Return to search

Detec??o e diagnostico de agarramento em v?lvulas posicionadoras

Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-03-02T22:51:52Z
No. of bitstreams: 1
AllanRobsonSilvaVenceslau_DISSERT.pdf: 4005156 bytes, checksum: 19abdee5a925ca31403b67505767b149 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-03-03T23:46:03Z (GMT) No. of bitstreams: 1
AllanRobsonSilvaVenceslau_DISSERT.pdf: 4005156 bytes, checksum: 19abdee5a925ca31403b67505767b149 (MD5) / Made available in DSpace on 2016-03-03T23:46:03Z (GMT). No. of bitstreams: 1
AllanRobsonSilvaVenceslau_DISSERT.pdf: 4005156 bytes, checksum: 19abdee5a925ca31403b67505767b149 (MD5)
Previous issue date: 2013-01-31 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico - CNPq / Agarramento, ou atrito est?tico, em v?lvulas posicionadoras ? um problema muito
comum nos processos industriais modernos. Recentemente, muitos estudos s?o desenvolvidos
para tentar entender, modelar e detectar esse tipo de problema. Por?m quantificar o
agarramento ainda ? um desafio. Uma vez que a posi??o da v?lvula (mv) ? normalmente
desconhecida em um processo industrial, o principal desafio ? diagnosticar agarramento
tendo conhecimento apenas dos sinais de sa?da do processo (pv) e o sinal de controle (op).
Neste trabalho ? apresentada uma proposta baseada em Redes Neurais Artificiais para detectar
e quantificar o grau de agarramento em v?lvulas utilizando apenas as informa??es
de pv e op. Diferentes m?todos para o pr?-processamento do conjunto de treinamento da
Rede Neural s?o apresentados. Esses m?todos s?o baseados no c?lculo de Centroide e de
Transformada de Fourier. A proposta ? validada atrav?s de um processo simulado e os
resultados obtidos foram satisfat?rios. / Valve stiction, or static friction, in control loops is a common problem in modern industrial
processes. Recently, many studies have been developed to understand, reproduce
and detect such problem, but quantification still remains a challenge. Since the valve position
(mv) is normally unknown in an industrial process, the main challenge is to diagnose
stiction knowing only the output signals of the process (pv) and the control signal (op).
This paper presents an Artificial Neural Network approach in order to detect and quantify
the amount of static friction using only the pv and op information. Different methods for
preprocessing the training set of the neural network are presented. Those methods are based
on the calculation of centroid and Fourier Transform. The proposal is validated using
a simulated process and the results show a satisfactory measurement of stiction.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufrn.br:123456789/19934
Date31 January 2013
CreatorsVenceslau, Allan Robson Silva
Contributors21929564287, http://lattes.cnpq.br/7987212907837941, Silva, Diego Rodrigo Cabral, 00973116420, http://lattes.cnpq.br/1125827309642732, Moreira, Vicente Delgado, 02118457448, http://lattes.cnpq.br/4549279470957332, Oliveira, Luiz Affonso Henderson Guedes de
PublisherUniversidade Federal do Rio Grande do Norte, PROGRAMA DE P?S-GRADUA??O EM ENGENHARIA EL?TRICA E DE COMPUTA??O, UFRN, Brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFRN, instname:Universidade Federal do Rio Grande do Norte, instacron:UFRN
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0091 seconds