The master's thesis deals with district heat exchangers in a thermal steam cycle of combined heat and power plants and with types of condensate cascades in the multilevel heating systems. Calculation of the thermal efficiency of electricity generation is provided for the investigated thermal cycle, which was modified for three different types of cascades. Besides that, a comparison of useful electric power and electricity generation through one year period of working is made. A significant part of the work is devoted to the design of district heat exchangers, including the calculation of thermal power and heat transfer area. Main dimensions are proposed for each exchanger together with a basic drawing.