Return to search

Estudo da ventilação natural em edificações com captadores de vento multidirecionais por meio de ensaios em túnel de vento e simulações computacionais / Study of natural ventilation in buildings with multidirectional wind catchers through wind tunnel testing and computer simulations

Orientador: Lucila Chebel Labaki / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-24T13:55:02Z (GMT). No. of bitstreams: 1
Andrade_NixonCesarde_D.pdf: 32217441 bytes, checksum: 25e8b1672ea93f3aae90a2513264ae3e (MD5)
Previous issue date: 2013 / Resumo: A ventilação natural é uma das estratégias mais adequadas para o resfriamento passivo dos edifícios e para a manutenção da qualidade do ar. Uma das alternativas existentes para se alcançar tal proposição é a utilização de torres de vento situadas acima do nível da cobertura, as quais podem funcionar como captadores ou extratores de ar. Esta pesquisa tem como objetivo geral avaliar quatro tipos de torres, atuando como captadores: a unidirecional, com uma abertura para a entrada de vento, em locais onde o vento se movimenta predominantemente em uma direção; a tetradirecional, com quatro aberturas; a octodirecional, com oito aberturas e a dodecadirecional, com doze aberturas; em locais em que o vento age em várias direções. Para alcançar o objetivo utilizaram-se ensaios em túnel de vento e simulações no software CFX®, os quais permitiram estudar as características técnicas das torres analisadas e seus efeitos sobre a ventilação interna do ambiente, bem como contribuir para a difusão desse sistema de ventilação no Brasil. O desenvolvimento do trabalho foi dividido nas seguintes etapas: definição das geometrias das torres; definição, construção e instrumentação das maquetes; definição dos ângulos de incidência do vento; ensaios no túnel de vento e simulações no software CFX®: velocidade e pressão. Os resultados obtidos a partir de uma série de experimentos e simulações computacionais permitiram a análise e comparação dos diversos projetos propostos, auxiliando, portanto, na determinação das configurações mais adequadas, além da verificação da compatibilidade entre os dois tipos de estudo, concluindo que as torres octodirecional e dodecadirecional são as mais eficientes, pois proporcionam maiores valores de velocidade do ar interno na maioria das posições consideradas. Desta forma, utilizando o túnel de vento e o CFX®, as análises possibilitaram desenvolver melhorias para os ambientes avaliados, no que se refere ao desempenho da ventilação. Isso proporcionará melhores taxas de conforto aos usuários da edificação, considerando todas as aberturas para permitir o fluxo do vento em qualquer situação. Ademais, podem-se verificar as distribuições das aberturas de entrada e saída mais adequadas para captação e distribuição do vento no interior dos ambientes, proporcionando melhores condições de conforto térmico / Abstract: Natural ventilation is one of the most appropriate strategies for passive cooling of buildings and the maintenance of air quality. One of the alternatives for achieving such proposal is the use of wind towers above the level of the roof, which can function as air catchers or extractors. This research aims to evaluate four types of towers, acting as air catchers: unidirectional, with an opening for the entrance of the wind, in locations where the wind moves predominantly in one direction, the tetradirectional, with four openings, the octodirectional, with eight openings and dodecadirectional, with twelve openings, in locations where the wind moves in various directions. To achieve the goal, tests in wind tunnel and simulations in CFX® software were performed, which allowed the study of the technical characteristics of the analyzed towers and their effects on the indoors ventilation, as well as the contribution to the spread of this ventilation system in Brazil. The methodology was divided into the following steps: the definition of the geometry of the towers; definition, construction and instrumentation of the models; definition of the angles of the incidence of the wind; wind tunnel tests and simulations in CFX® software: speed and pressure. The obtained results from a series of experimental and computational simulations allowed the analysis and comparison of the various proposed design configurations, helping, therefore, in determining the most appropriate settings, besides the verification of compatibility between the two types of study, concluding that the octodirectional and dodecadirectional towers are the most efficient ones , as they provide higher rate of indoor air speed in most considered positions. Thus, using the wind tunnel and CFX®, the analysis allowed the development of enhancements to the analyzed environments, concerning the performance of the ventilation. This will provide better comfort rates to the users of the building, considering all openings to allow the wind flow in any situation. Furthermore, the most suitable distribution of inlet and outlet openings for the catchment and distribution of the wind within the environments may be verified, providing better conditions of thermal comfort / Doutorado / Arquitetura e Construção / Doutor em Engenharia Civil

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258056
Date24 August 2018
CreatorsAndrade, Nixon Cesar de, 1976-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Labaki, Lucila Chebel, 1943-, Kowaltowski, Doris Catharine Cornelie Knatz, Vatavuk, Paulo, Souza, Henor Artur de, Bittencourt, Leonardo Salazar
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil
Source SetsIBICT Brazilian ETDs
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format284 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds