Return to search

Uso do teste Lea Gratings para avaliação da acuidade visual de resolução de grades em lactentes normais / Using Lea Gratings test to access grating visual acuity in normal infants

Orientadores: Abimael Aranha Netto, André Moreno Morcillo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-21T16:08:29Z (GMT). No. of bitstreams: 1
Martini_Giovana_M.pdf: 6946196 bytes, checksum: 0958a806379064012236749e08f7a700 (MD5)
Previous issue date: 2012 / Resumo: Objetivos: Determinar o desenvolvimento da acuidade visual de grades binocular e monocular, mensuradas com o Lea Gratings, prover uma base idade-dependente por esta técnica em uma coorte de crianças saudáveis e comparar os resultados obtidos por este teste com os obtidos com os Cartões de Acuidade de Teller. Método: Tratou-se de estudo prospectivo e longitudinal, descritivo e analítico, da acuidade visual de resolução de grades de um grupo de lactentes, nos três primeiros meses de vida e no período entre 12 e 24 meses. Considerou-se, como critérios de inclusão, lactentes que foram nascidos a termo e adequados para a idade gestacional, com um mês de idade cronológica e residentes na região metropolitana de Campinas, que apresentaram o Reflexo Vermelho presente ao nascimento. A acuidade visual de resolução de grades foi mensurada por meio do teste Lea Gratings, mês a mês, e, a partir dos 12 meses, também por meio dos Cartões de Acuidade de Teller, quando foram descartadas alterações oftalmológicas nos participantes do estudo. A amostra foi constituída de 133 lactentes e a análise dos resultados foi realizada utilizando-se o Statistical Package for Social Sciences for Personal Computer (SPSS 16.0). Os valores de acuidade (CPD) foram apresentados em distribuição de frequência e para determinação da média e do desvio padrão, os dados foram transformados em escala de uma oitava. Para comparação da acuidade visual entre as idades foi utilizada a análise de variância para medidas repetidas e o de Wilcoxon para comparação das medidas entre os olhos para amostras relacionadas. A correlação entre os resultados obtidos pelos dois testes foi avaliada pelo Coeficiente de Correlação de Spearman. Resultados: Os valores de acuidade visual binocular foram crescentes, sendo obtida no primeiro mês a média de 0,55 cpd (±0,70), de 1,35 cpd (±0,69) no segundo mês e de 3,11 cpd (±0,54) no terceiro mês. A partir dos 12 meses, as médias dos valores de acuidade visual binocular e monocular - foram, respectivamente, de 14,41 cpd (±0,25) e de 12,03 cpd (±0,39) nas crianças com idade entre 12 e 14 meses, de 14,10 cpd (±0,27) e de 10,79 cpd (±0,42) em crianças com idade entre 15 e 18 meses e de 15,50 cpd (±0,13) e de 13,42 cpd (±0,26) em crianças com idade entre 19 e 24 meses. Os resultados da análise de variância demonstraram diferenças significativas nos valores de acuidade visual entre todas as idades. Os coeficientes de Correlação de Spearman entre os testes Lea Gratings e Cartões de Acuidade de Teller foram de 0,53505 e de 0,65175 para, respectivamente, as medidas binocular e monocular. Conclusão: O teste foi capaz de avaliar a evolução da acuidade visual no primeiro trimestre de vida e no período entre 12 a 24 meses, e permitiu o fornecimento de uma base idade-dependente por esta técnica em uma coorte de lactentes saudáveis até o período de 12 meses. A comparação entre os dois testes de acuidade visual de grades demonstrou correlação positiva / Abstract: Purpose: This study aims to determine the development of the binocular and monocular grating acuity with Lea Gratings, to established age-related norms for this method in a health children cohort and comparing the results obtained by this test with those obtained with the Teller Acuity Cards. Methods: This was a prospective and longitudinal study, descriptive and analytic, of infant grating visual acuity in the first three months of life and between the ages 12 and 24 months. The sample was composed of infants that met the following criteria: full-term infants appropriate for gestational age, with a chronological age of one month, residents in the Campinas metropolitan region, born with positive red reflex and whose parents consented to participate in this study. The grating acuity of each infant was measured three times at regular intervals, using Lea Gratings, and after 12 months, also with the Teller Acuity Cards, when a complete ophthalmologic examination was conducted to reject any visual alteration. The final sample was composed of 133 infants and the results were analyzed with the Package for Social Sciences for the Personal Computer (SPSS 16.0). The grating acuity results were stated in frequency tables and converted into a one-octave scale for statistical calculation. Repeated measure analysis of variance was applied to compare the grating acuity results among ages. The Wilcoxon test was used to compare the measures between the eyes in related samples and the Spearman Correlation was applied to evaluate the results obtained with the two tests. Results: The binocular grating acuity measures were crescent. In the first month, the mean acuity was 0.55 cpd (±0.70); in the second month, the mean acuity was 1.35 cpd (±0.69) and in the third month it was 3.11 (±0.54). After 12 months, the means of binocular and monocular acuity were, respectively, 14.41 cpd (±0.25) and 12.03 cpd (±0.39) in children between ages 12 and 14 months; 14.10 cpd (±0.27) and 10.79 cpd (±0.42) in children between ages 15 and 18 months; 15.50 cpd (±0.13) and 13.42 cpd (±0.26) in children between ages 19 and 24 months. Analysis of variance to repeated measures indicated differences between the measures of grating acuity in all ages. The coefficient of Spearman Correlation between the tests Lea Gratings and Teller Acuity Cards was respectively 0.53505 and 0.65175 for binocular and monocular measures. Conclusions: This test was capable to assess the evolution of grating acuity in the first three months of life and between 12 and 24 months, and established age-related norms for this method in a health children cohort until 12 months age. The comparison between the two tests of grating acuity demonstrated positive correlation / Mestrado / Saude da Criança e do Adolescente / Mestra em Saúde da Criança e do Adolescente

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/313679
Date21 August 2018
CreatorsMartini, Giovana, 1979
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Morcillo, André Moreno, 1950-, Aranha Netto, Abimael, 1958-, Graziano, Rosa Maria, Marba, Sérgio Tadeu Martins
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Saúde da Criança e do Adolescente
Source SetsIBICT Brazilian ETDs
LanguageMultilíngua
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format165 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0033 seconds