Macular pigment optical density measurements by one-wavelength reflection photometry – Influence of cataract surgery on the measurement results

Purpose:
The main objective of the present study was the investigation of possible influence of lens opacification on macular pigment optical density (MPOD) measurements.
Methods:
86 eyes of 64 patients (mean age 73.4(±8.3)years) were included in the study. MPOD was prospectively measured using one-wavelength reflection method (Visucam500, Carl Zeiss Meditec AG) before and after cataract extraction with implantation of a blue-light filtering intraocular lens (AlconSN60WF). The median of the maximum optical density (MaxOD) and the median of the mean optical density (MeanOD) measurements of macular pigment across the subject group were evaluated.
Results:
Statistically significant differences were noticed between pre-operative and post-operative measurements, the absolute values were generally lower after cataract extraction. The following median(lower/upper quartile) differences across the group were determined: MaxOD -33.8%(-46.2%/-19.1%), MeanOD -44.0%(-54.6%/-26.6%). Larger changes were observed in elderly patients (<70years of age: (n=25eyes) MaxOD -13.4%(-20.5%/3.6%), MeanOD -23.6%(-30.5%/-15.3%) versus patients ≥70years: (n=61eyes) MaxOD -40.5%(-53.2%/-30.1%), MeanOD -47.2%(-57.8%/-40.1%)) and in patients with progressed stage of cataract. MaxOD for lens opacification grade 1:(n=9eyes) -27.4%(-42.1%/-19.6%), 2:(n=26eyes) -35.0%(-44.2%/-25.3%), 3:(n=21eyes) -34.4%(-45.4%/-11.4%), 4:(n=25eyes) -32.6%(-53.2%/-6.4%) and 5:(n=5eyes) -53.5%(-61.7%/-38.7%) and MeanOD for cataract stage 1:(n=9eyes) -42.6%(-46.0%/-26.0%), 2:(n=26eyes) -44.1%(-51.8%/26.2%), 3:(n=21eyes) -45.7%(-54.7%/-24.7%), 4:(n=25eyes) -39.5%(-59.4%/-26.1%), 5:(n=5eyes) -57.0%(-66.1%/-51.4%).
Conclusions:
As established by comparison of pre- to post-operative measurements, cataract presented a strong effect on MPOD measured by one-wavelength reflection method. Particular care should therefore be taken when evaluating MPOD using this method in elderly patients with progressed stage of cataract. Future optimization of correcting parameters of scattered light and consideration of cataract influence may allow more precise evaluation of MPOD.

Identiferoai:union.ndltd.org:DRESDEN/oai:qucosa:de:qucosa:12325
Date18 June 2015
CreatorsKomar, Bogdana
ContributorsDawczynski, Jens, Reichenbach, Andreas, Blum, Marcus, Universität Leipzig
Source SetsHochschulschriftenserver (HSSS) der SLUB Dresden
LanguageEnglish
Detected LanguageEnglish
Typedoc-type:doctoralThesis, info:eu-repo/semantics/doctoralThesis, doc-type:Text
Rightsinfo:eu-repo/semantics/openAccess