Avaliação ecocardiografica da terapia de ressincronização cardiaca : dois anos de seguimento / Echocardiographic assessment of the cardiac resynchronization therapy : two years of follow-up

Orientador: Salomon Soriano Ordinola Rojas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-12T15:05:14Z (GMT). No. of bitstreams: 1
Veiga_VivianeCordeiro_M.pdf: 4383215 bytes, checksum: 4ac235c87c9173ad91395fd7c6466208 (MD5)
Previous issue date: 2008 / Resumo: Introdução A terapia de ressincronização cardíaca é uma opção efetiva nos pacientes com insuficiência cardíaca avançada. No entanto, 20 a 30% dos pacientes não apresentam benefícios à esta terapêutica. Critérios clínicos, eletrocardiográficos e ecocardiográficos têm sido estudados na tentativa de selecionar os pacientes que serão beneficiados com a ressincronização cardíaca, sendo o ecocardiograma um método utilizado tanto na seleção, quanto na avaliação e otimização desta terapêutica. Objetivo: O objetivo deste trabalho é analisar a utilização do ecocardiograma na avaliação da terapia de ressincronização cardíaca em pacientes portadores de insuficiência cardíaca refratária, no seguimento a curto prazo (dez dias) e após dois anos de evolução. Casuística e Método: Foram avaliados 20 pacientes com indicação de implante de marcapasso biventricular para terapia de ressincronização cardíaca no período de dois anos, sendo 16 (80%) do sexo masculino, com idade variando de 27 a 80 anos (59,70 ± 12,59 anos). A etiologia da cardiomiopatia era isquêmica em 10 pacientes (50%), chagásica em seis (30%) e idiopática em 4 (20%). Quinze pacientes encontravam-se em classe funcional III (New York Heart Association) e cinco em classe funcional IV no momento do implante do marcapasso. Foi aplicado o Questionário de Qualidade de Vida de Minnesota e realizado o teste de caminhada de seis minutos para avaliação das condições clínicas dos pacientes. Realizado ecodopplercardiograma bidimensional para avaliação da função ventricular, diâmetros cavitários, índice de performance miocárdica, estudo da dissincronia interventricular (avaliação do atraso eletromecânico entre os ventrículos esquerdo e direito) e intraventricular (análise pelo modo unidimensional e Doppler tecidual), da função diastólica e do grau da regurgitação mitral. Dez dias após o implante do marcapasso biventricular, foi repetida toda a avaliação inicial e, novamente, após dois anos. Resultados: Em dois anos, cinco pacientes (25%) foram à óbito, sendo que destes, quatro apresentavam etiologia chagásica. A duração média do complexo QRS era de 154,5±18,48 x 129,0±22,91 x 134,0±24,14 ms, respectivamente nos períodos pré-operatório, dez dias e dois anos de pós-operatório. Não houve alteração estatisticamente significante da fração de ejeção entre os períodos pré-operatório e dez dias, mas houve alteração significante entre os períodos pré-operatório e dois anos e dez dias e dois anos. No seguimento de dez dias, houve piora da dissincronia intraventricular avaliada pelo Doppler tecidual, assim como a pontuação no escore de qualidade de vida foi maior, no grupo óbito. Conclusão: A ecocardiografia é uma tecnologia em evolução e dos parâmetros avaliados, somente a avaliação da dissincronia intraventricular pelo Doppler tecidual após o procedimento, foi capaz de predizer a eficácia da terapia de ressincronização cardíaca, em relação à mortalidade. Não houve correlação entre os parâmetros ecocardiográficos e a melhora clínica de alguns pacientes. / Abstract: Introduction In the cardiac resynchronization therapy is an effective option for patients with advanced heart failure. However, 20 to 30% of patients did not show benefits to this therapy. Clinical criteria, electrocardiography and the echocardiography have been studied in an attempt to select the patients who will benefit from the cardiac resynchronization, and the echocardiogram is a method used in both the selection, as in the evaluation and optimization of this therapy. Objective: The objective of this study is to evaluate the use of echocardiography in the evaluation of patients undergoing cardiac resynchronization therapy for a period of two years. Patients and Methods: We evaluated 20 patients with the implantation of biventricular pacemaker for cardiac resynchronization therapy for over two years, and 16 (80%) males, ranging in age from 27 to 80 years (59.70±12.59 years). The etiology of cardiomyopathy was ischemic in 10 patients (50%), Chagas disease in six (30%) and idiophatic in 4 (20%). Fifteen patients were in functional class III (New York Heart Association) and five in functional class IV at the time of implantation of the pacemaker. We applied the Quality of Life Questionnaire of Minnesota and conducted the test of a six-minute walk to evaluate the clinical conditions of patients. Directed two-dimensional Doppler echocardiography for evaluation of ventricular function, cavity diameters, myocardial performance index, study of interventricular dyssynchrony (eletromechanical delay left ventricle - the right ventricle) and intraventricular (by way dimensional analysis and tissue Doppler), the diastolic function and degree of mitral regurgitation. Ten days after implantation of biventricular pacemaker, was repeated throughout the initial assessment and again after two years. Results: In two years, five patients (25%) were to death, and that these, four had Chagas disease. The average duration of the QRS complex was 154.5±18.48 x 129.0±22.91 x 134.0±24.14 ms, respectively in preoperative, ten days and two years after surgery. There was no statistically significant change in the ejection fraction between preoperative and ten days but there was significant change between periods preoperative and 2 years and 10 days and 2 years. Following ten days, the evaluation of intraventricular dyssynchrony by tissue Doppler and quality of life scores were significantly higher in the group died. Conclusion: The echocardiography is an evolving technology and the parameters evaluated, only the assessment of intraventricular dyssynchrony by Doppler tissue after the procedure was able to predict the effectiveness of the cardiac resynchronization therapy, in relation to mortality. There was no correlation between echocardiographic parameters and clinical improvement in some patients. / Mestrado / Mestre em Cirurgia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/311904
Date12 August 2018
CreatorsVeiga, Viviane Cordeiro, 1976-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Ordinola Rojas, Salomon Soriano, Vieira, Reinaldo Wilson, Abensur, Henry
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Cirurgia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format87 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.003 seconds