Nesse estudo investigamos os efeitos da hipóxia tecidual aguda (HA) sobre as propriedades eletrofisiológicas intrínsecas dos neurônios pré-simpáticos bulboespinhais da área rostro-ventrolateral do bulbo (RVLM) de ratos jovens adultos submetidos previamente à hipóxia crônica intermitente (HCI) e os seus respectivos controle. Para marcarmos os neurônios pré-simpáticos bulboespinhais da RVLM, ratos Wistar jovens (P19-P21) anestesiados com ketamina e xilazina, receberam microinjeções bilaterais de rodamina, um traçador fluorescente retrógrado, na coluna intermediolateral da medula espinhal (T3-T6) e 2 dias após a recuperação da cirurgia, os animais foram submetidos ao protocolo de HCI, enquanto que ratos controle foram mantidos em condições de normóxia, durante 10 dias. No décimo primeiro dia, os ratos foram novamente anestesiados para a remoção do cérebro e as fatias do tronco cerebral contendo neurônios pré-simpáticos com marcação positivas foram registrados. Utilizamos a técnica de whole cell patch-clamp para estudo das propriedades eletrofisiológicas desses neurônios. As propriedades eletrofisiológicas intrínsecas foram analisadas antes e após a HA, a qual foi produzida pela perfusão das fatias do tronco cerebral com uma solução hipóxica (95% N2 + 5% CO2) durante 2 minutos na presença de bloqueadores sinápticos excitatórios e inibitórios. Todos os neurônios pré-simpáticos apresentaram característica intrínseca de autodespolarização e a frequência de disparos basal de potenciais de ação (PAs) desses neurônios de ratos do grupo controle e HCI foram similares [Controle= 5,03 ± 0,4 Hz (n=39) vs HCI= 6,31 ± 0,7 Hz (n=31); p > 0,05]. No grupo controle, a HA não alterou a frequência média de disparos de PAs (BS = 5,03 ± 0,4 Hz vs HA = 5,24 ± 0,3 Hz (n=39); p > 0,05], porém revelou diferentes perfis de disparo de PAs após 2 min de exposição à HA: i) 11 neurônios com aumento na frequência de disparos (BS = 5,1 ± 0,7 Hz vs HA = 7 ± 0,7 Hz; p < 0,05]; ii) 21 neurônios sem alteração na frequência de disparos (BS = 4,8 ± 0,5 Hz vs HA = 5,36 ± 0,6 Hz; p > 0,05] e iii) 7 neurônios com diminuição na frequência de disparos (BS = 7,3 ± 1,1 Hz vs HA = 3,6 ± 0,7 Hz; p < 0,05). No grupo HCI, a HA produziu aumento na frequência média de disparos (BS= 6,31 ± 0,7 Hz vs HA= 7,25 ± 0,8 Hz; n=31 - p < 0,05) e na análise do perfil de disparo de PAs, a HA revelou 2 subpopulações: i) 9 neurônios com aumento na frequência de disparos (BS = 4,7 ± 0,8 Hz vs HA = 8,2 ± 1,4 Hz; p < 0,05) e ii) 22 neurônios sem alteração na frequência de disparos (BS = 7,0 ± 1,0 Hz vs HA = 6,8 ± 1,0 Hz; p > 0,05). Esse estudo nos permitiu revelar diferentes subpopulações de neurônios pré-simpáticos que responderam de forma distintas à HA. Os resultados também sugerem que a HCI teria um efeito pré- condicionante na excitabilidade intrínseca dos neurônios pré-simpáticos em resposta à HA / In this study we evaluated the effects of acute hypoxia (AH) on the intrinsic electrophysiological properties of presympathetic neurons from rostro ventrolateral medulla (RVLM) of juvenile rats exposed to chronic intermittent hypoxia (CIH) or normoxic condition (control group). To label the RVLM bulbospinal presympathetic neurons, young Wistar rats (P 19 - 21) anesthetized with ketamine and xylazine, received bilateral microinjections of a fluorescent retrograde tracer (rhodamine retrobeads) were performed into the intermediolateral column of spinal cord (T3-T6) and two days after recovery of the surgery, the animals were submitted to CIH or normoxic protocol, during 10 days. On the 11th day, under anesthesia, brainstem slices were obtained and only the labeled RVLM presympathetic neurons were recorded, using whole-cell patch-clamp approach to study the electrophysiological properties of these neurons. The intrinsic electrophysiological properties were analyzed before and after AH, which was produced by slice perfusion with hypoxic solution (95% N2 and 5% CO2) during 2 min in the presence of excitatory and inhibitory synaptic antagonists. All recorded RVLM presympathetic neurons presented intrinsic pacemaker activity and the baseline firing frequency of these neurons from control and CIH group were similar [Control= 5,03 ± 0,4 Hz (n=39) vs HCI= 6,31 ± 0,7 Hz (n=31); p > 0,05]. In the control group, AH do not change the firing rate (BS = 5,03 ± 0,4 Hz vs HA = 5,24 ± 0,3 Hz (n=39); p > 0,05), but revealed different pattern of firing frequency after 2 min of AH: i) 11 neurons increased the firing frequency (BS = 4,9 ± 0,9 Hz vs HA = 6,9 ± 1,0 Hz; p < 0,05) ; ii) 21 neurons do not change the firing frequency (BS = 4,8 ± 0,5 Hz vs HA = 5,36 ± 0,6 Hz; p > 0,05) and iii) 7 neurons decreased the firing frequency (BS = 7,3 ± 1,1 Hz vs HA = 3,6 ± 0,7 Hz; p < 0,05). In the CIH group, the AH increased the firing rate comparing with basal condition (SB= 6,31 ± 0,7 Hz vs AH= 7,25 ± 0,8 Hz; n=31 - p < 0,05) and analyzing the pattern of action potential, AH revealed 2 subpopulations in this group: i) 9 neurons increased the firing frequency (SB = 4,7 ± 0,8 Hz vs AH = 8,2 ± 1,4 Hz; p < 0,05) and ii) 22 neurons do not change the firing frequency (SB = 7,0 ± 1,0 Hz vs AH = 6,8 ± 1,0 Hz; p > 0,05).. The data shows that AH revealed different subpopulations of presympathetic neurons and suggest that CIH plays a preconditioning in the intrinsic excitability of presympathetic neurons in response to acute hypoxia
Identifer | oai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-20072016-143159 |
Date | 16 December 2015 |
Creators | Marlusa Karlen Amarante |
Contributors | Benedito Honório Machado, Gustavo Rodrigues Pedrino, Aldo Rogelis Aquiles Rodrigues, Wamberto Antonio Varanda |
Publisher | Universidade de São Paulo, Fisiologia, USP, BR |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Source | reponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0026 seconds