EVALUATING THE ORGANIC RANKINE CYCLE (ORC) FOR HEAT TO POWER : Feasibility and parameter identification of the ORC cycle at different working fluid with district waste heat as a main source.

New technologies to converting heat into usable energy are constantly being developed for renewable use. This means that more interactions between different energy grid will be applied, such as utilizing low thermal waste heat to convert its energy to electricity. With high electricity price, such technology is quite attractive at applications that develop low waste heat. In the case of excess heat in district heating (DH) grid and the electricity price are high, the waste heat can be converted to electricity, which can bring a huge profit for DH companies. Candidate technologies are many and the focus in this degree rapport is on the so-called Organic Rankine Cycle (ORC) that belongs to the steam Rankine cycle. Instead of using water as a working fluid, organic working fluid is being used because of its ability to boil at lower temperature. Because this technique is available, it also needs to be optimized, developed, etc. to achieve the highest appropriate efficiency. This can be done, for example, by modeling different layouts, analyzing functionality, performance and / or do a simulation of various suitable working fluids.  This is the purpose of this degree project and the research parts are to select working fluids suitable at low temperatures (70-120) °C, the difference analysis between the selected fluids and identification of the parameters that most affect the performance. There are many suitable methods to apply to achieve desired results. The method used in this rapport degree is commercial software such as Mini REFPROP, CoolPack, Excel but the most important part is simulation with AspenPlus. The selected and suitable working fluids between the chosen temperature interval are R236ea, R600, R245fa and n-hexane. Three common layouts were investigated, and they are The Basic ORC, ORC with an internal heat exchanger (IHE) and regenerative ORC. The results show that in comparison between 120°C and 70°C as a temperature source and without an internal heat exchanger (IHE), R600 at 70°C, has the highest efficiency about 13.55%. At 110°C n-hexane has the highest efficiency about 18.10%. R236ea has the lowest efficiency 13.16% at 70°C and 16.29% at 110°C. R236ea kept its low efficiency through all results. Without an IHE and a source range from 70 °C up to almost 90 °C, R600 has the highest efficiency and at 90°C n-hexane has the highest efficiency. With an IHE and between (70-90) °C R245fa still has the highest efficiency. With or without IHE and a heat source of 110 °C n-hexane has the highest efficiency 18.10% and 18.40%. R236ea gets the greatest increase 5.2% in efficiency but remains with the lowest efficiency. With Regenerative ORC, n-hexane had an optimal middle pressure about 0.76 bar. The optimal pressure corresponds to a thermal efficiency of 17.52%. The most important identified parameters are the fluid characteristics such as higher critical temperature, temperature source, heat sink, application placement and component performance.         The current simulations have been run at some fixed data input such as isentropic efficiencies, no pressure drops, adiabatic conditions etc. It was therefore expected that the same efficiency curve would repeat itself. This efficiency pattern would differ with less or higher values depending on the layout performance. However, this pattern was up to 90 degrees Celsius and gets a very noticeable change by the change of the efficiency for n-hexane. Therefore n-hexane is chosen with Regenerative ORC because it had the highest efficiency at the highest temperature source tested. This is due definitive to the fluid properties like its high critical temperature compared to the other selected fluids. R236ea remains the worst and that’s also related to the fluid properties. It is also important to note that these efficiencies are only from a thermodynamic perspective and may differ when combining both thermal and economic perspectives as well as application placement. These high efficiencies will certainly be lower at more advanced or real processes due to various factors that affect performance. Factors such as component´s efficiency and selection, pipe type and size, etc. To maintain a constant temperature when it’s not, flow regulation is then necessary and that’s also affects the performance.   The conclusion is that the basic ORC which does not have an IHE and from 70 up to 90 degrees Celsius, R600 has the highest efficiency. Higher temperature gives n-hexane the highest efficiency. With an IHE and between (70-90) °C R254fa has the highest efficiency. At higher temperature source n-hexane has the highest efficiency. ORC with an IHE has the best performance. The R236ea has the worst performance through all results. With regenerative ORC, an optimal meddle-pressure for n-hexane is 0.76 bar. Important parameters are The properties of the fluid, temperature source, heatsink, Application placement and component performance. / Nej

Identiferoai:union.ndltd.org:UPSALLA1/oai:DiVA.org:mdh-38573
Date January 2017
CreatorsMohamad, Salman
PublisherMälardalens högskola, Framtidens energi
Source SetsDiVA Archive at Upsalla University
LanguageEnglish
Detected LanguageEnglish
TypeStudent thesis, info:eu-repo/semantics/bachelorThesis, text
Formatimage/png, image/png, image/png
Rightsinfo:eu-repo/semantics/openAccess, info:eu-repo/semantics/openAccess, info:eu-repo/semantics/openAccess

Page generated in 0.002 seconds