performed before and after treatment. The scattered dose to the thyroid region was estimated with a treatment planning system (TPS) or measured with thermoluminescent dosimeters (TLDs). Results: The median radiation dose scattered to the thyroid was 296.6 cGy (IQR 16.7–1709.0). Levels of TSH (P=0.575), T4 (P=0.950), fT4 (P=0.510), T3 (P=0.842), Tg (P=0.620), and anti-TPO antibodies (P=0.546) were statistically similar at all four points in time. Younger subjects had higher T4, T3 and Tg levels, and T4 was highest in girls. There were no differences between pre- and post radiotherapy thyroid volume and 131I uptake (P=0.692 and 0.92, respectively). Conclusion: The radiation doses scattered to the thyroid in this sample were not associated with acute changes in thyroid function or volume. More sensitive methods may be required to ascertain whether acute injury to the follicular epithelium occurs with lower radiation doses.
|
49 |
Dosimetria de elétrons em processos de irradiação com diodos resistentes a danos de radiação / Electron dosimetry in irradiation processing with rad-hard diodesSantos, Thais Cavalheri dos 28 September 2012 (has links)
Este trabalho teve como objetivo o desenvolvimento de sistemas dosimétricos baseados em diodos especiais de Si, resistentes a danos de radiação, para monitoração online de processos de irradiação com elétrons de 1,5 MeV de energia e para dosimetria relativa e escaneamento de feixe de elétrons clínicos dentro de uma faixa de energia de 6 a 21 MeV. Os diodos utilizados foram produzidos pelos métodos de fusão zonal padrão (FZ), Czochralski em presença de um campo magnético (MCz) e crescimento Epitaxial (EPI). Para utilizar os diodos como detectores, eles foram fixados em uma base de alumina permitindo a ligação dos eletrodos de polarização e de extração de sinais. Após a montagem na base, cada diodo foi fixado em uma sonda acrílica preta dotada de uma janela de Mylar® aluminizado e de conector do tipo LEMO®. Com os dispositivos operando em modo fotovoltaico, a integração dos sinais de corrente em função do tempo de irradiação permitiu obter a carga produzida no volume sensível de cada diodo irradiado. O acelerador de elétrons utilizado para as irradiações de doses altas foi o DC 1500/25/4 - JOB 188 de 1,5 MeV instalado no Centro de Tecnologia das Radiações do IPEN/CNEN-SP. Foram estudados o perfil da corrente em função do tempo de exposição, a repetibilidade de resposta, a sensibilidade em função da dose absorvida e a curva resposta de cada dispositivo. Foi observada uma queda na sensibilidade mais acentuada para o diodo MCz do que para o diodo FZ e uma boa repetibilidade nos dois casos. Ainda, o aumento da carga com a dose absorvida obedeceu a uma função polinomial de segunda ordem. Na caracterização do diodo EPI, ele exibiu melhor repetibilidade que a obtida por dosímetros CTA, rotineiramente aplicados em processamento por radiação. Os resultados acima descritos indicam a potencial utilização desses diodos de Si resistentes a danos de radiação em dosimetria online para aplicações envolvendo elevadas doses. Para as irradiações de doses baixas foram utilizados os Aceleradores Lineares KD2 e Primus, ambos fabricados pela Siemens e instalados no Hospital Sírio-Libanês. A resposta dos diodos foi avaliada para energias de 6 a 21 MeV. Foram estudados: a repetibilidade de resposta, a curva dose-resposta em função da dose absorvida, a sensibilidade em carga com a energia do feixe de elétrons, a porcentagem de dose profunda (PDP) e o perfil transversal de dose. Apesar da resposta dos diodos FZ, MCz e EPI serem levemente dependentes da energia do feixe de elétrons, a resposta dosimétrica, em todo o intervalo de energia de feixe estudado, mostrou-se linear. Ainda, em relação aos diodos epitaxiais, os dispositivos estudados mostraram excelente acordo com simulações de Monte Carlo e medições realizadas com MatriXX®, demonstrando que os dispositivos podem ser usados como dosímetros em elétrons radioterápicos para escaneamento de varredura de feixe, mapeamento de distribuições de dose de feixes, monitoramento rotineiro da constância do fator calibração e dosimetria relativa. / This work had the aim of the development of dosimetric systems based on Si special diodes, resistant to radiation damage to online monitoring of irradiation processing using 1.5 MeV electrons energy and for relative dosimetry and clinical electron beam scanning within an energy range of 6 MeV up to 21 MeV. The diodes used were produced by Float Zone standard (FZ), Magnetic Czochralski (MCz) and epitaxy growth (EPI) methods. In order to use the diodes as detectors, they were fixed on alumina base to allow the connection of the polarization electrodes and the signals extraction. After the diode assembly on the base, each one was housed in a black acrylic probe with aluminized Mylar® window and LEMO® connector. With the devices operating in photovoltaic mode, the integration of the