Return to search

Experimental and numerical investigation of noise generation from the expansion of high velocity HVAC flows on board ocean going fast ferries

This thesis details a study of strategies used to limit the flow generated noise encountered in the outlet diffusers of high velocity heating, ventilation and air conditioning (HVAC) duct systems. The underlying noise rating criterion is drawn from the specifications covering ocean going aluminium fast ferries. Although directed primarily towards the fast ferry industry the results presented herein are applicable to other niche high velocity HVAC applications. Experimental tests have been conducted to prove the viability of a high velocity HVAC duct system in meeting airflow requirements whilst maintaining acceptable passenger cabin noise levels. A 50 mm diameter circular jet of air was expanded using a primary conical diffuser with a variety of secondary outlet configurations. Noise measurements were taken across a velocity range of 15 to 60 m/s. An optimum outlet design has been experimentally identified by varying the diffuser angle, outlet duct length and the termination grill. A 4 to 5 fold reduction in required duct area was achieved with the use of a distribution velocity of 20 to 30 ms-1, without exceeding the prescribed passenger cabin noise criteria. The geometric configuration of the diffuser outlet assembly was found to have a pronounced effect on the noise spectrum radiating from the duct outlet. The development of a numerical model capable of predicting the flow induced noise generated by airflow exiting a ventilation duct is also documented. The model employs a Large Eddy Simulation (LES) CFD model to calculate the turbulent flow field through the duct diffuser section and outlet. The flow-generated noise is then calculated using a far field acoustic postprocessor based on the Ffowcs-Williams and Hawkings integral based formulation of Lighthill???s acoustic analogy. Time varying flow field variables are used to calculate the fluctuating noise sources located at the duct outlet and the resulting far field sound pressure levels. This result is then used to calculate the corresponding far field sound intensity and sound power levels. The numerical acoustic model has been verified and validated against the measured experimental results for multiple outlet diffuser configurations.

Identiferoai:union.ndltd.org:ADTP/257330
Date January 2006
CreatorsNeale, James Richard, Mechanical & Manufacturing Engineering, Faculty of Engineering, UNSW
PublisherAwarded by:University of New South Wales. School of Mechanical and Manufacturing Engineering
Source SetsAustraliasian Digital Theses Program
LanguageEnglish
Detected LanguageEnglish
RightsCopyright James Richard Neale, http://unsworks.unsw.edu.au/copyright

Page generated in 0.002 seconds