Return to search

Operação flexível de conversores trifásicos conectados à rede elétrica / Strategy for flexible operation of three-phase converters connected on Grid-tie

Submitted by ALESSANDRO LUCINDO DA LUZ null (aledaluz@hotmail.com) on 2018-01-10T01:24:32Z
No. of bitstreams: 1
Operacao flexivel conversores_ALuz.pdf: 10997918 bytes, checksum: 18fe1f6d3eba73d11bf63fab8cf0a0be (MD5) / Approved for entry into archive by Maria Marlene Zaniboni null (zaniboni@bauru.unesp.br) on 2018-01-10T11:41:48Z (GMT) No. of bitstreams: 1
luz_al_me_bauru.pdf: 10997918 bytes, checksum: 18fe1f6d3eba73d11bf63fab8cf0a0be (MD5) / Made available in DSpace on 2018-01-10T11:41:48Z (GMT). No. of bitstreams: 1
luz_al_me_bauru.pdf: 10997918 bytes, checksum: 18fe1f6d3eba73d11bf63fab8cf0a0be (MD5)
Previous issue date: 2017-11-13 / Este trabalho de mestrado descreve uma estratégia de operação multifuncional e flexível aplicado a conversores trifásicos CC-CA (inversores) conectados à rede de distribuição de energia elétrica. A estratégia proposta é capaz de injetar potência ativa na rede e compensar correntes de distúrbios (reativos, desbalanço e harmônicos) simultaneamente. O maior objetivo desta operação flexível é de melhorar a Qualidade de Energia Elétrica em um ponto de acoplamento comum (PAC) permitindo a compensação total ou parcial destes distúrbios ou fatores que degradam a Qualidade de Energia Elétrica. O fator de potência é o principal fator de qualidade a ser observado e ele é calculado através da Teoria da Potência Conservativa – CPT. Entretanto, com base no fator de potência medido pelo lado da rede de distribuição e o fator de potência desejado, um coeficiente de compensação – k é calculado para o ajuste das correntes de compensação dos distúrbios que geram a potência não ativa. / This paper depicts a multifunctional and flexible control strategy applied in three-phase inverters, which are connected to the distribution network. The proposed strategy is able to inject active power into the electrical grid and compensate current disturbances (reactive, harmonics and unbalance) simultaneously. The main goal of this flexible strategy is to improve the Power Quality at the point of common coupling (PCC) allowing full or partial compensation of disturbances. Power factor is the main quality index observed and it is calculated according to Conservative Power Theory - CPT. Therefore, based on the power factor measured in the grid side and the desired value for the power factor, a compensation coefficient - k is calculated continuously adjusting the amplitude of the compensation current.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/152449
Date13 November 2017
CreatorsLuz, Alessandro Lucindo da
ContributorsUniversidade Estadual Paulista (UNESP), Paredes, Helmo Kelis Morales [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation600

Page generated in 0.0037 seconds