current signals as a function of irradiation time allowed obtain the charge produced in the sensitive volume of each diode irradiated. The electron accelerator used for high doses irradiation was the DC 1500/25/4 JOB 188 of the 1.5 MeV installed at the Radiation Technology Center of the IPEN/CNEN-SP. The current profile as function of exposure time, the response repeatability, the sensitivity as function of absorbed dose and the dose response curve were studied for each device. In comparison to FZ diode, we observed a greater decrease in the sensitivity for MCz diode, and good repeatability in both cases. Also, the increasing of the charge with the absorbed dose was well fitted by a second order polynomial function. In the EPI diode characterization, this one exhibited repeatability better than CTA dosimeters applied routinely in radiation processing. The above results indicate the potential use of these radiation hardness Si diodes in online dosimetry to high doses applications. For low doses irradiation were used the linear accelerators KD2 and Primus, both manufactured by Siemens and located at Sirio-Libanês Hospital. The diodes responses were evaluated for electron beams within the energy range of 6 MeV up to 21 MeV. The following studies were carried out: the short-term repeatability, the dose-response curve as a function of absorbed dose, the charge sensitivity as function of electron beam energy, the percentage depth dose (PPD) and the dose transversal profile. Despite the response of the diodes FZ, MCz and EPI be slightly dependent on the electron beam energy, the dosimetric response was linear in all electron beam energy range studied. In addition to this, the EPI devices showed excellent agreement with simulation performed with Monte Carlo code and the measurements performed with MatriXX®, confirming that the devices can be used as dosimeters in radiotherapy for scanning purposes, dose distribution mapping, constancy monitoring of calibration factor and relative dosimetry.
|
50 |
Um novo dosímetro de eletreto para radioterapia. / A new electrect dosimeter for radiotherapy.Rodrigues, Laura Natal 12 August 1985 (has links)
Neste trabalho apresentamos os resultados obtidos com um novo dosímetro de eletreto plano para uso em Radioterapia. O princípio de funcionamento do dosímetro de eletreto se baseia na utilização do campo do eletreto como o campo coletor de íons, em um sistema análogo ao da câmara de ionização, e ainda, corno um detector para a carga integrada. O modelo inicial do dosímetro possuía urna geometria cilíndrica. Através das curvas de calibração deste dosímetro, onde analisamos a sensibilidade, reprodutibilidade, estabilidade e, ainda, a dependência da sensibilidade com o volume e a pressão, concluímos que para aumentar a sua faixa útil de exposição, deveríamos construir um dosímetro com geometria plana. Estudamos a dependência da sensibilidade do dosímetro plano com as condições de carregamento do eletreto, volume da câmara e material da parede (alumínio, latão e aço inox) e os melhores resultados foram obtidos com o dosímetro de aço inox. Comparamos o comportamento deste sistema dosimétrico com um dosímetro Baldwin-Farmer, comumentemente usado em Radioterapia e verificamos que os resultados se mostraram satisfatórios. As características finais deste dosímetro são as seguintes: sensibilidade de 10-13C/R, volume de 0.20 cm3, reprodutibilidade de 5% e alcance máximo de exposição de 700 R. Finalmente, desenvolvemos um dosímetro múltiplo de eletreto para a medida da uniformidade do feixe de radiação para um aparelho de Cobaltoterapia. Os resultados da sua intercomparação com o dosímetro Baldwin-Farmer apresentaram uma variação máxima de 3%. / This work presents the results obtained with a new plane electret dosemeter for use in Radiotherapy. The working principle of the electrets dosemeter in based on the use for the electret field the ion collecting field, similarly to an ionization chamber, and as charge integrator detector. The dosemeter had, initially, a cylindrical geometry. The results attained with its calibration curve concerning the sensitivity, the stability and the reproducibility lead to changes in the dosimeter geometry. A plane geometry dosemeter was built in order to increase the useful exposure range. The plane dosemeter sensitivity dependence was measured versus the electrets charging conditions, the chamber volume and wall material (aluminium, brass, and stainless steel). The stainless steel dosemeter showed the best results. This dosemeter has the following characteristics: sensitivity 10-13C/R, volume 0.20 cm3, reproducibility 5%, and maximum exposure range 700 R. Compared to the Baldwin-Farmer dosemeter, this results are fairly good. A multiple electret dosemeter was developed to monitor the uniformity of the radiation beam for a Cobalt teletherapy unit. The intercomparasion with the Baldwin-Farmer unit presented a maximum variation of 3%.
|