The present study deals with the use of fiberglass reinforced polymer bars (GFRP) as a replacement for the common steel of a reinforced concrete circular pile, in order to avoid the corrosion of durability of reinforcing bars and thus improve them. The comparative analysis was carried out between a pile reinforced with GFRP and another with steel, where the ductility was evaluated by obtaining moment-curvature diagram. As a result, said idealized moment-curvature diagrams and ductility indices are presented, concluding the ductility of the section reinforced with GFRP in 20% more than that of steel.
Identifer | oai:union.ndltd.org:PERUUPC/oai:repositorioacademico.upc.edu.pe:10757/651796 |
Date | 28 February 2020 |
Creators | Pichardo, C., Pichardo, C., Tovar, W., Fernandez-Davila, V. I. |
Publisher | Institute of Physics Publishing |
Source Sets | Universidad Peruana de Ciencias Aplicadas (UPC) |
Language | English |
Detected Language | English |
Type | info:eu-repo/semantics/article |
Format | application/pdf |
Rights | info:eu-repo/semantics/openAccess, Attribution-NonCommercial-ShareAlike 4.0 International, http://creativecommons.org/licenses/by-nc-sa/4.0/ |
Relation | IOP Conference Series: Materials Science and Engineering, 1, https://iopscience.iop.org/article/10.1088/1757-899X/758/1/012009, 758 |