Análise de prova de carga em tubulão a céu aberto submetido a esforço horizontal em solo não saturado de diabásio da região de Campinas / Analysis of static load test in the open pipe, subjected to horizontal stress in unsaturated diabasic soil of Campinas

Orientador: David de Carvalho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-21T12:02:47Z (GMT). No. of bitstreams: 1
Kassouf_Roberto_M.pdf: 4587745 bytes, checksum: 67d8f7ab10c6a6a1d4b0e8a2abdfa71e (MD5)
Previous issue date: 2012 / Resumo: O problema de tubulões carregados horizontalmente no topo é freqüente em obras de construção civil e normalmente estes esforços horizontais atuam concomitantemente aos esforços verticais e momentos fletores onde os casos mais freqüentes são as ações dos ventos, torres de transmissão e para energia eólica, obras de arte como pontes e viadutos, muros de arrimo com o empuxo do solo, escavações para subsolo e edificações prediais, havendo uma reduzida bibliografia sobre os parâmetros a serem adotados em projeto. Uma hipótese mais critica é a de tubulões carregados horizontalmente em solos de alta porosidade, não saturados e colapsíveis. Os objetivos desta dissertação são: (1) proporcionar subsídios para o projeto de fundações com carregamento horizontal para tubulões, chamando a atenção para o danoso efeito de uma inundação de um solo colapsível; (2) fornecer valores do coeficiente de reação horizontal (nh), para uma argila siltosa arenosa de alta porosidade, solo de diabásio, comum na região de Campinas, para condição natural de umidade e solo pré-inundado; (3) comparar os valores obtidos com valores de (nh) com os propostos na bibliografia. Para a analise deste problema foi executado um tubulão em maciço de solo de formação de magmáticos básicos, ocorrendo rochas intrusivas básicas (Diabásios) da Formação Serra Geral, que faz parte do Grupo São Bento, característica do Campo Experimental de Fundações da UNICAMP/Campinas, com mais dois tubulões alinhados, estes servindo de reação ao sistema, todos executados a céu aberto e com base alargada, onde foram inseridos no eixo do tubulão a ser analisado, tubos para utilização de inclinomêtro e strain gages. As análises basearam-se nos resultados obtidos nas curvas de cargas versus deslocamento horizontais resultantes no topo e em profundidade através da utilização do inclinômetro / Abstract: The problem of caissons loaded horizontally at the top is common in construction work and normally these horizontal forces act concurrently with the vertical forces and bending moments where the most frequent cases are the actions of the winds, in towers for electric transmission and for wind energy, works of art as bridges and viaducts, retaining walls, underground excavations for buildings and there is a small literature on the parameters to be adopted in the project. One hypothesis, the most critical, is of caissons loaded horizontally in soils of high porosity, unsaturated and collapsible. The objectives of this dissertation are: (1) provide grants for the design of foundations with horizontal loading for caissons, calling attention to the damaging effect of a flood of a collapsible soil, (2) provide values of the coefficient of horizontal reaction (nh) to a sandy silty clay of high porosity, diabase soil, common in the region of Campinas, in the natural moisture content condition and in the pre-inundated soil condition, (3) compare the values obtained with the value (nh) with those proposed in the literature. For the analysis of this problem was carried out an caisson in a soil constituted by magmatic basic intrusive rocks (diabases) of the Serra Geral Formation, which is part of the São Bento Group, characteristic of the Experimental Foundations of Campinas / Campinas, aligned with two other caissons, serving as a reaction to these system, all running in the open and broad based, which were inserted into the pipe to be analyzed on its axis tubes for use with strain gages and inclinometer. The analyzes were based on the results of the load versus displacement curves obtained in the caisson head and in caisson shaft in depth / Mestrado / Geotecnia / Mestre em Engenharia Civil

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258166
Date21 August 2018
CreatorsKassouf, Roberto, 1963-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Carvalho, David de, 1955-, Carvalho, David de, 1931-, Peixoto, Anna Silvia Palcheco, Massad, Faiçao
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format112 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds